    User name adev

    Log entry time 18:39:29 on January 28, 2001

    Entry number 55997

    keyword=End_of_Run_1827
    ****************************
     Run Number: 1827
    End of Run Comment:
    RunType=pion_prod,Tar=LH2-15cm,Rad=out,comment=kin5 first production,mode=coincidence,Lmom=1.986,Rmom=-3.039,Ene=5.617,Angle_R=19.122,Angle_L=20.259
    
    
    Time of run = 22.505583 min
    Av. current (on 3x) = 79.278772 uA
    Av. current (on 1x) = 79.093484 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|  106.8027  |  107.0529  |   96.0212
    up-down    (mC)|   -0.3768  |    0.1531  |   -2.4272
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 17100.465 Hz  |    215700.4 /mC  |   22.801 Hz  |  23091356  |   750   |    216205.7 /mC
        2      | 63496.366 Hz  |    800925.2 /mC  |    8.466 Hz  |  85741365  |  7500   |    802801.5 /mC
        3      | 202940.49 Hz  |   2559834.0 /mC  |    8.456 Hz  | 274037650  | 24000   |   2565830.7 /mC
        4      | 75116.627 Hz  |    947499.9 /mC  |   10.016 Hz  | 101432610  |  7500   |    949719.5 /mC
        5      | 338.00057 Hz  |      4263.4 /mC  |  338.001 Hz  |    456414  |     1   |      4273.4 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 327.82976 Hz  |      4135.2 /mC  |  327.830 Hz  | 442680.0  |     1   |      4144.8 /mC
        8    | 1024.0 Hz  |     12916.4 /mC  |    0.016 Hz  |   1382743  | 65535   |     12946.7 /mC
        output                       371.844 Hz
    Av. deadtime from accepted triggers = 0.0399
    Av. deadtime from gated scalers = 0.0940
    Accepted triggers  = 502114.00000
    Rate of Left Arm Pulser for electronic DT  = 10.170809
    Rate of Right Arm Pulser for electronic DT  = 10.170069
    Rate of Left Arm Pulser&trig for electronic DT  = 10.056023
    Rate of Right Arm Pulser&trig for electronic DT  = 10.169328
    Left Arm Electronic DT  = 0.01128586
    Right Arm Electronic DT  = 7.2817301e-05
    Rate of Left Strobe  = 416830.56
    Rate of Right Arm Strobe  = 76058.223
        Signal     |    Charge   (C)   
       upstream    |    0.1066143     
       upstream 3x |    0.1071294     
       upstream 10x|    0.0948076     
      downstream   |    0.1069911   
     downstream 3x |    0.1069763   
     downstream 10x|    0.0972348    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 1827 at Sun Jan 28 18:39:17 EST 2001
    Right Arm D1 momentum                    : 3.039
    Right Arm arm angle                      : 19.1217
    Left Arm D1 momentum                      : 1.98601
    Left Arm arm angle                        : 20.2586
    Tiefenbach Hall A energy                : 5614.91
    Right Arm arm mispointing (HPT)          : -1.6504
    Left Arm arm mispointing (HPT)            : 4.61492
    Right Arm Q1 power supply current        : 2285.19
    Right Arm Q1 momentum                    : 3.03907
    Right Arm Q1 gauss meter                 : -0.05675
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 1307.95
    Right Arm Q2 momentum                    : 3.03915
    Right Arm Q2 gauss meter                 : 0.6865
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 1092.63
    Right Arm D1 momentum                    : 3.039
    Right Arm D1 NMR                         : 1.12774
    Right Arm Q3 power supply current        : 1209.24
    Right Arm Q3 momentum                    : 3.03898
    Right Arm Q3 gauss meter                 : 0.5423
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 1494.19
    Left Arm Q1 momentum                      : 1.98607
    Left Arm Q1 gauss meter                   : 0.12704
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 855.319
    Left Arm Q2 momentum                      : 1.98634
    Left Arm Q2 gauss meter                   : -0.4508
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 672.771
    Left Arm D1 momentum                      : 1.98601
    Left Arm D1 NMR                           : 0.734895
    Left Arm Q3 power supply current          : 790.521
    Left Arm Q3 momentum                      : 1.98564
    Left Arm Q3 gauss meter                   : 0.3949
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 83.6844
    Current on Unser monitor                : 94.9598
    Current on Upstream bcm                 : 83.4077
    Current on Downstream bcm               : 83.9612
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 111.956
    MBSY1c Hall A Beam energy               : 5626.62
    MBSY1c magnet current (amp)             : 235.16
    MBSY1c Bdl                              : 1.40413e+06
    MBSY3c Hall C Beam energy               : 3403.8
    Tiefenbach Hall A energy                : 5614.92
    Tiefenbach Hall C energy                : 3395.58
    Delta(E)/E width (MV_AI_DXWID)          : 0
    IPM1C12.XPOS                            : -0.00250241
    IPM1H04A.XPOS                           : -0.0621847
    IPM1H04A.YPOS                           : 0.138178
    IPM1H04B.XPOS                           : -0.0621072
    IPM1H04B.YPOS                           : 0.0497206
    Right Arm Arm Collimator                 : 0.615088
    Left Arm Arm Collimator                   : 0.61709
     HacR_HPM_LVDT:VALr                     : -1040
     HacR_VPM_LVDT:VALr                     : -194
     HacR_HPE1313A:0_Ch58                   : -0.511719
     HacR_HPE1313A:0_Ch55                   : 22.6074
     HacR_HPE1313A:0_Ch54                   : -0.773926
     HacR_alignROLL                         : -0.293246
     HacR_alignPITCH                        : -0.0407673
     HacR_alignHPT                          : -1.65009
     HacL_HPM_LVDT:VALr                     : -7551
     HacL_VPM_LVDT:VALr                     : 2028
     HacL_HPE1313A:0_Ch58                   : -0.118164
     HacL_HPE1313A:0_Ch55                   : 23.584
     HacL_HPE1313A:0_Ch54                   : -0.166016
     HacL_alignROLL                         : 0.185794
     HacL_alignPITCH                        : -0.139579
     HacL_alignHPT                          : 4.61384
    haBDSPOS                                 : 4.643e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 68
    haL3_Fan_frequency_R                     : 20
    haH2_P_Fill_Target_R                     : 23.32
    haH2_P_Exhaust_R                         : 23.59
    haH2_P_Fill_Bottle_R                     : 23.69
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : 29.97
    haD2_P_Exhaust_R                         : 18.64
    haD2_P_Fill_Bottle_R                     : 36.81
    haD2_DP_Fill_Exhaust_R                   : 0.0765
    haSC200_6_Sensor_1_R                     : 242.11
    haSC200_6_Sensor_2_R                     : 15.04
    haSC200_6_Sensor_3_R                     : 2.97
    haSC200_6_Sensor_4_R                     : 39.71
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 94.98
    haITC502_1_Sensor_3_R                    : 94.98
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19.28
    haITC502_4_Sensor_1_R                    : 93.6
    haITC502_4_Sensor_2_R                    : 19.2
    haITC502_4_Sensor_3_R                    : 21.9
    haITC502_5_Sensor_1_R                    : 85.23
    haITC502_5_Sensor_2_R                    : 83.05
    haITC502_5_Sensor_3_R                    : 266.7
    haITC502_6_Sensor_1_R                    : 99.97
    haITC502_6_Sensor_2_R                    : 99.97
    haITC502_6_Sensor_3_R                    : 27.95
    Right Arm Arm Collimator                 : 0.615088
    Left Arm Arm Collimator                   : 0.61709
    Wien angle                               : 1.37
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : -3.63
    Wien field                               : 0
    Laser attenuation Hall A                 : 573
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : OFF