    User name adev

    Log entry time 01:40:23 on January 29, 2001

    Entry number 56023

    keyword=End_of_Run_1838
    ****************************
     Run Number: 1838
    End of Run Comment:
    RunType=pion_prod,Tar=LH2-15cm,Rad=out,comment=kin5 production,mode=coincidence,Lmom=1.986,Rmom=-3.039,Ene=5.617,Angle_R=19.122,Angle_L=20.259
    
    
    Time of run = 45.362337 min
    Av. current (on 3x) = 58.142471 uA
    Av. current (on 1x) = 58.003479 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|  157.8704  |  158.2487  |  147.1810
    up-down    (mC)|   -0.2832  |    0.4374  |   -3.4111
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 12606.212 Hz  |    216815.9 /mC  |   16.808 Hz  |  34310833  |   750   |    217335.4 /mC
        2      | 47503.546 Hz  |    817019.7 /mC  |    6.334 Hz  | 129292310  |  7500   |    818977.5 /mC
        3      | 150001.18 Hz  |   2579890.1 /mC  |    6.250 Hz  | 408264250  | 24000   |   2586072.2 /mC
        4      | 55745.145 Hz  |    958768.1 /mC  |    7.433 Hz  | 151723800  |  7500   |    961065.5 /mC
        5      | 232.27639 Hz  |      3995.0 /mC  |  232.276 Hz  |    632196  |     1   |      4004.5 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 222.10128 Hz  |      3819.9 /mC  |  222.101 Hz  | 604502.0  |     1   |      3829.1 /mC
        8    | 1024.0 Hz  |     17611.9 /mC  |    0.016 Hz  |   2787062  | 65535   |     17654.1 /mC
        output                       260.095 Hz
    Av. deadtime from accepted triggers = 0.0324
    Av. deadtime from gated scalers = 0.0851
    Accepted triggers  = 707912.00000
    Rate of Left Arm Pulser for electronic DT  = 10.175108
    Rate of Right Arm Pulser for electronic DT  = 10.170331
    Rate of Left Arm Pulser&trig for electronic DT  = 10.097584
    Rate of Right Arm Pulser&trig for electronic DT  = 10.169597
    Left Arm Electronic DT  = 0.0076189788
    Right Arm Electronic DT  = 7.2251725e-05
    Rate of Left Strobe  = 305989.75
    Rate of Right Arm Strobe  = 56482.765
        Signal     |    Charge   (C)   
       upstream    |    0.1577288     
       upstream 3x |    0.1584674     
       upstream 10x|    0.1454755     
      downstream   |    0.1580120   
     downstream 3x |    0.1580300   
     downstream 10x|    0.1488866    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 1838 at Mon Jan 29 01:40:08 EST 2001
    Right Arm D1 momentum                    : 3.039
    Right Arm arm angle                      : 19.1219
    Left Arm D1 momentum                      : 1.98601
    Left Arm arm angle                        : 20.2587
    Tiefenbach Hall A energy                : 5614.91
    Right Arm arm mispointing (HPT)          : -1.67195
    Left Arm arm mispointing (HPT)            : 4.60703
    Right Arm Q1 power supply current        : 2285.19
    Right Arm Q1 momentum                    : 3.03907
    Right Arm Q1 gauss meter                 : -0.05675
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 1307.92
    Right Arm Q2 momentum                    : 3.03908
    Right Arm Q2 gauss meter                 : 0.6866
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 1092.63
    Right Arm D1 momentum                    : 3.039
    Right Arm D1 NMR                         : 1.12774
    Right Arm Q3 power supply current        : 1209.25
    Right Arm Q3 momentum                    : 3.03901
    Right Arm Q3 gauss meter                 : 0.5423
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 1494.11
    Left Arm Q1 momentum                      : 1.98598
    Left Arm Q1 gauss meter                   : 0.12707
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 855.252
    Left Arm Q2 momentum                      : 1.98619
    Left Arm Q2 gauss meter                   : -0.4508
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 672.779
    Left Arm D1 momentum                      : 1.98601
    Left Arm D1 NMR                           : 0.734896
    Left Arm Q3 power supply current          : 790.694
    Left Arm Q3 momentum                      : 1.98608
    Left Arm Q3 gauss meter                   : 0.3949
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 79.9537
    Current on Unser monitor                : 89.8194
    Current on Upstream bcm                 : 80.0304
    Current on Downstream bcm               : 79.877
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 79.8094
    MBSY1c Hall A Beam energy               : 5626.62
    MBSY1c magnet current (amp)             : 235.16
    MBSY1c Bdl                              : 1.40413e+06
    MBSY3c Hall C Beam energy               : 3403.8
    Tiefenbach Hall A energy                : 5614.91
    Tiefenbach Hall C energy                : 3396.15
    Delta(E)/E width (MV_AI_DXWID)          : 0
    IPM1C12.XPOS                            : 0.00282085
    IPM1H04A.XPOS                           : -0.0444522
    IPM1H04A.YPOS                           : 0.129372
    IPM1H04B.XPOS                           : -0.0268672
    IPM1H04B.YPOS                           : 0.0328732
    Right Arm Arm Collimator                 : 0.615088
    Left Arm Arm Collimator                   : 0.617139
     HacR_HPM_LVDT:VALr                     : -1021
     HacR_VPM_LVDT:VALr                     : -204
     HacR_HPE1313A:0_Ch58                   : -0.510742
     HacR_HPE1313A:0_Ch55                   : 22.6562
     HacR_HPE1313A:0_Ch54                   : -0.773438
     HacR_alignROLL                         : -0.292201
     HacR_alignPITCH                        : -0.042181
     HacR_alignHPT                          : -1.67223
     HacL_HPM_LVDT:VALr                     : -7546
     HacL_VPM_LVDT:VALr                     : 2035
     HacL_HPE1313A:0_Ch58                   : -0.118164
     HacL_HPE1313A:0_Ch55                   : 23.3887
     HacL_HPE1313A:0_Ch54                   : -0.165527
     HacL_alignROLL                         : 0.186089
     HacL_alignPITCH                        : -0.13943
     HacL_alignHPT                          : 4.60811
    haBDSPOS                                 : 4.643e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 64.5
    haL3_Fan_frequency_R                     : 20
    haH2_P_Fill_Target_R                     : 22.87
    haH2_P_Exhaust_R                         : 23.17
    haH2_P_Fill_Bottle_R                     : 23.24
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : 29.98
    haD2_P_Exhaust_R                         : 18.33
    haD2_P_Fill_Bottle_R                     : 36.26
    haD2_DP_Fill_Exhaust_R                   : 0.0768
    haSC200_6_Sensor_1_R                     : 241.61
    haSC200_6_Sensor_2_R                     : 14.81
    haSC200_6_Sensor_3_R                     : 2.63
    haSC200_6_Sensor_4_R                     : 39.58
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 94.98
    haITC502_1_Sensor_3_R                    : 94.98
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19.27
    haITC502_4_Sensor_1_R                    : 93.7
    haITC502_4_Sensor_2_R                    : 19.2
    haITC502_4_Sensor_3_R                    : 21.9
    haITC502_5_Sensor_1_R                    : 84.97
    haITC502_5_Sensor_2_R                    : 82.82
    haITC502_5_Sensor_3_R                    : 266.5
    haITC502_6_Sensor_1_R                    : 99.97
    haITC502_6_Sensor_2_R                    : 99.97
    haITC502_6_Sensor_3_R                    : 27.93
    Right Arm Arm Collimator                 : 0.615088
    Left Arm Arm Collimator                   : 0.617041
    Wien angle                               : 1.37
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : -3.63
    Wien field                               : 0
    Laser attenuation Hall A                 : 439
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : OFF