User name adev
Log entry time 03:13:04 on January 29, 2001
Entry number 56042
keyword=Start_Run_1844_RunType=Other,Tar=dum-15cm,Rad=out,comment=kin6
Beginning-of-run EPICS data for Run Number 1844 at Mon Jan 29 03:12:51 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=2,ps2=7500,ps3=20,ps4=7500,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 2285.22
Right Arm Q1 momentum : 3.03912
Right Arm Q1 gauss meter : -0.05675
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 1307.81
Right Arm Q2 momentum : 3.03883
Right Arm Q2 gauss meter : 0.6866
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 1092.63
Right Arm D1 momentum : 3.039
Right Arm D1 NMR : 1.12774
Right Arm Q3 power supply current : 1209.47
Right Arm Q3 momentum : 3.03957
Right Arm Q3 gauss meter : 0.5422
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1452.08
Left Arm Q1 momentum : 1.93011
Left Arm Q1 gauss meter : 0.12353
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 831.059
Left Arm Q2 momentum : 1.93
Left Arm Q2 gauss meter : -0.4381
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 652.587
Left Arm D1 momentum : 1.92999
Left Arm D1 NMR : 0.71418
Left Arm Q3 power supply current : 768.522
Left Arm Q3 momentum : 1.93039
Left Arm Q3 gauss meter : 0.3838
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 29.1144
Current on Unser monitor : 39.2321
Current on Upstream bcm : 28.9464
Current on Downstream bcm : 29.2824
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 29.2129
Beam energy : 5626.62
MBSY1c magnet current (amp) : 235.16
Radiator 5V Linear Supply : 5.00611
Radiator Encoder : 0.156288
haBDSPOS : 1.72635e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 67.5
haL3_Fan_frequency_R : 14.5
haSC200_6_Sensor_1_R : 241.41
haSC200_6_Sensor_2_R : 14.8
haSC200_6_Sensor_3_R : 2.53
haSC200_6_Sensor_4_R : 39.51
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 93.8
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 22
haITC502_5_Sensor_1_R : 85.07
haITC502_5_Sensor_2_R : 82.97
haITC502_5_Sensor_3_R : 269.8
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.07
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.617139
HacR_HPM_LVDT:VALr : -971
HacR_VPM_LVDT:VALr : -187
HacR_HPE1313A:0_Ch58 : -0.506836
HacR_HPE1313A:0_Ch55 : 22.6074
HacR_HPE1313A:0_Ch54 : -0.760254
HacR_alignROLL : -0.27895
HacR_alignPITCH : -0.0461539
HacR_alignHPT : -1.73435
HacL_HPM_LVDT:VALr : -7139
HacL_VPM_LVDT:VALr : 1725
HacL_HPE1313A:0_Ch58 : -0.171387
HacL_HPE1313A:0_Ch55 : 23.3887
HacL_HPE1313A:0_Ch54 : 0.00927734
HacL_alignROLL : 0.349993
HacL_alignPITCH : -0.112169
HacL_alignHPT : 4.07579
Right Arm Angle Floor Angle : 19
Right Arm Angle Vernier : -15
Right Arm Scattering Angle : 19.1223
Left Arm Angle Floor Angle : 15
Left Arm Angle Vernier : -26
Left Arm Scattering Angle : 14.6435
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 241
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88