    User name adev

    Log entry time 03:33:14 on January 29, 2001

    Entry number 56050

    keyword=End_of_Run_1847
    ****************************
     Run Number: 1847
    End of Run Comment:
    RunType=Other,Tar=dum-15cm,Rad=out,comment=kin6 dummy,mode=coincidence,Lmom=1.93,Rmom=-3.039,Ene=5.617,Angle_R=19.122,Angle_L=14.644
    
    
    Time of run = 5.8078613 min
    Av. current (on 3x) = 24.182166 uA
    Av. current (on 1x) = 24.115877 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|    8.4037  |    8.4268  |    8.4388
    up-down    (mC)|   -0.0020  |    0.0178  |    0.0303
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 1623.5724 Hz  |     67139.2 /mC  |  811.786 Hz  |    565769  |     2   |     67323.8 /mC
        2      | 10634.836 Hz  |    439780.1 /mC  |    1.418 Hz  |   3705939  |  7500   |    440989.0 /mC
        3      | 48136.448 Hz  |   1990576.4 /mC  | 2406.822 Hz  |  16774189  |    20   |   1996048.1 /mC
        4      | 15664.802 Hz  |    647783.3 /mC  |    2.089 Hz  |   5458740  |  7500   |    649563.9 /mC
        5      | 18.632791 Hz  |       770.5 /mC  |   18.633 Hz  |      6493  |     1   |       772.6 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 8.471277 Hz  |       350.3 /mC  |    8.471 Hz  | 2952.0001  |     1   |       351.3 /mC
        8    | 1024.0 Hz  |     42345.3 /mC  |    0.016 Hz  |    356835  | 65535   |     42461.7 /mC
        output                      2199.846 Hz
    Av. deadtime from accepted triggers = 0.3190
    Av. deadtime from gated scalers = 0.5106
    Accepted triggers  = 766584.00000
    Rate of Left Arm Pulser for electronic DT  = 10.161514
    Rate of Right Arm Pulser for electronic DT  = 10.132818
    Rate of Left Arm Pulser&trig for electronic DT  = 10.147166
    Rate of Right Arm Pulser&trig for electronic DT  = 10.132818
    Left Arm Electronic DT  = 0.0014120305
    Right Arm Electronic DT  = 0.0
    Rate of Left Strobe  = 95390.271
    Rate of Right Arm Strobe  = 11516.101
        Signal     |    Charge   (C)   
       upstream    |    0.0084027     
       upstream 3x |    0.0084357     
       upstream 10x|    0.0084539     
      downstream   |    0.0084047   
     downstream 3x |    0.0084179   
     downstream 10x|    0.0084236    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 1847 at Mon Jan 29 03:33:01 EST 2001
    Right Arm D1 momentum                    : 3.039
    Right Arm arm angle                      : 19.1223
    Left Arm D1 momentum                      : 1.92999
    Left Arm arm angle                        : 14.6436
    Tiefenbach Hall A energy                : 5614.92
    Right Arm arm mispointing (HPT)          : -1.73687
    Left Arm arm mispointing (HPT)            : 4.07084
    Right Arm Q1 power supply current        : 2285.08
    Right Arm Q1 momentum                    : 3.03893
    Right Arm Q1 gauss meter                 : -0.05676
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 1307.94
    Right Arm Q2 momentum                    : 3.03911
    Right Arm Q2 gauss meter                 : 0.6866
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 1092.62
    Right Arm D1 momentum                    : 3.039
    Right Arm D1 NMR                         : 1.12774
    Right Arm Q3 power supply current        : 1209.01
    Right Arm Q3 momentum                    : 3.03842
    Right Arm Q3 gauss meter                 : 0.5422
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 1452.08
    Left Arm Q1 momentum                      : 1.93011
    Left Arm Q1 gauss meter                   : 0.12349
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 831.025
    Left Arm Q2 momentum                      : 1.92992
    Left Arm Q2 gauss meter                   : -0.4382
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 652.589
    Left Arm D1 momentum                      : 1.92999
    Left Arm D1 NMR                           : 0.714179
    Left Arm Q3 power supply current          : 768.278
    Left Arm Q3 momentum                      : 1.92977
    Left Arm Q3 gauss meter                   : 0.3837
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 29.0317
    Current on Unser monitor                : 40.5279
    Current on Upstream bcm                 : 28.997
    Current on Downstream bcm               : 29.0663
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 29.26
    MBSY1c Hall A Beam energy               : 5626.62
    MBSY1c magnet current (amp)             : 235.16
    MBSY1c Bdl                              : 1.40413e+06
    MBSY3c Hall C Beam energy               : 3403.8
    Tiefenbach Hall A energy                : 5614.9
    Tiefenbach Hall C energy                : 3396.15
    Delta(E)/E width (MV_AI_DXWID)          : 0
    IPM1C12.XPOS                            : 0.00405762
    IPM1H04A.XPOS                           : -0.135333
    IPM1H04A.YPOS                           : 0.0699876
    IPM1H04B.XPOS                           : -0.0915506
    IPM1H04B.YPOS                           : 0.00909726
    Right Arm Arm Collimator                 : 0.615088
    Left Arm Arm Collimator                   : 0.617041
     HacR_HPM_LVDT:VALr                     : -970
     HacR_VPM_LVDT:VALr                     : -185
     HacR_HPE1313A:0_Ch58                   : -0.506348
     HacR_HPE1313A:0_Ch55                   : 22.6074
     HacR_HPE1313A:0_Ch54                   : -0.759766
     HacR_alignROLL                         : -0.278457
     HacR_alignPITCH                        : -0.0466027
     HacR_alignHPT                          : -1.73687
     HacL_HPM_LVDT:VALr                     : -7137
     HacL_VPM_LVDT:VALr                     : 1726
     HacL_HPE1313A:0_Ch58                   : -0.171875
     HacL_HPE1313A:0_Ch55                   : 23.3887
     HacL_HPE1313A:0_Ch54                   : 0.00830078
     HacL_alignROLL                         : 0.349605
     HacL_alignPITCH                        : -0.11137
     HacL_alignHPT                          : 4.07151
    haBDSPOS                                 : 1.72635e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 66
    haL3_Fan_frequency_R                     : 15
    haH2_P_Fill_Target_R                     : 23
    haH2_P_Exhaust_R                         : 23.31
    haH2_P_Fill_Bottle_R                     : 23.36
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : 30
    haD2_P_Exhaust_R                         : 18.44
    haD2_P_Fill_Bottle_R                     : 36.45
    haD2_DP_Fill_Exhaust_R                   : 0.077
    haSC200_6_Sensor_1_R                     : 241.38
    haSC200_6_Sensor_2_R                     : 14.81
    haSC200_6_Sensor_3_R                     : 2.56
    haSC200_6_Sensor_4_R                     : 39.51
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 94.98
    haITC502_1_Sensor_3_R                    : 94.98
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19.07
    haITC502_4_Sensor_1_R                    : 93.8
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 22
    haITC502_5_Sensor_1_R                    : 85.1
    haITC502_5_Sensor_2_R                    : 82.98
    haITC502_5_Sensor_3_R                    : 269.7
    haITC502_6_Sensor_1_R                    : 99.97
    haITC502_6_Sensor_2_R                    : 99.97
    haITC502_6_Sensor_3_R                    : 28.07
    Right Arm Arm Collimator                 : 0.615039
    Left Arm Arm Collimator                   : 0.617041
    Wien angle                               : 1.37
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : -3.63
    Wien field                               : 0
    Laser attenuation Hall A                 : 240
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : OFF