    User name adev

    Log entry time 12:24:29 on January 29, 2001

    Entry number 56128

    keyword=End_of_Run_1872
    ****************************
     Run Number: 1872
    End of Run Comment:
    RunType=pion_prod,Tar=LH2-15cm,Rad=out,comment=kin9 15 cm LH2 data at kin 9,mode=coincidence,Lmom=1.89,Rmom=-3.039,Ene=5.617,Angle_R=19.122,Angle_L=12.521
    
    
    Time of run = 16.199154 min
    Av. current (on 3x) = 55.433349 uA
    Av. current (on 1x) = 55.302786 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|   53.7515  |   53.8784  |   49.0103
    up-down    (mC)|   -0.0976  |    0.1452  |   -1.1646
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 12021.652 Hz  |    216866.8 /mC  |   16.029 Hz  |  11684435  |   750   |    217378.8 /mC
        2      | 44394.191 Hz  |    800857.1 /mC  |    5.919 Hz  |  43148899  |  7500   |    802747.8 /mC
        3      | 583969.07 Hz  |  10534616.0 /mC  |   24.332 Hz  | 567588280  | 24000   |  10559487.0 /mC
        4      | 98964.092 Hz  |   1785280.8 /mC  |   13.195 Hz  |  96188072  |  7500   |   1789495.6 /mC
        5      | 856.85546 Hz  |     15457.4 /mC  |  856.855 Hz  |    832820  |     1   |     15493.9 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 846.68209 Hz  |     15273.9 /mC  |  846.682 Hz  | 822932.0  |     1   |     15309.9 /mC
        8    | 1024.0 Hz  |     18472.6 /mC  |    0.016 Hz  |    995276  | 65535   |     18516.2 /mC
        output                       779.812 Hz
    Av. deadtime from accepted triggers = 0.1479
    Av. deadtime from gated scalers = 0.1918
    Accepted triggers  = 757938.00000
    Rate of Left Arm Pulser for electronic DT  = 10.173371
    Rate of Right Arm Pulser for electronic DT  = 10.173371
    Rate of Left Arm Pulser&trig for electronic DT  = 9.8287028
    Rate of Right Arm Pulser&trig for electronic DT  = 10.172342
    Left Arm Electronic DT  = 0.03387945
    Right Arm Electronic DT  = 0.00010113269
    Rate of Left Strobe  = 901254.58
    Rate of Right Arm Strobe  = 52830.334
        Signal     |    Charge   (C)   
       upstream    |    0.0537027     
       upstream 3x |    0.0539510     
       upstream 10x|    0.0484280     
      downstream   |    0.0538003   
     downstream 3x |    0.0538058   
     downstream 10x|    0.0495926    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 1872 at Mon Jan 29 12:24:15 EST 2001
    Right Arm D1 momentum                    : 3.039
    Right Arm arm angle                      : 19.1223
    Left Arm D1 momentum                      : 1.89
    Left Arm arm angle                        : 12.5215
    Tiefenbach Hall A energy                : 5614.92
    Right Arm arm mispointing (HPT)          : -1.73497
    Left Arm arm mispointing (HPT)            : 3.9254
    Right Arm Q1 power supply current        : 2285.08
    Right Arm Q1 momentum                    : 3.03893
    Right Arm Q1 gauss meter                 : -0.05674
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 1307.81
    Right Arm Q2 momentum                    : 3.03883
    Right Arm Q2 gauss meter                 : 0.6865
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 1092.62
    Right Arm D1 momentum                    : 3.039
    Right Arm D1 NMR                         : 1.12774
    Right Arm Q3 power supply current        : 1208.97
    Right Arm Q3 momentum                    : 3.03832
    Right Arm Q3 gauss meter                 : 0.5422
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 1421.98
    Left Arm Q1 momentum                      : 1.8901
    Left Arm Q1 gauss meter                   : 0.12091
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 813.757
    Left Arm Q2 momentum                      : 1.89
    Left Arm Q2 gauss meter                   : -0.4291
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 638.221
    Left Arm D1 momentum                      : 1.89
    Left Arm D1 NMR                           : 0.699389
    Left Arm Q3 power supply current          : 752.355
    Left Arm Q3 momentum                      : 1.88978
    Left Arm Q3 gauss meter                   : 0.3759
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 82.7378
    Current on Unser monitor                : 92.606
    Current on Upstream bcm                 : 82.6803
    Current on Downstream bcm               : 82.7953
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 82.5475
    MBSY1c Hall A Beam energy               : 5626.62
    MBSY1c magnet current (amp)             : 235.16
    MBSY1c Bdl                              : 1.40413e+06
    MBSY3c Hall C Beam energy               : 3403.8
    Tiefenbach Hall A energy                : 5614.91
    Tiefenbach Hall C energy                : 3396.15
    Delta(E)/E width (MV_AI_DXWID)          : 0
    IPM1C12.XPOS                            : -0.00412518
    IPM1H04A.XPOS                           : -0.108757
    IPM1H04A.YPOS                           : 0.122081
    IPM1H04B.XPOS                           : -0.113656
    IPM1H04B.YPOS                           : 0.0283522
    Right Arm Arm Collimator                 : 0.615088
    Left Arm Arm Collimator                   : 0.61709
     HacR_HPM_LVDT:VALr                     : -979
     HacR_VPM_LVDT:VALr                     : -220
     HacR_HPE1313A:0_Ch58                   : -0.503418
     HacR_HPE1313A:0_Ch55                   : 22.6074
     HacR_HPE1313A:0_Ch54                   : -0.749512
     HacR_alignROLL                         : -0.268105
     HacR_alignPITCH                        : -0.049296
     HacR_alignHPT                          : -1.7327
     HacL_HPM_LVDT:VALr                     : -7026
     HacL_VPM_LVDT:VALr                     : 1298
     HacL_HPE1313A:0_Ch58                   : -0.20459
     HacL_HPE1313A:0_Ch55                   : 23.4375
     HacL_HPE1313A:0_Ch54                   : 0.0595703
     HacL_alignROLL                         : 0.39747
     HacL_alignPITCH                        : -0.0825558
     HacL_alignHPT                          : 3.92674
    haBDSPOS                                 : 4.643e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 67.5
    haL3_Fan_frequency_R                     : 15
    haH2_P_Fill_Target_R                     : 24.19
    haH2_P_Exhaust_R                         : 24.51
    haH2_P_Fill_Bottle_R                     : 24.54
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : 29.92
    haD2_P_Exhaust_R                         : 19.41
    haD2_P_Fill_Bottle_R                     : 38.39
    haD2_DP_Fill_Exhaust_R                   : 0.0767
    haSC200_6_Sensor_1_R                     : 241.71
    haSC200_6_Sensor_2_R                     : 14.91
    haSC200_6_Sensor_3_R                     : 2.66
    haSC200_6_Sensor_4_R                     : 39.63
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 94.98
    haITC502_1_Sensor_3_R                    : 94.98
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19.28
    haITC502_4_Sensor_1_R                    : 94
    haITC502_4_Sensor_2_R                    : 19.2
    haITC502_4_Sensor_3_R                    : 21.9
    haITC502_5_Sensor_1_R                    : 85.32
    haITC502_5_Sensor_2_R                    : 83.18
    haITC502_5_Sensor_3_R                    : 266.5
    haITC502_6_Sensor_1_R                    : 99.97
    haITC502_6_Sensor_2_R                    : 99.97
    haITC502_6_Sensor_3_R                    : 27.93
    Right Arm Arm Collimator                 : 0.615039
    Left Arm Arm Collimator                   : 0.617041
    Wien angle                               : 1.37
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : -3.63
    Wien field                               : 0
    Laser attenuation Hall A                 : 469
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : OFF