    User name adev

    Log entry time 23:49:47 on January 31, 2001

    Entry number 56213

    keyword=Start_Run_1908_RunType=Cosmic,Tar=absence,Rad=out,comment=with_ped,mode=coincidence,Lmom=2.521,Rmom=-2.608,Ene=5.615,Angle_R=21.005,Angle_L=16.005
    Beginning-of-run EPICS data for Run Number 1908 at Wed Jan 31 23:49:38 EST 2001
    ; (Integer!) prescale factors for runs.
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 and T4 to measure efficiency
    ;
    ps1=1,ps2=7500,ps3=1,ps4=7500,ps5=1,ps6=65535,ps7=65535,ps8=65535
    
    
    Right Arm Q1 power supply current        : 0
    Right Arm Q1 momentum                    : 0
    Right Arm Q1 gauss meter                 : 7.5e-06
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 0.16977
    Right Arm Q2 momentum                    : 0.000394477
    Right Arm Q2 gauss meter                 : 0.0005336
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 1.64348
    Right Arm D1 momentum                    : 0
    Right Arm D1 NMR                         : 0.339002
    Right Arm Q3 power supply current        : 0.0485766
    Right Arm Q3 momentum                    : 0.00012208
    Right Arm Q3 gauss meter                 : -0.0001943
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 0
    Left Arm Q1 momentum                      : 0
    Left Arm Q1 gauss meter                   : 0.0003449
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 0.0332501
    Left Arm Q2 momentum                      : 7.72182e-05
    Left Arm Q2 gauss meter                   : -0.0007732
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 0.137834
    Left Arm D1 momentum                      : 0
    Left Arm D1 NMR                           : 0.162646
    Left Arm Q3 power supply current          : 1.74136
    Left Arm Q3 momentum                      : 0.00481389
    Left Arm Q3 gauss meter                   : 0.0016573
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 0.0450698
    Current on Unser monitor                : 10.1567
    Current on Upstream bcm                 : 0.0571544
    Current on Downstream bcm               : 0.0329852
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 0.00142881
    Beam energy                             : 5626.62
    MBSY1c magnet current (amp)             : 0.0377197
     Radiator 5V Linear Supply              : 4.95971
     Radiator Encoder                       : 0.144078
    haBDSPOS                                 : 190450
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 0
    haL3_Fan_frequency_R                     : 0
    haSC200_6_Sensor_1_R                     : 241.43
    haSC200_6_Sensor_2_R                     : 25.03
    haSC200_6_Sensor_3_R                     : 2.61
    haSC200_6_Sensor_4_R                     : 39.66
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 94.98
    haITC502_1_Sensor_3_R                    : 94.98
    haITC502_4_Sensor_1_R                    : 94.7
    haITC502_4_Sensor_2_R                    : 34.3
    haITC502_4_Sensor_3_R                    : 46.1
    haITC502_5_Sensor_1_R                    : 85.64
    haITC502_5_Sensor_2_R                    : 83.7
    haITC502_5_Sensor_3_R                    : 266
    haITC502_6_Sensor_1_R                    : 99.97
    haITC502_6_Sensor_2_R                    : 99.97
    haITC502_6_Sensor_3_R                    : 27.84
    Right Arm Arm Collimator                 : 0.615039
    Left Arm Arm Collimator                   : 0.616992
     HacR_HPM_LVDT:VALr                     : -3861
     HacR_VPM_LVDT:VALr                     : -191
     HacR_HPE1313A:0_Ch58                   : -0.540039
     HacR_HPE1313A:0_Ch55                   : 22.4609
     HacR_HPE1313A:0_Ch54                   : -0.737305
     HacR_alignROLL                         : -0.256453
     HacR_alignPITCH                        : -0.01588
     HacR_alignHPT                          : 1.4867
     HacL_HPM_LVDT:VALr                     : -7269
     HacL_VPM_LVDT:VALr                     : Inf
     HacL_HPE1313A:0_Ch58                   : -0.163086
     HacL_HPE1313A:0_Ch55                   : 23.291
     HacL_HPE1313A:0_Ch54                   : 0.0141602
     HacL_alignROLL                         : 0.35464
     HacL_alignPITCH                        : -0.119591
     HacL_alignHPT                          : 4.21882
    Right Arm Angle Floor Angle               : 21
    Right Arm Angle Vernier                   : -32
    Right Arm Scattering Angle                : 21.0025
    Left Arm Angle Floor Angle                 : 16.5
    Left Arm Angle Vernier                     : -49.8
    Left Arm Scattering Angle                  : 16.0054
    Wien angle                               : 1.37
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 3.18799
    Wien field                               : 0
    Laser attenuation Hall A                 : 260
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : OFF
    Survey X offset bpmA                      : -0.32
    Survey Y offset bpmA                      : -0.35
    Survey X offset bpmB                      : -0.05
    Survey Y offset bpmB                      : -0.88