User name adev
Log entry time 20:18:20 on February 13, 2001
Entry number 56235
keyword=Start_Run_1914_RunType=Cosmic,Tar=absence,Rad=out,comment=with_ped,mode=coincidence,Lmom=2.521,Rmom=-2.608,Ene=5.615,Angle_R=21.005,Angle_L=16.005
Beginning-of-run EPICS data for Run Number 1914 at Tue Feb 13 20:17:49 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=7500,ps3=1,ps4=7500,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0
Right Arm Q1 gauss meter : 3.49e-05
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 0.303612
Right Arm Q2 momentum : 0.000705471
Right Arm Q2 gauss meter : -0.0002924
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 1.64377
Right Arm D1 momentum : 0
Right Arm D1 NMR : 0.468649
Right Arm Q3 power supply current : 0.00978378
Right Arm Q3 momentum : 2.4588e-05
Right Arm Q3 gauss meter : -0.0001974
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 0
Left Arm Q1 momentum : 0
Left Arm Q1 gauss meter : 0.0003524
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : -0.00036296
Left Arm Q2 momentum : -8.42918e-07
Left Arm Q2 gauss meter : -0.0007642
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : -0.000338729
Left Arm D1 momentum : 0
Left Arm D1 NMR : 0.455834
Left Arm Q3 power supply current : 1.77982
Left Arm Q3 momentum : 0.00447059
Left Arm Q3 gauss meter : 0.0016323
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 0.0463601
Current on Unser monitor : 11.4565
Current on Upstream bcm : 0.0582933
Current on Downstream bcm : 0.0344269
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 1.00127e-05
Beam energy : 5626.62
MBSY1c magnet current (amp) : 235.16
Radiator 5V Linear Supply : 5.02564
Radiator Encoder : 0.14652
haBDSPOS :
haL1_Fan_frequency_R :
haL2_Fan_frequency_R :
haL3_Fan_frequency_R :
haSC200_6_Sensor_1_R :
haSC200_6_Sensor_2_R :
haSC200_6_Sensor_3_R :
haSC200_6_Sensor_4_R :
haHe_Omega_DPG_Sensor_R :
haITC502_1_Sensor_1_R :
haITC502_1_Sensor_2_R :
haITC502_1_Sensor_3_R :
haITC502_4_Sensor_1_R :
haITC502_4_Sensor_2_R :
haITC502_4_Sensor_3_R :
haITC502_5_Sensor_1_R :
haITC502_5_Sensor_2_R :
haITC502_5_Sensor_3_R :
haITC502_6_Sensor_1_R :
haITC502_6_Sensor_2_R :
haITC502_6_Sensor_3_R :
Right Arm Arm Collimator : 0.614941
Left Arm Arm Collimator : 0.616943
HacR_HPM_LVDT:VALr : -3980
HacR_VPM_LVDT:VALr : 77
HacR_HPE1313A:0_Ch58 : -0.536133
HacR_HPE1313A:0_Ch55 : 22.3633
HacR_HPE1313A:0_Ch54 : -0.772949
HacR_alignROLL : -0.292063
HacR_alignPITCH : -0.0188889
HacR_alignHPT : 1.6148
HacL_HPM_LVDT:VALr : -8146
HacL_VPM_LVDT:VALr : Inf
HacL_HPE1313A:0_Ch58 : -0.193848
HacL_HPE1313A:0_Ch55 : 23.3398
HacL_HPE1313A:0_Ch54 : -0.255371
HacL_alignROLL : 0.106229
HacL_alignPITCH : -0.0715393
HacL_alignHPT : 5.32021
Right Arm Angle Floor Angle : 25
Right Arm Angle Vernier : -25.5
Right Arm Scattering Angle : 25.0391
Left Arm Angle Floor Angle : 39.5
Left Arm Angle Vernier : 32.8
Left Arm Scattering Angle : 39.474
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 600
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88