    User name adev

    Log entry time 19:16:05 on February 19, 2001

    Entry number 56412

    keyword=End_of_Run_1973
    ****************************
     Run Number: 1973
    End of Run Comment:
    RunType=pion_prod,Tar=LD2-15cm,Rad=4,comment=sing9,mode=singles,Lmom=1.438,Rmom=-1.438,Ene=2.558,Angle_R=43.155,Angle_L=43.159
    
    Time of run = 8.051123 min
    Av. current (on 3x) = 11.227626 uA
    Av. current (on 1x) = 11.207753 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|    5.4141  |    5.4237  |    5.4354
    up-down    (mC)|   -0.0078  |   -0.0229  |   -0.0108
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 355.10781 Hz  |     31628.0 /mC  |  355.108 Hz  |    171541  |     1   |     31684.1 /mC
        2      | 18168.19 Hz  |   1618168.4 /mC  |    1.817 Hz  |   8776460  | 10000   |   1621037.7 /mC
        3      | 1730.802 Hz  |    154155.6 /mC  | 1730.802 Hz  |    836094  |     1   |    154429.0 /mC
        4      | 18693.452 Hz  |   1664951.4 /mC  |    1.869 Hz  |   9030197  | 10000   |   1667903.6 /mC
        5      | 11.106111 Hz  |       989.2 /mC  |   11.106 Hz  |      5365  |     1   |       990.9 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | -9.265788 Hz  |      -825.3 /mC  |   -9.266 Hz  | -4475.9999  |     1   |      -826.7 /mC
        8    | 1024.0 Hz  |     91203.6 /mC  |    0.016 Hz  |    494661  | 65535   |     91365.3 /mC
        output                      1514.074 Hz
    Av. deadtime from accepted triggers = 0.2716
    Av. deadtime from gated scalers = 0.2817
    Accepted triggers  = 731400.00000
    Rate of Left Arm Pulser for electronic DT  = 20.371899
    Rate of Right Arm Pulser for electronic DT  = 10.164214
    Rate of Left Arm Pulser&trig for electronic DT  = 10.184915
    Rate of Right Arm Pulser&trig for electronic DT  = 10.164214
    Left Arm Electronic DT  = 0.50005081
    Right Arm Electronic DT  = 0.0
    Rate of Left Strobe  = 31339.214
    Rate of Right Arm Strobe  = 18428.682
        Signal     |    Charge   (C)   
       upstream    |    0.0054102     
       upstream 3x |    0.0054122     
       upstream 10x|    0.0054300     
      downstream   |    0.0054180   
     downstream 3x |    0.0054351   
     downstream 10x|    0.0054408    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 1973 at Mon Feb 19 19:15:55 EST 2001
    Right Arm D1 momentum                    : 1.438
    Right Arm arm angle                      : 43.1592
    Left Arm D1 momentum                      : 1.43799
    Left Arm arm angle                        : 43.155
    Tiefenbach Hall A energy                : 2560.55
    Right Arm arm mispointing (HPT)          : 2.60167
    Left Arm arm mispointing (HPT)            : 3.83019
    Right Arm Q1 power supply current        : 1081.26
    Right Arm Q1 momentum                    : 1.43796
    Right Arm Q1 gauss meter                 : -0.02697
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 619.065
    Right Arm Q2 momentum                    : 1.43846
    Right Arm Q2 gauss meter                 : 0.3253
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 492.006
    Right Arm D1 momentum                    : 1.438
    Right Arm D1 NMR                         : 0.533624
    Right Arm Q3 power supply current        : 572.012
    Right Arm Q3 momentum                    : 1.43754
    Right Arm Q3 gauss meter                 : 0.2565
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 1081.78
    Left Arm Q1 momentum                      : 1.4379
    Left Arm Q1 gauss meter                   : 0.09216
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 619.226
    Left Arm Q2 momentum                      : 1.43805
    Left Arm Q2 gauss meter                   : -0.3266
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 481.914
    Left Arm D1 momentum                      : 1.43799
    Left Arm D1 NMR                           : 0.532233
    Left Arm Q3 power supply current          : 572.445
    Left Arm Q3 momentum                      : 1.43788
    Left Arm Q3 gauss meter                   : 0.286
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 11.2594
    Current on Unser monitor                : 22.779
    Current on Upstream bcm                 : 11.1046
    Current on Downstream bcm               : 11.4141
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 0.193486
    MBSY1c Hall A Beam energy               : 2564.25
    MBSY1c magnet current (amp)             : 106.728
    MBSY1c Bdl                              : 639912
    MBSY3c Hall C Beam energy               : 3407.56
    Tiefenbach Hall A energy                : 2560.55
    Tiefenbach Hall C energy                : 3398.64
    Delta(E)/E width (MV_AI_DXWID)          : 0
    IPM1C12.XPOS                            : 0.00941047
    IPM1H04A.XPOS                           : 0.0746857
    IPM1H04A.YPOS                           : 0.189646
    IPM1H04B.XPOS                           : -0.0433925
    IPM1H04B.YPOS                           : 0.0167896
    Right Arm Arm Collimator                 : 0.614941
    Left Arm Arm Collimator                   : 0.616992
     HacR_HPM_LVDT:VALr                     : -4816
     HacR_VPM_LVDT:VALr                     : 657
     HacR_HPE1313A:0_Ch58                   : -0.532227
     HacR_HPE1313A:0_Ch55                   : 22.5586
     HacR_HPE1313A:0_Ch54                   : -0.910156
     HacR_alignROLL                         : -0.430347
     HacR_alignPITCH                        : -0.0222969
     HacR_alignHPT                          : 2.60167
     HacL_HPM_LVDT:VALr                     : -6806
     HacL_VPM_LVDT:VALr                     : -360
     HacL_HPE1313A:0_Ch58                   : -0.233398
     HacL_HPE1313A:0_Ch55                   : 23.3398
     HacL_HPE1313A:0_Ch54                   : -0.277832
     HacL_alignROLL                         : 0.0864236
     HacL_alignPITCH                        : -0.0362503
     HacL_alignHPT                          : 3.83023
    haBDSPOS                                 : 3.10127e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 25
    haL3_Fan_frequency_R                     : 37
    haH2_P_Fill_Target_R                     : 22.11
    haH2_P_Exhaust_R                         : 22.55
    haH2_P_Fill_Bottle_R                     : 22.43
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : 29.99
    haD2_P_Exhaust_R                         : 18.04
    haD2_P_Fill_Bottle_R                     : 35.66
    haD2_DP_Fill_Exhaust_R                   : 0.0772
    haSC200_6_Sensor_1_R                     : 241.86
    haSC200_6_Sensor_2_R                     : 42.48
    haSC200_6_Sensor_3_R                     : 2.69
    haSC200_6_Sensor_4_R                     : 40.06
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 94.98
    haITC502_1_Sensor_3_R                    : 94.98
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19.03
    haITC502_4_Sensor_1_R                    : 143.3
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 22
    haITC502_5_Sensor_1_R                    : 0
    haITC502_5_Sensor_2_R                    : 0
    haITC502_5_Sensor_3_R                    : 0
    haITC502_6_Sensor_1_R                    : 0
    haITC502_6_Sensor_2_R                    : 0
    haITC502_6_Sensor_3_R                    : 0
    Right Arm Arm Collimator                 : 0.614941
    Left Arm Arm Collimator                   : 0.616943
    Wien angle                               : 24.1959
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 527.39
    Wien field                               : 15.34
    Laser attenuation Hall A                 : 129
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : OFF