At the start of the shift waited for completion of kinematic change to
singles 9. Noticed the Right Dipole didn't lock at set value.
At 8:300 came the news that beam will be unavalaible for at least 4 hours
due to accelerator work for Hall C.
The problem with the Dipole turned out to be serious. The power supply
controller was locked. Aksed for acces to the hall.
Marc Stevens started working on the problem.
After gaining manual controll of the power supply, the dipole had to be
ramped down.
13:00 field zero. Access to reload controller software
14:00 asked for sweep and closing of the hall
15:00 Hall is in beam permit magnet is ready.
checked BeO target; spot ok up 0.4 and left 0.1 mm
Finally we started at
1545 Run 2079