• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 21:47:19 on February 21, 2001

    Entry number 56699

    keyword=End_of_Run_2096
    ****************************
     Run Number: 2096
    End of Run Comment:
    RunType=pion_prod,Tar=LH2-15cm,Rad=6,comment=sing8,mode=singles,Lmom=-1.974,Rmom=1.974,Ene=2.558,Angle_R=31.02,Angle_L=31.02
    
    
    Time of run = 16.630778 min
    Av. current (on 3x) = 14.297788 uA
    Av. current (on 1x) = 14.27113 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|   14.2404  |   14.2670  |   14.2943
    up-down    (mC)|   -0.0537  |   -0.0645  |   -0.0373
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 3378.978 Hz  |    236328.7 /mC  |  844.745 Hz  |   3371702  |     4   |    236770.2 /mC
        2      | 29126.831 Hz  |   2037156.5 /mC  |    4.161 Hz  |  29064112  |  7000   |   2040961.8 /mC
        3      | 1049.0239 Hz  |     73369.7 /mC  |  262.256 Hz  |   1046765  |     4   |     73506.7 /mC
        4      | 29266.945 Hz  |   2046956.2 /mC  |    5.853 Hz  |  29203924  |  5000   |   2050779.8 /mC
        5      | 10.529674 Hz  |       736.5 /mC  |   10.530 Hz  |     10507  |     1   |       737.8 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | -9.831169 Hz  |      -687.6 /mC  |   -9.831 Hz  | -9809.9996  |     1   |      -688.9 /mC
        8    | 1024.0 Hz  |     71619.5 /mC  |    0.016 Hz  |   1021795  | 65535   |     71753.3 /mC
        output                      1006.364 Hz
    Av. deadtime from accepted triggers = 0.1033
    Av. deadtime from gated scalers = 0.2536
    Accepted triggers  = 1004197.00000
    Rate of Left Arm Pulser for electronic DT  = 20.360843
    Rate of Right Arm Pulser for electronic DT  = 10.167895
    Rate of Left Arm Pulser&trig for electronic DT  = 10.177916
    Rate of Right Arm Pulser&trig for electronic DT  = 10.167895
    Left Arm Electronic DT  = 0.50012305
    Right Arm Electronic DT  = 0.0
    Rate of Left Strobe  = 46074.531
    Rate of Right Arm Strobe  = 31964.62
        Signal     |    Charge   (C)   
       upstream    |    0.0142136     
       upstream 3x |    0.0142348     
       upstream 10x|    0.0142757     
      downstream   |    0.0142673   
     downstream 3x |    0.0142993   
     downstream 10x|    0.0143130    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 2096 at Wed Feb 21 21:46:57 EST 2001
    Right Arm D1 momentum                    : 1.794
    Right Arm arm angle                      : 43.1909
    Left Arm D1 momentum                      : 1.79401
    Left Arm arm angle                        : 42.4335
    Tiefenbach Hall A energy                : 2560.55
    Right Arm arm mispointing (HPT)          : -1.9506
    Left Arm arm mispointing (HPT)            : 4.19872
    Right Arm Q1 power supply current        : 1348.97
    Right Arm Q1 momentum                    : 1.794
    Right Arm Q1 gauss meter                 : 0.03376
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : 772.01
    Right Arm Q2 momentum                    : 1.79384
    Right Arm Q2 gauss meter                 : -0.4064
    Right Arm Q2 power supply polarity       : 1
    Right Arm D1 power supply current        : 620.461
    Right Arm D1 momentum                    : 1.794
    Right Arm D1 NMR                         : 0.665732
    Right Arm Q3 power supply current        : 714.028
    Right Arm Q3 momentum                    : 1.79445
    Right Arm Q3 gauss meter                 : -0.3203
    Right Arm Q3 power supply polarity       : 0
    Left Arm Q1 power supply current          : 1349.6
    Left Arm Q1 momentum                      : 1.79389
    Left Arm Q1 gauss meter                   : -0.1141
    Left Arm Q1 power supply polarity         : 0
    Left Arm Q2 power supply current          : 772.632
    Left Arm Q2 momentum                      : 1.79432
    Left Arm Q2 gauss meter                   : 0.4078
    Left Arm Q2 power supply polarity         : 1
    Left Arm D1 power supply current          : 605.58
    Left Arm D1 momentum                      : 1.79401
    Left Arm D1 NMR                           : 0.663892
    Left Arm Q3 power supply current          : 714.142
    Left Arm Q3 momentum                      : 1.79379
    Left Arm Q3 gauss meter                   : -0.3561
    Left Arm Q3 power supply polarity         : 1
    Average current of the two cavities     : 18.8332
    Current on Unser monitor                : 29.211
    Current on Upstream bcm                 : 18.7249
    Current on Downstream bcm               : 18.9416
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 18.9279
    MBSY1c Hall A Beam energy               : 2564.25
    MBSY1c magnet current (amp)             : 106.728
    MBSY1c Bdl                              : 639912
    MBSY3c Hall C Beam energy               : 3406.76
    Tiefenbach Hall A energy                : 2560.55
    Tiefenbach Hall C energy                : 3397.79
    Delta(E)/E width (MV_AI_DXWID)          : 0
    IPM1C12.XPOS                            : -0.0053397
    IPM1H04A.XPOS                           : 0.0455143
    IPM1H04A.YPOS                           : -0.169722
    IPM1H04B.XPOS                           : -0.043124
    IPM1H04B.YPOS                           : 0.0102353
    Right Arm Arm Collimator                 : 0.614941
    Left Arm Arm Collimator                   : 0.617041
     HacR_HPM_LVDT:VALr                     : -816
     HacR_VPM_LVDT:VALr                     : 298
     HacR_HPE1313A:0_Ch58                   : -0.543457
     HacR_HPE1313A:0_Ch55                   : 22.7539
     HacR_HPE1313A:0_Ch54                   : -0.77832
     HacR_alignROLL                         : -0.297072
     HacR_alignPITCH                        : -0.0121719
     HacR_alignHPT                          : -1.94832
     HacL_HPM_LVDT:VALr                     : -7166
     HacL_VPM_LVDT:VALr                     : 785
     HacL_HPE1313A:0_Ch58                   : -0.158203
     HacL_HPE1313A:0_Ch55                   : 23.4375
     HacL_HPE1313A:0_Ch54                   : -0.20459
     HacL_alignROLL                         : 0.15238
     HacL_alignPITCH                        : -0.103193
     HacL_alignHPT                          : 4.20082
    haBDSPOS                                 : 4.643e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 69
    haL3_Fan_frequency_R                     : 32
    haH2_P_Fill_Target_R                     : 22.02
    haH2_P_Exhaust_R                         : 22.17
    haH2_P_Fill_Bottle_R                     : 22.33
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : 30.05
    haD2_P_Exhaust_R                         : 18.1
    haD2_P_Fill_Bottle_R                     : 35.66
    haD2_DP_Fill_Exhaust_R                   : 0.0767
    haSC200_6_Sensor_1_R                     : 242.33
    haSC200_6_Sensor_2_R                     : 42.48
    haSC200_6_Sensor_3_R                     : 2.97
    haSC200_6_Sensor_4_R                     : 40.28
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 94.98
    haITC502_1_Sensor_3_R                    : 94.98
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 18.99
    haITC502_2_Sensor_3_R                    : 19.08
    haITC502_4_Sensor_1_R                    : 141.5
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 21.9
    haITC502_5_Sensor_1_R                    : 0
    haITC502_5_Sensor_2_R                    : 0
    haITC502_5_Sensor_3_R                    : 0
    haITC502_6_Sensor_1_R                    : 0
    haITC502_6_Sensor_2_R                    : 0
    haITC502_6_Sensor_3_R                    : 0
    Right Arm Arm Collimator                 : 0.614941
    Left Arm Arm Collimator                   : 0.617041
    Wien angle                               : 24.1959
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 527.39
    Wien field                               : 15.34
    Laser attenuation Hall A                 : 167
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : OFF