User name adev
Log entry time 17:26:20 on February 22, 2001
Entry number 56774
keyword=Start_Run_2127_RunType=Harp,Tar=BeO,Rad=out,comment=,mode=coincidence,Lmom=1.740,Rmom=1.438,Ene=2.558,Angle_R=43.164,Angle_L=34.413
Beginning-of-run EPICS data for Run Number 2127 at Thu Feb 22 17:26:10 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=2,ps2=4000,ps3=2,ps4=4000,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 1081.36
Right Arm Q1 momentum : 1.4381
Right Arm Q1 gauss meter : -0.026954
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 618.879
Right Arm Q2 momentum : 1.43802
Right Arm Q2 gauss meter : 0.3253
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 494.277
Right Arm D1 momentum : 1.438
Right Arm D1 NMR : 0.533625
Right Arm Q3 power supply current : 571.955
Right Arm Q3 momentum : 1.4374
Right Arm Q3 gauss meter : 0.2565
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1308.96
Left Arm Q1 momentum : 1.73988
Left Arm Q1 gauss meter : 0.11134
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 749.252
Left Arm Q2 momentum : 1.74002
Left Arm Q2 gauss meter : -0.395
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 586.241
Left Arm D1 momentum : 1.74002
Left Arm D1 NMR : 0.643924
Left Arm Q3 power supply current : 692.801
Left Arm Q3 momentum : 1.74019
Left Arm Q3 gauss meter : 0.3458
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 2.61788
Current on Unser monitor : 13.9033
Current on Upstream bcm : 2.69473
Current on Downstream bcm : 2.72518
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 60.579
Beam energy : 2564.25
MBSY1c magnet current (amp) : 106.728
Radiator 5V Linear Supply : 5.02564
Radiator Encoder : 0.163614
haBDSPOS : 190449
haL1_Fan_frequency_R : 67
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.46
haSC200_6_Sensor_2_R : 220
haSC200_6_Sensor_3_R : 36.64
haSC200_6_Sensor_4_R : 40.28
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.79
haITC502_1_Sensor_3_R : 5.88
haITC502_4_Sensor_1_R : 6
haITC502_4_Sensor_2_R : 164
haITC502_4_Sensor_3_R : 130.8
haITC502_5_Sensor_1_R : 5.81
haITC502_5_Sensor_2_R : 5.8
haITC502_5_Sensor_3_R : 273.9
haITC502_6_Sensor_1_R : 6.71
haITC502_6_Sensor_2_R : 6.15
haITC502_6_Sensor_3_R : 28.55
Right Arm Arm Collimator : 0.614941
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -4731
HacR_VPM_LVDT:VALr : 628
HacR_HPE1313A:0_Ch58 : -0.533203
HacR_HPE1313A:0_Ch55 : 22.8027
HacR_HPE1313A:0_Ch54 : -0.906738
HacR_alignROLL : -0.426672
HacR_alignPITCH : -0.0221142
HacR_alignHPT : 2.50523
HacL_HPM_LVDT:VALr : -8037
HacL_VPM_LVDT:VALr : 737
HacL_HPE1313A:0_Ch58 : -0.169922
HacL_HPE1313A:0_Ch55 : 23.584
HacL_HPE1313A:0_Ch54 : -0.217773
HacL_alignROLL : 0.14067
HacL_alignPITCH : -0.0920623
HacL_alignHPT : 5.19124
Right Arm Angle Floor Angle : 42.5
Right Arm Angle Vernier : 84
Right Arm Scattering Angle : 43.1642
Left Arm Angle Floor Angle : 34.5
Left Arm Angle Vernier : 22.3
Left Arm Scattering Angle : 34.4144
Wien angle : 24.1959
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 527.39
Wien field : 15.34
Laser attenuation Hall A : 178
Laser power Hall A : 57
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88