    User name adev

    Log entry time 04:47:16 on February 23, 2001

    Entry number 56824

    keyword=End_of_Run_2148
    ****************************
     Run Number: 2148
    End of Run Comment:
    RunType=pion_prod,Tar=dum-10cm,Rad=6,comment=coin7,mode=coincidence,Lmom=0.913,Rmom=-2.108,Ene=2.558,Angle_R=55.636,Angle_L=20.973
    
    Time of run = 6.7494955 min
    Av. current (on 3x) = 20.977864 uA
    Av. current (on 1x) = 20.941812 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|    8.4808  |    8.4954  |    8.5038
    up-down    (mC)|   -0.0423  |   -0.0341  |   -0.0211
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 5712.6122 Hz  |    272316.2 /mC  |    5.713 Hz  |   2313435  |  1000   |    272785.0 /mC
        2      | 36173.262 Hz  |   1724353.9 /mC  |    3.014 Hz  |  14649076  | 12000   |   1727322.4 /mC
        3      | 8511.9745 Hz  |    405759.8 /mC  |    8.512 Hz  |   3447092  |  1000   |    406458.3 /mC
        4      | 30808.648 Hz  |   1468626.6 /mC  |    3.081 Hz  |  12476570  | 10000   |   1471154.8 /mC
        5      | 26.863736 Hz  |      1280.6 /mC  |   26.864 Hz  |     10879  |     1   |      1282.8 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 6.477027 Hz  |       308.8 /mC  |    6.477 Hz  | 2623.0  |     1   |       309.3 /mC
        8    | 1024.0 Hz  |     48813.4 /mC  |    0.016 Hz  |    414689  | 65535   |     48897.4 /mC
        output                       321.901 Hz
    Av. deadtime from accepted triggers = -5.8278
    Av. deadtime from gated scalers = 0.1369
    Accepted triggers  = 130360.00000
    Rate of Left Arm Pulser for electronic DT  = 20.386709
    Rate of Right Arm Pulser for electronic DT  = 10.190885
    Rate of Left Arm Pulser&trig for electronic DT  = 10.188416
    Rate of Right Arm Pulser&trig for electronic DT  = 10.190885
    Left Arm Electronic DT  = 0.50024225
    Right Arm Electronic DT  = 0.0
    Rate of Left Strobe  = 62082.788
    Rate of Right Arm Strobe  = 41396.425
        Signal     |    Charge   (C)   
       upstream    |    0.0084596     
       upstream 3x |    0.0084784     
       upstream 10x|    0.0084932     
      downstream   |    0.0085019   
     downstream 3x |    0.0085125   
     downstream 10x|    0.0085143    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 2148 at Fri Feb 23 04:46:57 EST 2001
    Right Arm D1 momentum                    : 2.108
    Right Arm arm angle                      : 20.9726
    Left Arm D1 momentum                      : 0.913005
    Left Arm arm angle                        : 55.6355
    Tiefenbach Hall A energy                : 2560.56
    Right Arm arm mispointing (HPT)          : -1.88659
    Left Arm arm mispointing (HPT)            : 5.08459
    Right Arm Q1 power supply current        : 1585.11
    Right Arm Q1 momentum                    : 2.108
    Right Arm Q1 gauss meter                 : -0.03941
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 907.291
    Right Arm Q2 momentum                    : 2.10818
    Right Arm Q2 gauss meter                 : 0.4766
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 735.046
    Right Arm D1 momentum                    : 2.108
    Right Arm D1 NMR                         : 0.782254
    Right Arm Q3 power supply current        : 838.763
    Right Arm Q3 momentum                    : 2.10793
    Right Arm Q3 gauss meter                 : 0.3762
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 686.63
    Left Arm Q1 momentum                      : 0.912669
    Left Arm Q1 gauss meter                   : 0.05881
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 393.011
    Left Arm Q2 momentum                      : 0.912706
    Left Arm Q2 gauss meter                   : -0.2076
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 304.463
    Left Arm D1 momentum                      : 0.913005
    Left Arm D1 NMR                           : 0.338044
    Left Arm Q3 power supply current          : 363.501
    Left Arm Q3 momentum                      : 0.913046
    Left Arm Q3 gauss meter                   : 0.1823
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 46.1954
    Current on Unser monitor                : 56.278
    Current on Upstream bcm                 : 46.1544
    Current on Downstream bcm               : 46.2365
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 98.8466
    MBSY1c Hall A Beam energy               : 2564.25
    MBSY1c magnet current (amp)             : 106.728
    MBSY1c Bdl                              : 639912
    MBSY3c Hall C Beam energy               : 3406.76
    Tiefenbach Hall A energy                : 2560.56
    Tiefenbach Hall C energy                : 3398.78
    Delta(E)/E width (MV_AI_DXWID)          : 0
    IPM1C12.XPOS                            : 0.00174803
    IPM1H04A.XPOS                           : -0.180367
    IPM1H04A.YPOS                           : -0.253294
    IPM1H04B.XPOS                           : 0.0133367
    IPM1H04B.YPOS                           : 0.00844621
    Right Arm Arm Collimator                 : 0.61499
    Left Arm Arm Collimator                   : 0.617041
     HacR_HPM_LVDT:VALr                     : -809
     HacR_VPM_LVDT:VALr                     : 286
     HacR_HPE1313A:0_Ch58                   : -0.52832
     HacR_HPE1313A:0_Ch55                   : 22.7539
     HacR_HPE1313A:0_Ch54                   : -0.814453
     HacR_alignROLL                         : -0.332451
     HacR_alignPITCH                        : -0.02667
     HacR_alignHPT                          : -1.88855
     HacL_HPM_LVDT:VALr                     : -7899
     HacL_VPM_LVDT:VALr                     : -467
     HacL_HPE1313A:0_Ch58                   : -0.299316
     HacL_HPE1313A:0_Ch55                   : 23.6328
     HacL_HPE1313A:0_Ch54                   : -0.356934
     HacL_alignROLL                         : 0.0142608
     HacL_alignPITCH                        : 0.0232766
     HacL_alignHPT                          : 5.08613
    haBDSPOS                                 : 2.1154e+06
    haL1_Fan_frequency_R                     : 68
    haL2_Fan_frequency_R                     : 0
    haL3_Fan_frequency_R                     : 0
    haH2_P_Fill_Target_R                     : 22.28
    haH2_P_Exhaust_R                         : 22.82
    haH2_P_Fill_Bottle_R                     : 22.66
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : 29.8
    haD2_P_Exhaust_R                         : 22.76
    haD2_P_Fill_Bottle_R                     : 45.43
    haD2_DP_Fill_Exhaust_R                   : 0.0759
    haSC200_6_Sensor_1_R                     : 242.36
    haSC200_6_Sensor_2_R                     : 220.5
    haSC200_6_Sensor_3_R                     : 36.71
    haSC200_6_Sensor_4_R                     : 40.24
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 5.81
    haITC502_1_Sensor_2_R                    : 5.8
    haITC502_1_Sensor_3_R                    : 5.88
    haITC502_2_Sensor_1_R                    : 94.98
    haITC502_2_Sensor_2_R                    : 94.98
    haITC502_2_Sensor_3_R                    : 94.98
    haITC502_4_Sensor_1_R                    : 6
    haITC502_4_Sensor_2_R                    : 112.6
    haITC502_4_Sensor_3_R                    : 123.9
    haITC502_5_Sensor_1_R                    : 5.84
    haITC502_5_Sensor_2_R                    : 5.81
    haITC502_5_Sensor_3_R                    : 270.9
    haITC502_6_Sensor_1_R                    : 31.57
    haITC502_6_Sensor_2_R                    : 5.9
    haITC502_6_Sensor_3_R                    : 28.3
    Right Arm Arm Collimator                 : 0.614893
    Left Arm Arm Collimator                   : 0.617041
    Wien angle                               : 24.1959
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 527.39
    Wien field                               : 15.34
    Laser attenuation Hall A                 : 358
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : ON