User name adev
Log entry time 22:33:08 on February 23, 2001
Entry number 56884
keyword=End_of_Run_2167
****************************
Run Number: 2167
End of Run Comment:
RunType=pion_prod,Tar=4He-10cm,Rad=out,comment=coin15,mode=coincidence,Lmom=2.638,Rmom=-2.291,Ene=4.244,Angle_R=35.163,Angle_L=29.973
Time of run = 30.123665 min
Av. current (on 3x) = 42.103221 uA
Av. current (on 1x) = 42.021281 uA
| on 1x | on 3x | on 10x
Av. charge (mC)| 75.9501 | 76.0982 | 76.1524
up-down (mC)| -0.5157 | -0.2533 | -0.1896
Trigger | Rate(Hz) | Scaler/charge(3x)|Scaler/time/ps| Scaler | Prescale| Scaler/charge(1x)
1 | 255.93721 Hz | 6078.8 /mC | 63.984 Hz | 462586 | 4 | 6090.7 /mC
2 | 26721.484 Hz | 634666.0 /mC | 6.680 Hz | 48296942 | 4000 | 635903.6 /mC
3 | 862.04816 Hz | 20474.6 /mC | 57.470 Hz | 1558083 | 15 | 20514.6 /mC
4 | 28836.434 Hz | 684898.5 /mC | 7.209 Hz | 52119545 | 4000 | 686234.1 /mC
5 | 15.196247 Hz | 360.9 /mC | 15.196 Hz | 27466 | 1 | 361.6 /mC
Trigger 5 corrected for pulser:
5 (phys) | -5.172014 Hz | -122.8 /mC | -5.172 Hz | -9348.0003 | 1 | -123.1 /mC
8 | 1024.0 Hz | 24321.2 /mC | 0.016 Hz | 1850798 | 65535 | 24368.6 /mC
output 515.044 Hz
Av. deadtime from accepted triggers = -2.5339
Av. deadtime from gated scalers = 0.1156
Accepted triggers = 930901.00000
Rate of Left Arm Pulser for electronic DT = 20.368261
Rate of Right Arm Pulser for electronic DT = 10.171958
Rate of Left Arm Pulser&trig for electronic DT = 10.177491
Rate of Right Arm Pulser&trig for electronic DT = 10.171958
Left Arm Electronic DT = 0.50032596
Right Arm Electronic DT = 0.0
Rate of Left Strobe = 45425.833
Rate of Right Arm Strobe = 26179.141
Signal | Charge (C)
upstream | 0.0756922
upstream 3x | 0.0759715
upstream 10x| 0.0760576
downstream | 0.0762079
downstream 3x | 0.0762248
downstream 10x| 0.0762472
****************************
End-of-run EPICS data for Run Number 2167 at Fri Feb 23 22:32:55 EST 2001
Right Arm D1 momentum : 2.291
Right Arm arm angle : 35.1621
Left Arm D1 momentum : 2.638
Left Arm arm angle : 29.9727
Tiefenbach Hall A energy : 4235.02
Right Arm arm mispointing (HPT) : 2.59335
Left Arm arm mispointing (HPT) : 5.68353
Right Arm Q1 power supply current : 1722.81
Right Arm Q1 momentum : 2.29116
Right Arm Q1 gauss meter : -0.04283
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 985.935
Right Arm Q2 momentum : 2.29092
Right Arm Q2 gauss meter : 0.5179
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 803.171
Right Arm D1 momentum : 2.291
Right Arm D1 NMR : 0.850163
Right Arm Q3 power supply current : 911.357
Right Arm Q3 momentum : 2.29037
Right Arm Q3 gauss meter : 0.4087
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1984.68
Left Arm Q1 momentum : 2.63803
Left Arm Q1 gauss meter : 0.16836
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1135.9
Left Arm Q2 momentum : 2.63794
Left Arm Q2 gauss meter : -0.5983
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 913.202
Left Arm D1 momentum : 2.638
Left Arm D1 NMR : 0.976517
Left Arm Q3 power supply current : 1050.21
Left Arm Q3 momentum : 2.63792
Left Arm Q3 gauss meter : 0.5242
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 45.1813
Current on Unser monitor : 57.7277
Current on Upstream bcm : 45.1387
Current on Downstream bcm : 45.224
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 104.101
MBSY1c Hall A Beam energy : 4243.78
MBSY1c magnet current (amp) : 176.909
MBSY1c Bdl : 1.05904e+06
MBSY3c Hall C Beam energy : 3406.76
Tiefenbach Hall A energy : 4235.02
Tiefenbach Hall C energy : 3398.78
Delta(E)/E width (MV_AI_DXWID) : 0.467339
IPM1C12.XPOS : 0.0169301
IPM1H04A.XPOS : -0.245839
IPM1H04A.YPOS : 0.367997
IPM1H04B.XPOS : 0.0342637
IPM1H04B.YPOS : 0.000238583
Right Arm Arm Collimator : 0.614941
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -4856
HacR_VPM_LVDT:VALr : 460
HacR_HPE1313A:0_Ch58 : -0.53418
HacR_HPE1313A:0_Ch55 : 22.8516
HacR_HPE1313A:0_Ch54 : -0.820801
HacR_alignROLL : -0.340223
HacR_alignPITCH : -0.020967
HacR_alignHPT : 2.5947
HacL_HPM_LVDT:VALr : -8462
HacL_VPM_LVDT:VALr : 901
HacL_HPE1313A:0_Ch58 : -0.147949
HacL_HPE1313A:0_Ch55 : 23.5352
HacL_HPE1313A:0_Ch54 : -0.249512
HacL_alignROLL : 0.111001
HacL_alignPITCH : -0.112073
HacL_alignHPT : 5.68147
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 63.5
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haH2_P_Fill_Target_R : 21.73
haH2_P_Exhaust_R : 22.35
haH2_P_Fill_Bottle_R : 22.07
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : 30.25
haD2_P_Exhaust_R : 22.56
haD2_P_Fill_Bottle_R : 45.16
haD2_DP_Fill_Exhaust_R : 0.076
haSC200_6_Sensor_1_R : 242.26
haSC200_6_Sensor_2_R : 216.12
haSC200_6_Sensor_3_R : 36.72
haSC200_6_Sensor_4_R : 40.39
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.8
haITC502_1_Sensor_3_R : 5.98
haITC502_2_Sensor_1_R : 94.98
haITC502_2_Sensor_2_R : 93.61
haITC502_2_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 6.1
haITC502_4_Sensor_2_R : 106.9
haITC502_4_Sensor_3_R : 127.1
haITC502_5_Sensor_1_R : 5.89
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 267.4
haITC502_6_Sensor_1_R : 24.09
haITC502_6_Sensor_2_R : 5.99
haITC502_6_Sensor_3_R : 28.43
Right Arm Arm Collimator : 0.614941
Left Arm Arm Collimator : 0.616992
Wien angle : 24.1959
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 527.39
Wien field : 15.34
Laser attenuation Hall A : 238
Laser power Hall A : 57
Half-wave plate (off=out) : ON