User name adev
Log entry time 22:58:02 on February 24, 2001
Entry number 56934
keyword=End_of_Run_2185
****************************
Run Number: 2185
End of Run Comment:
RunType=Cosmic,Tar=absence,Rad=out,comment=coin14_ped,mode=coincidence,Lmom=1.949,Rmom=-2.929,Ene=4.244,Angle_R=25.06,Angle_L=39.47
Time of run = 96.432943 min
Av. current (on 3x) = 0.030573922 uA
Av. current (on 1x) = 0.04224006 uA
| on 1x | on 3x | on 10x
Av. charge (mC)| 0.2444 | 0.1769 | 0.2563
up-down (mC)| 0.3917 | -0.0799 | 0.0604
Trigger | Rate(Hz) | Scaler/charge(3x)|Scaler/time/ps| Scaler | Prescale| Scaler/charge(1x)
1 | 17.129865 Hz | 560277.0 /mC | 0.571 Hz | 99113 | 30 | 405536.0 /mC
2 | 1434.4998 Hz | 46919062.0 /mC | 0.143 Hz | 8299982 | 10000 | 33960646.0 /mC
3 | 17.828624 Hz | 583131.7 /mC | 0.198 Hz | 103156 | 90 | 422078.6 /mC
4 | 850.41322 Hz | 27814986.0 /mC | 0.085 Hz | 4920471 | 10000 | 20132860.0 /mC
5 | 10.159218 Hz | 332283.8 /mC | 10.159 Hz | 58781 | 1 | 240511.5 /mC
Trigger 5 corrected for pulser:
5 (phys) | -10.158527 Hz | -332261.2 /mC | -10.159 Hz | -58776.997 | 1 | -240495.1 /mC
8 | 1024.0 Hz | 33492595.0 /mC | 0.016 Hz | 5924840 | 65535 | 24242390.0 /mC
output 10.718 Hz
Av. deadtime from accepted triggers = 0.0002
Av. deadtime from gated scalers = -0.0342
Accepted triggers = 62014.00000
Rate of Left Arm Pulser for electronic DT = 20.317745
Rate of Right Arm Pulser for electronic DT = 0.0
Rate of Left Arm Pulser&trig for electronic DT = 10.1587
Rate of Right Arm Pulser&trig for electronic DT = 0.0
Left Arm Electronic DT = 0.50000851
Right Arm Electronic DT = -1
Rate of Left Strobe = 1644.4619
Rate of Right Arm Strobe = 1557.9526
Signal | Charge (C)
upstream | 0.0004402
upstream 3x | 0.0001369
upstream 10x| 0.0002865
downstream | 0.0000485
downstream 3x | 0.0002168
downstream 10x| 0.0002261
****************************
End-of-run EPICS data for Run Number 2185 at Sat Feb 24 22:57:50 EST 2001
Right Arm D1 momentum : 0
Right Arm arm angle : 25.0602
Left Arm D1 momentum : 0
Left Arm arm angle : 39.4693
Tiefenbach Hall A energy : 4235.15
Right Arm arm mispointing (HPT) : -1.93423
Left Arm arm mispointing (HPT) : 5.75781
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0
Right Arm Q1 gauss meter : 4.62e-05
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 0.322337
Right Arm Q2 momentum : 0.00074898
Right Arm Q2 gauss meter : -0.0002563
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 1.64459
Right Arm D1 momentum : 0
Right Arm D1 NMR : 0.366716
Right Arm Q3 power supply current : 0.0997411
Right Arm Q3 momentum : 0.000250663
Right Arm Q3 gauss meter : -0.0001811
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 0
Left Arm Q1 momentum : 0
Left Arm Q1 gauss meter : 0.0003816
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 0.0753881
Left Arm Q2 momentum : 0.000175077
Left Arm Q2 gauss meter : 0.0001137
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 0.134013
Left Arm D1 momentum : 0
Left Arm D1 NMR : 0.490565
Left Arm Q3 power supply current : 1.81866
Left Arm Q3 momentum : 0.00456812
Left Arm Q3 gauss meter : 0.0008307
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 0
Current on Unser monitor : 5.41484
Current on Upstream bcm : 0
Current on Downstream bcm : 0
Upstream Cavity Coefficient : 0
Downstream Cavity Coefficient : 0
Current on IBC0L02 (source) : 5.22557e-304
MBSY1c Hall A Beam energy : 4243.78
MBSY1c magnet current (amp) : 176.909
MBSY1c Bdl : 1.05904e+06
MBSY3c Hall C Beam energy : 3406.76
Tiefenbach Hall A energy : 4235.15
Tiefenbach Hall C energy : 3397.71
Delta(E)/E width (MV_AI_DXWID) : 2.49619
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Right Arm Arm Collimator : 0.614746
Left Arm Arm Collimator : 0.616504
HacR_HPM_LVDT:VALr : -800
HacR_VPM_LVDT:VALr : 219
HacR_HPE1313A:0_Ch58 : -0.532715
HacR_HPE1313A:0_Ch55 : 22.5098
HacR_HPE1313A:0_Ch54 : -0.794434
HacR_alignROLL : -0.313082
HacR_alignPITCH : -0.0217815
HacR_alignHPT : -1.93171
HacL_HPM_LVDT:VALr : -8539
HacL_VPM_LVDT:VALr : 185
HacL_HPE1313A:0_Ch58 : -0.193359
HacL_HPE1313A:0_Ch55 : 23.4863
HacL_HPE1313A:0_Ch54 : -0.257812
HacL_alignROLL : 0.103863
HacL_alignPITCH : -0.0722681
HacL_alignHPT : 5.75823
haBDSPOS : 0
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haH2_P_Fill_Target_R : 28.37
haH2_P_Exhaust_R : 28.97
haH2_P_Fill_Bottle_R : 28.71
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : 30.35
haD2_P_Exhaust_R : 26.44
haD2_P_Fill_Bottle_R : 52.96
haD2_DP_Fill_Exhaust_R : 0.0761
haSC200_6_Sensor_1_R : 241.69
haSC200_6_Sensor_2_R : 12.66
haSC200_6_Sensor_3_R : 36.64
haSC200_6_Sensor_4_R : 40.13
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_2_Sensor_1_R : 94.98
haITC502_2_Sensor_2_R : 94.98
haITC502_2_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 160.3
haITC502_4_Sensor_2_R : 184
haITC502_4_Sensor_3_R : 193.2
haITC502_5_Sensor_1_R : 99.88
haITC502_5_Sensor_2_R : 99.54
haITC502_5_Sensor_3_R : 273.6
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.99
Right Arm Arm Collimator : 0.614746
Left Arm Arm Collimator : 0.616455
Wien angle : 24.1959
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 527.39
Wien field : 15.34
Laser attenuation Hall A : 100
Laser power Hall A : 57
Half-wave plate (off=out) : ON