    User name adev

    Log entry time 22:35:44 on February 26, 2001

    Entry number 57036

    keyword=End_of_Run_2221
    ****************************
     Run Number: 2221
    End of Run Comment:
    RunType=pion_prod,Tar=dum-10cm,Rad=6,comment=coin13,mode=coincidence,Lmom=-3.489,Rmom=1.300,Ene=4.232,Angle_R=51.024,Angle_L=16.810
    
    
    Time of run = 33.040185 min
    Av. current (on 3x) = 44.854571 uA
    Av. current (on 1x) = 44.734415 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|   88.6820  |   88.9202  |   88.9801
    up-down    (mC)|   -0.4784  |   -0.0806  |   -0.0169
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 6157.3974 Hz  |    137274.7 /mC  |  256.558 Hz  |  12206493  |    24   |    137643.4 /mC
        2      | 43967.44 Hz  |    980222.1 /mC  |   73.279 Hz  |  87161542  |   600   |    982854.9 /mC
        3      | 6146.6217 Hz  |    137034.5 /mC  |   87.809 Hz  |  12185131  |    70   |    137402.5 /mC
        4      | 64101.368 Hz  |   1429093.3 /mC  |   91.573 Hz  | 127075260  |   700   |   1432931.8 /mC
        5      | 26.05161 Hz  |       580.8 /mC  |   26.052 Hz  |     51645  |     1   |       582.4 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 15.870069 Hz  |       353.8 /mC  |   15.870 Hz  | 31461.0  |     1   |       354.8 /mC
        8    | 1024.0 Hz  |     22829.3 /mC  |    0.016 Hz  |   2029989  | 65535   |     22890.7 /mC
        output                       506.432 Hz
    Av. deadtime from accepted triggers = 0.0513
    Av. deadtime from gated scalers = 0.0730
    Accepted triggers  = 1003956.00000
    Rate of Left Arm Pulser for electronic DT  = 10.181541
    Rate of Right Arm Pulser for electronic DT  = 0.0
    Rate of Left Arm Pulser&trig for electronic DT  = 10.17801
    Rate of Right Arm Pulser&trig for electronic DT  = 0.0
    Left Arm Electronic DT  = 0.00034680935
    Right Arm Electronic DT  = -1
    Rate of Left Strobe  = 105492.07
    Rate of Right Arm Strobe  = 53357.756
        Signal     |    Charge   (C)   
       upstream    |    0.0884428     
       upstream 3x |    0.0888799     
       upstream 10x|    0.0889717     
      downstream   |    0.0889212   
     downstream 3x |    0.0889605   
     downstream 10x|    0.0889886    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 2221 at Mon Feb 26 22:35:28 EST 2001
    Right Arm D1 momentum                    : 1.3
    Right Arm arm angle                      : 51.0236
    Left Arm D1 momentum                      : 3.489
    Left Arm arm angle                        : 16.8094
    Tiefenbach Hall A energy                : 4234.99
    Right Arm arm mispointing (HPT)          : 2.62757
    Left Arm arm mispointing (HPT)            : 4.27027
    Right Arm Q1 power supply current        : 977.515
    Right Arm Q1 momentum                    : 1.3
    Right Arm Q1 gauss meter                 : 0.024558
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : 559.541
    Right Arm Q2 momentum                    : 1.30015
    Right Arm Q2 gauss meter                 : -0.2948
    Right Arm Q2 power supply polarity       : 1
    Right Arm D1 power supply current        : 446.879
    Right Arm D1 momentum                    : 1.3
    Right Arm D1 NMR                         : 0.482415
    Right Arm Q3 power supply current        : 517.037
    Right Arm Q3 momentum                    : 1.29939
    Right Arm Q3 gauss meter                 : -0.2322
    Right Arm Q3 power supply polarity       : 0
    Left Arm Q1 power supply current          : 2625.14
    Left Arm Q1 momentum                      : 3.48934
    Left Arm Q1 gauss meter                   : -0.22199
    Left Arm Q1 power supply polarity         : 0
    Left Arm Q2 power supply current          : 1502.4
    Left Arm Q2 momentum                      : 3.48909
    Left Arm Q2 gauss meter                   : 0.791
    Left Arm Q2 power supply polarity         : 1
    Left Arm D1 power supply current          : 1247.39
    Left Arm D1 momentum                      : 3.489
    Left Arm D1 NMR                           : 1.29229
    Left Arm Q3 power supply current          : 1389.05
    Left Arm Q3 momentum                      : 3.48903
    Left Arm Q3 gauss meter                   : -0.693
    Left Arm Q3 power supply polarity         : 1
    Average current of the two cavities     : 48.0773
    Current on Unser monitor                : 54.58
    Current on Upstream bcm                 : 47.8328
    Current on Downstream bcm               : 47.7461
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 5.22557e-304
    MBSY1c Hall A Beam energy               : 4243.78
    MBSY1c magnet current (amp)             : 176.909
    MBSY1c Bdl                              : 1.05904e+06
    MBSY3c Hall C Beam energy               : 3406.76
    Tiefenbach Hall A energy                : 4234.99
    Tiefenbach Hall C energy                : 3398.12
    Delta(E)/E width (MV_AI_DXWID)          : 4.77844
    IPM1C12.XPOS                            : 0.00760078
    IPM1H04A.XPOS                           : -0.104397
    IPM1H04A.YPOS                           : 0.446938
    IPM1H04B.XPOS                           : 0.0288541
    IPM1H04B.YPOS                           : -0.0237455
    Right Arm Arm Collimator                 : 0.614746
    Left Arm Arm Collimator                   : 0.616455
     HacR_HPM_LVDT:VALr                     : -4901
     HacR_VPM_LVDT:VALr                     : 322
     HacR_HPE1313A:0_Ch58                   : -0.533203
     HacR_HPE1313A:0_Ch55                   : 22.6074
     HacR_HPE1313A:0_Ch54                   : -0.835449
     HacR_alignROLL                         : -0.355302
     HacR_alignPITCH                        : -0.02243
     HacR_alignHPT                          : 2.62896
     HacL_HPM_LVDT:VALr                     : -7322
     HacL_VPM_LVDT:VALr                     : 2417
     HacL_HPE1313A:0_Ch58                   : -0.148438
     HacL_HPE1313A:0_Ch55                   : 23.3398
     HacL_HPE1313A:0_Ch54                   : 0.0332031
     HacL_alignROLL                         : 0.372763
     HacL_alignPITCH                        : -0.131815
     HacL_alignHPT                          : 4.26934
    haBDSPOS                                 : 2.1154e+06
    haL1_Fan_frequency_R                     : 67.5
    haL2_Fan_frequency_R                     : 0
    haL3_Fan_frequency_R                     : 0
    haH2_P_Fill_Target_R                     : 20.41
    haH2_P_Exhaust_R                         : 21.11
    haH2_P_Fill_Bottle_R                     : 20.92
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : 30.08
    haD2_P_Exhaust_R                         : 21.22
    haD2_P_Fill_Bottle_R                     : 42.59
    haD2_DP_Fill_Exhaust_R                   : 0.0767
    haSC200_6_Sensor_1_R                     : 241.91
    haSC200_6_Sensor_2_R                     : 216.2
    haSC200_6_Sensor_3_R                     : 37.06
    haSC200_6_Sensor_4_R                     : 40.68
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 5.8
    haITC502_1_Sensor_2_R                    : 5.8
    haITC502_1_Sensor_3_R                    : 5.87
    haITC502_2_Sensor_1_R                    : 88.08
    haITC502_2_Sensor_2_R                    : 87.03
    haITC502_2_Sensor_3_R                    : 88.19
    haITC502_4_Sensor_1_R                    : 6
    haITC502_4_Sensor_2_R                    : 101.1
    haITC502_4_Sensor_3_R                    : 122.2
    haITC502_5_Sensor_1_R                    : 5.87
    haITC502_5_Sensor_2_R                    : 5.8
    haITC502_5_Sensor_3_R                    : 271.7
    haITC502_6_Sensor_1_R                    : 18.88
    haITC502_6_Sensor_2_R                    : 6.02
    haITC502_6_Sensor_3_R                    : 28.55
    Right Arm Arm Collimator                 : 0.614746
    Left Arm Arm Collimator                   : 0.616504
    Wien angle                               : 24.1959
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 527.39
    Wien field                               : 15.34
    Laser attenuation Hall A                 : 278
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : ON