    User name adev

    Log entry time 06:08:36 on February 28, 2001

    Entry number 57155

    keyword=End_of_Run_2267
    ****************************
     Run Number: 2267
    End of Run Comment:
    RunType=pion_prod,Tar=dum-15cm,Rad=out,comment=coin13R,mode=coincidence,Lmom=-3.489,Rmom=1.300,Ene=4.232,Angle_R=51.024,Angle_L=16.810
    
    Time of run = 16.199137 min
    Av. current (on 3x) = 28.410361 uA
    Av. current (on 1x) = 28.325788 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|   27.5312  |   27.6134  |   27.6578
    up-down    (mC)|   -0.1335  |   -0.0438  |   -0.0059
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 380.32581 Hz  |     13386.9 /mC  |    1.902 Hz  |    369657  |   200   |     13426.8 /mC
        2      | 8134.1173 Hz  |    286308.1 /mC  |    2.711 Hz  |   7905941  |  3000   |    287163.0 /mC
        3      | 3848.9519 Hz  |    135477.0 /mC  |    8.553 Hz  |   3740982  |   450   |    135881.5 /mC
        4      | 11935.29 Hz  |    420103.4 /mC  |    1.989 Hz  |  11600484  |  6000   |    421357.7 /mC
        5      | 12.534618 Hz  |       441.2 /mC  |   12.535 Hz  |     12183  |     1   |       442.5 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 2.356092 Hz  |        82.9 /mC  |    2.356 Hz  | 2289.9996  |     1   |        83.2 /mC
        8    | 1024.0 Hz  |     36043.2 /mC  |    0.016 Hz  |    995275  | 65535   |     36150.8 /mC
        output                        27.535 Hz
    Av. deadtime from accepted triggers = 0.0029
    Av. deadtime from gated scalers = 0.0038
    Accepted triggers  =  26763.00000
    Rate of Left Arm Pulser for electronic DT  = 10.178526
    Rate of Right Arm Pulser for electronic DT  = 0.0
    Rate of Left Arm Pulser&trig for electronic DT  = 10.177497
    Rate of Right Arm Pulser&trig for electronic DT  = 0.0
    Left Arm Electronic DT  = 0.00010108157
    Right Arm Electronic DT  = -1
    Rate of Left Strobe  = 23638.32
    Rate of Right Arm Strobe  = 8714.8756
        Signal     |    Charge   (C)   
       upstream    |    0.0274645     
       upstream 3x |    0.0275915     
       upstream 10x|    0.0276549     
      downstream   |    0.0275980   
     downstream 3x |    0.0276353   
     downstream 10x|    0.0276608    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 2267 at Wed Feb 28 06:08:16 EST 2001
    Right Arm D1 momentum                    : 1.3
    Right Arm arm angle                      : 51.0237
    Left Arm D1 momentum                      : 3.489
    Left Arm arm angle                        : 16.8089
    Tiefenbach Hall A energy                : 4235.02
    Right Arm arm mispointing (HPT)          : 2.60339
    Left Arm arm mispointing (HPT)            : 4.33385
    Right Arm Q1 power supply current        : 977.585
    Right Arm Q1 momentum                    : 1.30009
    Right Arm Q1 gauss meter                 : 0.024553
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : 559.582
    Right Arm Q2 momentum                    : 1.30024
    Right Arm Q2 gauss meter                 : -0.2947
    Right Arm Q2 power supply polarity       : 1
    Right Arm D1 power supply current        : 446.872
    Right Arm D1 momentum                    : 1.3
    Right Arm D1 NMR                         : 0.482414
    Right Arm Q3 power supply current        : 517.11
    Right Arm Q3 momentum                    : 1.29957
    Right Arm Q3 gauss meter                 : -0.2322
    Right Arm Q3 power supply polarity       : 0
    Left Arm Q1 power supply current          : 2625.1
    Left Arm Q1 momentum                      : 3.48929
    Left Arm Q1 gauss meter                   : -0.22199
    Left Arm Q1 power supply polarity         : 0
    Left Arm Q2 power supply current          : 1502.52
    Left Arm Q2 momentum                      : 3.48937
    Left Arm Q2 gauss meter                   : 0.791
    Left Arm Q2 power supply polarity         : 1
    Left Arm D1 power supply current          : 1247.39
    Left Arm D1 momentum                      : 3.489
    Left Arm D1 NMR                           : 1.29229
    Left Arm Q3 power supply current          : 1389.08
    Left Arm Q3 momentum                      : 3.48911
    Left Arm Q3 gauss meter                   : -0.693
    Left Arm Q3 power supply polarity         : 1
    Average current of the two cavities     : 28.1586
    Current on Unser monitor                : 34.8574
    Current on Upstream bcm                 : 28.3741
    Current on Downstream bcm               : 27.9432
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 81.683
    MBSY1c Hall A Beam energy               : 4243.78
    MBSY1c magnet current (amp)             : 176.909
    MBSY1c Bdl                              : 1.05904e+06
    MBSY3c Hall C Beam energy               : 3406.76
    Tiefenbach Hall A energy                : 4235
    Tiefenbach Hall C energy                : 3398.09
    Delta(E)/E width (MV_AI_DXWID)          : 4.80618
    IPM1C12.XPOS                            : -0.00217986
    IPM1H04A.XPOS                           : -0.0934882
    IPM1H04A.YPOS                           : 0.419333
    IPM1H04B.XPOS                           : 0.0658752
    IPM1H04B.YPOS                           : -0.0452725
    Right Arm Arm Collimator                 : 0.614795
    Left Arm Arm Collimator                   : 0.616504
     HacR_HPM_LVDT:VALr                     : -4876
     HacR_VPM_LVDT:VALr                     : 353
     HacR_HPE1313A:0_Ch58                   : -0.527832
     HacR_HPE1313A:0_Ch55                   : 22.7051
     HacR_HPE1313A:0_Ch54                   : -0.839844
     HacR_alignROLL                         : -0.359681
     HacR_alignPITCH                        : -0.0268522
     HacR_alignHPT                          : 2.6021
     HacL_HPM_LVDT:VALr                     : -7378
     HacL_VPM_LVDT:VALr                     : 2441
     HacL_HPE1313A:0_Ch58                   : -0.143555
     HacL_HPE1313A:0_Ch55                   : 23.4863
     HacL_HPE1313A:0_Ch54                   : 0.0292969
     HacL_alignROLL                         : 0.368271
     HacL_alignPITCH                        : -0.137203
     HacL_alignHPT                          : 4.33385
    haBDSPOS                                 : 1.72635e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 28
    haL3_Fan_frequency_R                     : 25
    haH2_P_Fill_Target_R                     : 24.24
    haH2_P_Exhaust_R                         : 24.96
    haH2_P_Fill_Bottle_R                     : 24.73
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -880
    haD2_P_Exhaust_R                         : 20.98
    haD2_P_Fill_Bottle_R                     : 43.3
    haD2_DP_Fill_Exhaust_R                   : 0.0764
    haSC200_6_Sensor_1_R                     : 241.79
    haSC200_6_Sensor_2_R                     : 25.71
    haSC200_6_Sensor_3_R                     : 37.19
    haSC200_6_Sensor_4_R                     : 40.51
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 84.6
    haITC502_1_Sensor_2_R                    : 83.74
    haITC502_1_Sensor_3_R                    : 77.11
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 18.99
    haITC502_2_Sensor_3_R                    : 18.92
    haITC502_4_Sensor_1_R                    : 83.6
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 21.9
    haITC502_5_Sensor_1_R                    : 89.28
    haITC502_5_Sensor_2_R                    : 83.2
    haITC502_5_Sensor_3_R                    : 271
    haITC502_6_Sensor_1_R                    : 95.97
    haITC502_6_Sensor_2_R                    : 81.02
    haITC502_6_Sensor_3_R                    : 28.35
    Right Arm Arm Collimator                 : 0.614746
    Left Arm Arm Collimator                   : 0.616553
    Wien angle                               : 24.1959
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 527.39
    Wien field                               : 15.34
    Laser attenuation Hall A                 : 234
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : OFF