    User name adev

    Log entry time 15:14:11 on February 28, 2001

    Entry number 57174

    keyword=End_of_Run_2271
    ****************************
     Run Number: 2271
    End of Run Comment:
    RunType=pion_prod,Tar=LH2-15cm,Rad=6,comment=coin15,mode=coincidence,Lmom=2.638,Rmom=-2.291,Ene=4.232,Angle_R=35.194,Angle_L=29.971
    
    
    Time of run = 48.806267 min
    Av. current (on 3x) = 28.578024 uA
    Av. current (on 1x) = 28.49576 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|   83.4463  |   83.6872  |   83.8174
    up-down    (mC)|   -0.4799  |   -0.1962  |   -0.0869
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 284.53108 Hz  |      9956.3 /mC  |  142.266 Hz  |    833214  |     2   |      9985.0 /mC
        2      | 43931.503 Hz  |   1537247.8 /mC  |   19.969 Hz  | 128647960  |  2200   |   1541685.6 /mC
        3      | 501.68319 Hz  |     17554.9 /mC  |  167.228 Hz  |   1469117  |     3   |     17605.5 /mC
        4      | 48245.366 Hz  |   1688198.1 /mC  |   19.298 Hz  | 141280570  |  2500   |   1693071.7 /mC
        5      | 26.486353 Hz  |       926.8 /mC  |   26.486 Hz  |     77562  |     1   |       929.5 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 16.308357 Hz  |       570.7 /mC  |   16.308 Hz  | 47757.001  |     1   |       572.3 /mC
        8    | 1024.0 Hz  |     35831.7 /mC  |    0.016 Hz  |   2998657  | 65535   |     35935.2 /mC
        output                       341.623 Hz
    Av. deadtime from accepted triggers = 0.0328
    Av. deadtime from gated scalers = 0.0482
    Accepted triggers  = 1000401.00000
    Rate of Left Arm Pulser for electronic DT  = 10.177996
    Rate of Right Arm Pulser for electronic DT  = 0.0
    Rate of Left Arm Pulser&trig for electronic DT  = 10.177996
    Rate of Right Arm Pulser&trig for electronic DT  = 0.0
    Left Arm Electronic DT  = 0.0
    Right Arm Electronic DT  = -1
    Rate of Left Strobe  = 75796.474
    Rate of Right Arm Strobe  = 43114.757
        Signal     |    Charge   (C)   
       upstream    |    0.0832064     
       upstream 3x |    0.0835891     
       upstream 10x|    0.0837740     
      downstream   |    0.0836863   
     downstream 3x |    0.0837853   
     downstream 10x|    0.0838609    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 2271 at Wed Feb 28 15:13:56 EST 2001
    Right Arm D1 momentum                    : 2.291
    Right Arm arm angle                      : 35.1935
    Left Arm D1 momentum                      : 2.638
    Left Arm arm angle                        : 29.9712
    Tiefenbach Hall A energy                : 4234.99
    Right Arm arm mispointing (HPT)          : -1.94867
    Left Arm arm mispointing (HPT)            : 5.72778
    Right Arm Q1 power supply current        : 1722.7
    Right Arm Q1 momentum                    : 2.29102
    Right Arm Q1 gauss meter                 : -0.04284
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 986.159
    Right Arm Q2 momentum                    : 2.29144
    Right Arm Q2 gauss meter                 : 0.5179
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 803.126
    Right Arm D1 momentum                    : 2.291
    Right Arm D1 NMR                         : 0.850163
    Right Arm Q3 power supply current        : 911.52
    Right Arm Q3 momentum                    : 2.29078
    Right Arm Q3 gauss meter                 : 0.4088
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 1984.68
    Left Arm Q1 momentum                      : 2.63803
    Left Arm Q1 gauss meter                   : 0.16836
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 1135.79
    Left Arm Q2 momentum                      : 2.63768
    Left Arm Q2 gauss meter                   : -0.5981
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 912.937
    Left Arm D1 momentum                      : 2.638
    Left Arm D1 NMR                           : 0.976515
    Left Arm Q3 power supply current          : 1050.27
    Left Arm Q3 momentum                      : 2.63809
    Left Arm Q3 gauss meter                   : 0.5242
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 29.2312
    Current on Unser monitor                : 35.4343
    Current on Upstream bcm                 : 29.4006
    Current on Downstream bcm               : 29.0617
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 95.481
    MBSY1c Hall A Beam energy               : 4243.78
    MBSY1c magnet current (amp)             : 176.909
    MBSY1c Bdl                              : 1.05904e+06
    MBSY3c Hall C Beam energy               : 3406.76
    Tiefenbach Hall A energy                : 4234.99
    Tiefenbach Hall C energy                : 3398.2
    Delta(E)/E width (MV_AI_DXWID)          : 4.80215
    IPM1C12.XPOS                            : -0.0249598
    IPM1H04A.XPOS                           : -0.185503
    IPM1H04A.YPOS                           : 0.440068
    IPM1H04B.XPOS                           : -0.0100152
    IPM1H04B.YPOS                           : 0.0254885
    Right Arm Arm Collimator                 : 0.615039
    Left Arm Arm Collimator                   : 0.616943
     HacR_HPM_LVDT:VALr                     : -771
     HacR_VPM_LVDT:VALr                     : 597
     HacR_HPE1313A:0_Ch58                   : -0.526367
     HacR_HPE1313A:0_Ch55                   : 22.7539
     HacR_HPE1313A:0_Ch54                   : -0.867676
     HacR_alignROLL                         : -0.387232
     HacR_alignPITCH                        : -0.02795
     HacR_alignHPT                          : -1.94842
     HacL_HPM_LVDT:VALr                     : -8499
     HacL_VPM_LVDT:VALr                     : 1017
     HacL_HPE1313A:0_Ch58                   : -0.146973
     HacL_HPE1313A:0_Ch55                   : 23.584
     HacL_HPE1313A:0_Ch54                   : -0.259766
     HacL_alignROLL                         : 0.103121
     HacL_alignPITCH                        : -0.113457
     HacL_alignHPT                          : 5.72548
    haBDSPOS                                 : 4.643e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 50
    haL3_Fan_frequency_R                     : 24.5
    haH2_P_Fill_Target_R                     : 24.69
    haH2_P_Exhaust_R                         : 25.37
    haH2_P_Fill_Bottle_R                     : 25.18
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -999.99
    haD2_P_Exhaust_R                         : 21.45
    haD2_P_Fill_Bottle_R                     : 44.11
    haD2_DP_Fill_Exhaust_R                   : 0.0761
    haSC200_6_Sensor_1_R                     : 242.13
    haSC200_6_Sensor_2_R                     : 25.47
    haSC200_6_Sensor_3_R                     : 37.41
    haSC200_6_Sensor_4_R                     : 40.71
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 83.02
    haITC502_1_Sensor_2_R                    : 82.17
    haITC502_1_Sensor_3_R                    : 74.58
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19.11
    haITC502_4_Sensor_1_R                    : 82
    haITC502_4_Sensor_2_R                    : 19.1
    haITC502_4_Sensor_3_R                    : 21.9
    haITC502_5_Sensor_1_R                    : 87.63
    haITC502_5_Sensor_2_R                    : 81.68
    haITC502_5_Sensor_3_R                    : 267.9
    haITC502_6_Sensor_1_R                    : 93.87
    haITC502_6_Sensor_2_R                    : 79
    haITC502_6_Sensor_3_R                    : 28.21
    Right Arm Arm Collimator                 : 0.615088
    Left Arm Arm Collimator                   : 0.616895
    Wien angle                               : 24.1959
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 527.39
    Wien field                               : 15.34
    Laser attenuation Hall A                 : 233
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : OFF