User name adev
Log entry time 18:57:33 on February 28, 2001
Entry number 57189
keyword=Start_Run_2276_RunType=pion_prod,Tar=LD2-15cm,Rad=out,comment=coin15,mode=coincidence,Lmom=2.638,Rmom=-2.291,Ene=4.232,Angle_R=35.194,Angle_L=29.971
Beginning-of-run EPICS data for Run Number 2276 at Wed Feb 28 18:57:17 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=6,ps2=3000,ps3=13,ps4=3500,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 1722.67
Right Arm Q1 momentum : 2.29098
Right Arm Q1 gauss meter : -0.04284
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 985.731
Right Arm Q2 momentum : 2.29044
Right Arm Q2 gauss meter : 0.5178
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 803.11
Right Arm D1 momentum : 2.291
Right Arm D1 NMR : 0.850163
Right Arm Q3 power supply current : 911.498
Right Arm Q3 momentum : 2.29059
Right Arm Q3 gauss meter : 0.4088
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1984.68
Left Arm Q1 momentum : 2.63803
Left Arm Q1 gauss meter : 0.16838
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1135.8
Left Arm Q2 momentum : 2.63852
Left Arm Q2 gauss meter : -0.5981
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 912.938
Left Arm D1 momentum : 2.638
Left Arm D1 NMR : 0.976515
Left Arm Q3 power supply current : 1050.21
Left Arm Q3 momentum : 2.63793
Left Arm Q3 gauss meter : 0.5242
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 28.2997
Current on Unser monitor : 34.6808
Current on Upstream bcm : 28.5411
Current on Downstream bcm : 28.0583
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 90.2022
Beam energy : 4243.78
MBSY1c magnet current (amp) : 176.909
Radiator 5V Linear Supply : 5.0232
Radiator Encoder : 0.600733
haBDSPOS : 3.10127e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 25
haL3_Fan_frequency_R : 36.5
haSC200_6_Sensor_1_R : 242.1
haSC200_6_Sensor_2_R : 25.44
haSC200_6_Sensor_3_R : 37.44
haSC200_6_Sensor_4_R : 40.69
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 82.89
haITC502_1_Sensor_2_R : 82.07
haITC502_1_Sensor_3_R : 74.82
haITC502_4_Sensor_1_R : 81.8
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 22
haITC502_5_Sensor_1_R : 87.6
haITC502_5_Sensor_2_R : 81.52
haITC502_5_Sensor_3_R : 269.2
haITC502_6_Sensor_1_R : 93.78
haITC502_6_Sensor_2_R : 78.87
haITC502_6_Sensor_3_R : 28.2
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.616943
HacR_HPM_LVDT:VALr : -778
HacR_VPM_LVDT:VALr : 602
HacR_HPE1313A:0_Ch58 : -0.526367
HacR_HPE1313A:0_Ch55 : 22.8027
HacR_HPE1313A:0_Ch54 : -0.864746
HacR_alignROLL : -0.384217
HacR_alignPITCH : -0.0284657
HacR_alignHPT : -1.94231
HacL_HPM_LVDT:VALr : -8492
HacL_VPM_LVDT:VALr : 1016
HacL_HPE1313A:0_Ch58 : -0.146973
HacL_HPE1313A:0_Ch55 : 23.5352
HacL_HPE1313A:0_Ch54 : -0.256836
HacL_alignROLL : 0.105259
HacL_alignPITCH : -0.113383
HacL_alignHPT :
Right Arm Angle Floor Angle : 35
Right Arm Angle Vernier : -2.9
Right Arm Scattering Angle : 35.1934
Left Arm Angle Floor Angle : 30
Left Arm Angle Vernier : 32.8
Left Arm Scattering Angle : 29.9713
Wien angle : 24.1959
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 527.39
Wien field : 15.34
Laser attenuation Hall A : 234
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88