    User name adev

    Log entry time 07:32:50 on March 1, 2001

    Entry number 57245

    keyword=End_of_Run_2300
    ****************************
     Run Number: 2300
    End of Run Comment:
    RunType=pion_prod,Tar=LD2-15cm,Rad=6,comment=single14,mode=singles,Lmom=2.291,Rmom=-2.291,Ene=4.232,Angle_R=35.194,Angle_L=35.133
    
    Time of run = 4.971224 min
    Av. current (on 3x) = 19.503245 uA
    Av. current (on 1x) = 19.442898 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|    5.7993  |    5.8173  |    5.8281
    up-down    (mC)|   -0.0255  |   -0.0144  |   -0.0041
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 373.76777 Hz  |     19164.4 /mC  |  373.768 Hz  |    111485  |     1   |     19223.9 /mC
        2      | 45953.82 Hz  |   2356214.1 /mC  |   22.977 Hz  |  13706804  |  2000   |   2363527.3 /mC
        3      | 803.37693 Hz  |     41192.0 /mC  |  803.377 Hz  |    239626  |     1   |     41319.8 /mC
        4      | 46412.486 Hz  |   2379731.5 /mC  |   23.206 Hz  |  13843612  |  2000   |   2387117.8 /mC
        5      | 11.985646 Hz  |       614.5 /mC  |   11.986 Hz  |      3575  |     1   |       616.5 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 1.823829 Hz  |        93.5 /mC  |    1.824 Hz  | 543.99989  |     1   |        93.8 /mC
        8    | 1024.0 Hz  |     52504.1 /mC  |    0.016 Hz  |    305432  | 65535   |     52667.0 /mC
        output                       994.004 Hz
    Av. deadtime from accepted triggers = 0.1794
    Av. deadtime from gated scalers = 0.1764
    Accepted triggers  = 296485.00000
    Rate of Left Arm Pulser for electronic DT  = 10.161817
    Rate of Right Arm Pulser for electronic DT  = 0.0
    Rate of Left Arm Pulser&trig for electronic DT  = 10.161817
    Rate of Right Arm Pulser&trig for electronic DT  = 0.0
    Left Arm Electronic DT  = 0.0
    Right Arm Electronic DT  = -1
    Rate of Left Strobe  = 74412.123
    Rate of Right Arm Strobe  = 46443.036
        Signal     |    Charge   (C)   
       upstream    |    0.0057866     
       upstream 3x |    0.0058101     
       upstream 10x|    0.0058261     
      downstream   |    0.0058121   
     downstream 3x |    0.0058245   
     downstream 10x|    0.0058302    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 2300 at Thu Mar  1 07:32:29 EST 2001
    Right Arm D1 momentum                    : 2.291
    Right Arm arm angle                      : 35.1933
    Left Arm D1 momentum                      : 2.291
    Left Arm arm angle                        : 35.1332
    Tiefenbach Hall A energy                : 4234.98
    Right Arm arm mispointing (HPT)          : -1.91572
    Left Arm arm mispointing (HPT)            : 5.2148
    Right Arm Q1 power supply current        : 1722.7
    Right Arm Q1 momentum                    : 2.29102
    Right Arm Q1 gauss meter                 : -0.04283
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 986.159
    Right Arm Q2 momentum                    : 2.29144
    Right Arm Q2 gauss meter                 : 0.5179
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 803.104
    Right Arm D1 momentum                    : 2.291
    Right Arm D1 NMR                         : 0.850162
    Right Arm Q3 power supply current        : 911.708
    Right Arm Q3 momentum                    : 2.29125
    Right Arm Q3 gauss meter                 : 0.4089
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 1723.68
    Left Arm Q1 momentum                      : 2.29112
    Left Arm Q1 gauss meter                   : 0.14643
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 986.635
    Left Arm Q2 momentum                      : 2.2913
    Left Arm Q2 gauss meter                   : -0.5196
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 783.767
    Left Arm D1 momentum                      : 2.291
    Left Arm D1 NMR                           : 0.847757
    Left Arm Q3 power supply current          : 912.003
    Left Arm Q3 momentum                      : 2.29078
    Left Arm Q3 gauss meter                   : 0.4553
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 19.3658
    Current on Unser monitor                : 26.0734
    Current on Upstream bcm                 : 19.508
    Current on Downstream bcm               : 19.2237
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 69.1022
    MBSY1c Hall A Beam energy               : 4243.78
    MBSY1c magnet current (amp)             : 176.909
    MBSY1c Bdl                              : 1.05904e+06
    MBSY3c Hall C Beam energy               : 3406.76
    Tiefenbach Hall A energy                : 4234.98
    Tiefenbach Hall C energy                : 3398.32
    Delta(E)/E width (MV_AI_DXWID)          : 0
    IPM1C12.XPOS                            : -0.0160068
    IPM1H04A.XPOS                           : 0
    IPM1H04A.YPOS                           : 0
    IPM1H04B.XPOS                           : 0
    IPM1H04B.YPOS                           : 0
    Right Arm Arm Collimator                 : 0.61499
    Left Arm Arm Collimator                   : 0.616943
     HacR_HPM_LVDT:VALr                     : -802
     HacR_VPM_LVDT:VALr                     : 630
     HacR_HPE1313A:0_Ch58                   : -0.525391
     HacR_HPE1313A:0_Ch55                   : 22.8027
     HacR_HPE1313A:0_Ch54                   : -0.864258
     HacR_alignROLL                         : -0.383724
     HacR_alignPITCH                        : -0.0293635
     HacR_alignHPT                          : -1.9146
     HacL_HPM_LVDT:VALr                     : -8052
     HacL_VPM_LVDT:VALr                     : 656
     HacL_HPE1313A:0_Ch58                   : -0.16748
     HacL_HPE1313A:0_Ch55                   : 23.6328
     HacL_HPE1313A:0_Ch54                   : -0.230957
     HacL_alignROLL                         : 0.128742
     HacL_alignPITCH                        : -0.0951186
     HacL_alignHPT                          : 5.21596
    haBDSPOS                                 : 3.10127e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 25
    haL3_Fan_frequency_R                     : 37
    haH2_P_Fill_Target_R                     : 24.01
    haH2_P_Exhaust_R                         : 24.69
    haH2_P_Fill_Bottle_R                     : 24.5
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -999.99
    haD2_P_Exhaust_R                         : 20.57
    haD2_P_Fill_Bottle_R                     : 42.39
    haD2_DP_Fill_Exhaust_R                   : 0.0766
    haSC200_6_Sensor_1_R                     : 242.21
    haSC200_6_Sensor_2_R                     : 25.32
    haSC200_6_Sensor_3_R                     : 37.46
    haSC200_6_Sensor_4_R                     : 40.71
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 82.89
    haITC502_1_Sensor_2_R                    : 82.05
    haITC502_1_Sensor_3_R                    : 74.72
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 18.99
    haITC502_2_Sensor_3_R                    : 19.01
    haITC502_4_Sensor_1_R                    : 81.9
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 22
    haITC502_5_Sensor_1_R                    : 87.63
    haITC502_5_Sensor_2_R                    : 81.53
    haITC502_5_Sensor_3_R                    : 269.2
    haITC502_6_Sensor_1_R                    : 94
    haITC502_6_Sensor_2_R                    : 79.1
    haITC502_6_Sensor_3_R                    : 28.23
    Right Arm Arm Collimator                 : 0.615039
    Left Arm Arm Collimator                   : 0.616992
    Wien angle                               : 24.1959
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 527.39
    Wien field                               : 15.34
    Laser attenuation Hall A                 : 199
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : OFF