• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 09:04:04 on March 1, 2001

    Entry number 57258

    keyword=End_of_Run_2304
    ****************************
     Run Number: 2304
    End of Run Comment:
    RunType=pion_prod,Tar=LD2-15cm,Rad=6,comment=single14,mode=singles,Lmom=2.291,Rmom=-2.291,Ene=4.232,Angle_R=35.194,Angle_L=35.133
    
    Time of run = 19.30734 min
    Av. current (on 3x) = 17.303868 uA
    Av. current (on 1x) = 17.249485 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|   19.9825  |   20.0455  |   20.0852
    up-down    (mC)|   -0.0688  |   -0.0401  |   -0.0012
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 327.45146 Hz  |     18923.6 /mC  |  327.451 Hz  |    379333  |     1   |     18983.3 /mC
        2      | 40429.073 Hz  |   2336418.2 /mC  |   20.215 Hz  |  46834672  |  2000   |   2343784.4 /mC
        3      | 708.26087 Hz  |     40930.8 /mC  |  708.261 Hz  |    820478  |     1   |     41059.8 /mC
        4      | 41136.942 Hz  |   2377326.4 /mC  |   20.568 Hz  |  47654696  |  2000   |   2384821.5 /mC
        5      | 11.777904 Hz  |       680.7 /mC  |   11.778 Hz  |     13644  |     1   |       682.8 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 1.601291 Hz  |        92.5 /mC  |    1.601 Hz  | 1855.0004  |     1   |        92.8 /mC
        8    | 1024.0 Hz  |     59177.5 /mC  |    0.016 Hz  |   1186243  | 65535   |     59364.1 /mC
        output                       867.067 Hz
    Av. deadtime from accepted triggers = 0.1856
    Av. deadtime from gated scalers = 0.1814
    Accepted triggers  = 1004446.00000
    Rate of Left Arm Pulser for electronic DT  = 10.176613
    Rate of Right Arm Pulser for electronic DT  = 0.0
    Rate of Left Arm Pulser&trig for electronic DT  = 10.176613
    Rate of Right Arm Pulser&trig for electronic DT  = 0.0
    Left Arm Electronic DT  = 0.0
    Right Arm Electronic DT  = -1
    Rate of Left Strobe  = 65877.492
    Rate of Right Arm Strobe  = 40968.256
        Signal     |    Charge   (C)   
       upstream    |    0.0199481     
       upstream 3x |    0.0200255     
       upstream 10x|    0.0200846     
      downstream   |    0.0200169   
     downstream 3x |    0.0200656   
     downstream 10x|    0.0200858    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 2304 at Thu Mar  1 09:03:52 EST 2001
    Right Arm D1 momentum                    : 2.291
    Right Arm arm angle                      : 35.1933
    Left Arm D1 momentum                      : 2.291
    Left Arm arm angle                        : 35.1333
    Tiefenbach Hall A energy                : 4235
    Right Arm arm mispointing (HPT)          : -1.92881
    Left Arm arm mispointing (HPT)            : 5.2062
    Right Arm Q1 power supply current        : 1722.7
    Right Arm Q1 momentum                    : 2.29102
    Right Arm Q1 gauss meter                 : -0.04285
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 986.03
    Right Arm Q2 momentum                    : 2.29113
    Right Arm Q2 gauss meter                 : 0.5178
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 803.093
    Right Arm D1 momentum                    : 2.291
    Right Arm D1 NMR                         : 0.850163
    Right Arm Q3 power supply current        : 911.605
    Right Arm Q3 momentum                    : 2.29099
    Right Arm Q3 gauss meter                 : 0.4089
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 1723.71
    Left Arm Q1 momentum                      : 2.29116
    Left Arm Q1 gauss meter                   : 0.14642
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 986.495
    Left Arm Q2 momentum                      : 2.29098
    Left Arm Q2 gauss meter                   : -0.5196
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 783.772
    Left Arm D1 momentum                      : 2.291
    Left Arm D1 NMR                           : 0.847758
    Left Arm Q3 power supply current          : 912.16
    Left Arm Q3 momentum                      : 2.29118
    Left Arm Q3 gauss meter                   : 0.4553
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 19.3658
    Current on Unser monitor                : 25.7649
    Current on Upstream bcm                 : 19.3773
    Current on Downstream bcm               : 19.3542
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 19.4268
    MBSY1c Hall A Beam energy               : 4243.78
    MBSY1c magnet current (amp)             : 176.909
    MBSY1c Bdl                              : 1.05904e+06
    MBSY3c Hall C Beam energy               : 3406.76
    Tiefenbach Hall A energy                : 4235
    Tiefenbach Hall C energy                : 3398.28
    Delta(E)/E width (MV_AI_DXWID)          : 2.57459
    IPM1C12.XPOS                            : -0.0145708
    IPM1H04A.XPOS                           : -0.18286
    IPM1H04A.YPOS                           : 0.441326
    IPM1H04B.XPOS                           : 0.00839093
    IPM1H04B.YPOS                           : 0.0289127
    Right Arm Arm Collimator                 : 0.615088
    Left Arm Arm Collimator                   : 0.616992
     HacR_HPM_LVDT:VALr                     : -789
     HacR_VPM_LVDT:VALr                     : 644
     HacR_HPE1313A:0_Ch58                   : -0.526367
     HacR_HPE1313A:0_Ch55                   : 22.6562
     HacR_HPE1313A:0_Ch54                   : -0.864746
     HacR_alignROLL                         : -0.384824
     HacR_alignPITCH                        : -0.0283322
     HacR_alignHPT                          : -1.92853
     HacL_HPM_LVDT:VALr                     : -8046
     HacL_VPM_LVDT:VALr                     : 663
     HacL_HPE1313A:0_Ch58                   : -0.16748
     HacL_HPE1313A:0_Ch55                   : 23.5352
     HacL_HPE1313A:0_Ch54                   : -0.229492
     HacL_alignROLL                         : 0.130366
     HacL_alignPITCH                        : -0.0954079
     HacL_alignHPT                          : 5.20736
    haBDSPOS                                 : 3.10127e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 27
    haL3_Fan_frequency_R                     : 37
    haH2_P_Fill_Target_R                     : 24.51
    haH2_P_Exhaust_R                         : 25.23
    haH2_P_Fill_Bottle_R                     : 24.99
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -999.99
    haD2_P_Exhaust_R                         : 20.8
    haD2_P_Fill_Bottle_R                     : 42.86
    haD2_DP_Fill_Exhaust_R                   : 0.0769
    haSC200_6_Sensor_1_R                     : 241.9
    haSC200_6_Sensor_2_R                     : 25.15
    haSC200_6_Sensor_3_R                     : 37.26
    haSC200_6_Sensor_4_R                     : 40.61
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 82.76
    haITC502_1_Sensor_2_R                    : 81.93
    haITC502_1_Sensor_3_R                    : 74.42
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19.02
    haITC502_4_Sensor_1_R                    : 81.7
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 22
    haITC502_5_Sensor_1_R                    : 87.51
    haITC502_5_Sensor_2_R                    : 81.41
    haITC502_5_Sensor_3_R                    : 269
    haITC502_6_Sensor_1_R                    : 93.77
    haITC502_6_Sensor_2_R                    : 78.75
    haITC502_6_Sensor_3_R                    : 28.22
    Right Arm Arm Collimator                 : 0.615088
    Left Arm Arm Collimator                   : 0.616992
    Wien angle                               : 24.1959
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 527.39
    Wien field                               : 15.34
    Laser attenuation Hall A                 : 156
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : OFF