    User name adev

    Log entry time 23:54:21 on March 1, 2001

    Entry number 57335

    keyword=End_of_Run_2335
    ****************************
     Run Number: 2335
    End of Run Comment:
    RunType=pion_prod,Tar=LD2-15cm,Rad=out,comment=coincidence14,mode=coincidence,Lmom=1.949,Rmom=-2.929,Ene=4.232,Angle_R=25.062,Angle_L=39.483
    
    Time of run = 39.633252 min
    Av. current (on 3x) = 29.64409 uA
    Av. current (on 1x) = 29.55578 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|   70.2835  |   70.4935  |   70.6030
    up-down    (mC)|   -0.3288  |   -0.0905  |    0.0018
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 1268.0867 Hz  |     42777.1 /mC  |  126.809 Hz  |   3015504  |    10   |     42904.9 /mC
        2      | 30151.711 Hz  |   1017123.9 /mC  |   20.101 Hz  |  71700621  |  1500   |   1020162.9 /mC
        3      | 888.46987 Hz  |     29971.2 /mC  |  111.059 Hz  |   2112777  |     8   |     30060.8 /mC
        4      | 23530.596 Hz  |    793770.2 /mC  |   23.531 Hz  |  55955641  |  1000   |    796141.9 /mC
        5      | 105.70123 Hz  |      3565.7 /mC  |  105.701 Hz  |    251357  |     1   |      3576.3 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 95.522908 Hz  |      3222.3 /mC  |   95.523 Hz  | 227153.0  |     1   |      3232.0 /mC
        8    | 1024.0 Hz  |     34543.1 /mC  |    0.016 Hz  |   2435067  | 65535   |     34646.4 /mC
        output                       348.626 Hz
    Av. deadtime from accepted triggers = 0.0407
    Av. deadtime from gated scalers = 0.0485
    Accepted triggers  = 829031.00000
    Rate of Left Arm Pulser for electronic DT  = 10.178322
    Rate of Right Arm Pulser for electronic DT  = 0.0
    Rate of Left Arm Pulser&trig for electronic DT  = 10.17706
    Rate of Right Arm Pulser&trig for electronic DT  = 0.0
    Left Arm Electronic DT  = 0.00012394646
    Right Arm Electronic DT  = -1
    Rate of Left Strobe  = 38526.953
    Rate of Right Arm Strobe  = 29916.766
        Signal     |    Charge   (C)   
       upstream    |    0.0701191     
       upstream 3x |    0.0704483     
       upstream 10x|    0.0706039     
      downstream   |    0.0704479   
     downstream 3x |    0.0705388   
     downstream 10x|    0.0706021    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 2335 at Thu Mar  1 23:54:09 EST 2001
    Right Arm D1 momentum                    : 2.929
    Right Arm arm angle                      : 25.0622
    Left Arm D1 momentum                      : 1.949
    Left Arm arm angle                        : 39.4831
    Tiefenbach Hall A energy                : 4235
    Right Arm arm mispointing (HPT)          : -1.8043
    Left Arm arm mispointing (HPT)            : 5.44912
    Right Arm Q1 power supply current        : 2202.34
    Right Arm Q1 momentum                    : 2.9289
    Right Arm Q1 gauss meter                 : -0.05471
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 1260.63
    Right Arm Q2 momentum                    : 2.9292
    Right Arm Q2 gauss meter                 : 0.6617
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 1048.45
    Right Arm D1 momentum                    : 2.929
    Right Arm D1 NMR                         : 1.08692
    Right Arm Q3 power supply current        : 1165.26
    Right Arm Q3 momentum                    : 2.92845
    Right Arm Q3 gauss meter                 : 0.5226
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 1466.29
    Left Arm Q1 momentum                      : 1.94899
    Left Arm Q1 gauss meter                   : 0.12468
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 839.213
    Left Arm Q2 momentum                      : 1.94894
    Left Arm Q2 gauss meter                   : -0.4422
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 659.631
    Left Arm D1 momentum                      : 1.949
    Left Arm D1 NMR                           : 0.72121
    Left Arm Q3 power supply current          : 775.678
    Left Arm Q3 momentum                      : 1.94836
    Left Arm Q3 gauss meter                   : 0.3874
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 30.2228
    Current on Unser monitor                : 37.6418
    Current on Upstream bcm                 : 30.2138
    Current on Downstream bcm               : 30.2317
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 99.1555
    MBSY1c Hall A Beam energy               : 4243.78
    MBSY1c magnet current (amp)             : 176.909
    MBSY1c Bdl                              : 1.05904e+06
    MBSY3c Hall C Beam energy               : 3406.76
    Tiefenbach Hall A energy                : 4235.03
    Tiefenbach Hall C energy                : 3397.97
    Delta(E)/E width (MV_AI_DXWID)          : 2.38486
    IPM1C12.XPOS                            : -0.00266767
    IPM1H04A.XPOS                           : -0.126699
    IPM1H04A.YPOS                           : 0.454786
    IPM1H04B.XPOS                           : 0.062034
    IPM1H04B.YPOS                           : 0.0469199
    Right Arm Arm Collimator                 : 0.615088
    Left Arm Arm Collimator                   : 0.616992
     HacR_HPM_LVDT:VALr                     : -916
     HacR_VPM_LVDT:VALr                     : 196
     HacR_HPE1313A:0_Ch58                   : -0.533203
     HacR_HPE1313A:0_Ch55                   : 22.7539
     HacR_HPE1313A:0_Ch54                   : -0.793457
     HacR_alignROLL                         : -0.312296
     HacR_alignPITCH                        : -0.023012
     HacR_alignHPT                          : -1.80343
     HacL_HPM_LVDT:VALr                     : -8264
     HacL_VPM_LVDT:VALr                     : 144
     HacL_HPE1313A:0_Ch58                   : -0.195801
     HacL_HPE1313A:0_Ch55                   : 23.5352
     HacL_HPE1313A:0_Ch54                   : -0.259277
     HacL_alignROLL                         : 0.10305
     HacL_alignPITCH                        : -0.0697215
     HacL_alignHPT                          : 5.45135
    haBDSPOS                                 : 3.10127e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 25
    haL3_Fan_frequency_R                     : 37
    haH2_P_Fill_Target_R                     : 23.97
    haH2_P_Exhaust_R                         : 24.7
    haH2_P_Fill_Bottle_R                     : 24.51
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -999.99
    haD2_P_Exhaust_R                         : 20.6
    haD2_P_Fill_Bottle_R                     : 42.58
    haD2_DP_Fill_Exhaust_R                   : 0.0768
    haSC200_6_Sensor_1_R                     : 242
    haSC200_6_Sensor_2_R                     : 25.27
    haSC200_6_Sensor_3_R                     : 37.24
    haSC200_6_Sensor_4_R                     : 40.63
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 82.8
    haITC502_1_Sensor_2_R                    : 81.95
    haITC502_1_Sensor_3_R                    : 74.53
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 18.99
    haITC502_2_Sensor_3_R                    : 19.02
    haITC502_4_Sensor_1_R                    : 81.9
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 22
    haITC502_5_Sensor_1_R                    : 87.52
    haITC502_5_Sensor_2_R                    : 81.45
    haITC502_5_Sensor_3_R                    : 268.8
    haITC502_6_Sensor_1_R                    : 93.89
    haITC502_6_Sensor_2_R                    : 79.18
    haITC502_6_Sensor_3_R                    : 28.18
    Right Arm Arm Collimator                 : 0.615088
    Left Arm Arm Collimator                   : 0.616992
    Wien angle                               : 24.1959
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 527.39
    Wien field                               : 15.34
    Laser attenuation Hall A                 : 212
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : OFF