    User name adev

    Log entry time 23:50:05 on March 2, 2001

    Entry number 57451

    keyword=End_of_Run_2385
    ****************************
     Run Number: 2385
    End of Run Comment:
    RunType=Harp,Tar=9foil-12C,Rad=out,comment=single13,mode=singles,Lmom=2.929,Rmom=-2.929,Ene=4.232,Angle_R=25.062,Angle_L=25.023
    
    Time of run = 0.57638347 min
    Av. current (on 3x) = 5.0371558 uA
    Av. current (on 1x) = 5.0140231 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|    0.1734  |    0.1742  |    0.1749
    up-down    (mC)|    0.0007  |   -0.0010  |    0.0000
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 18.390534 Hz  |      3651.0 /mC  |   18.391 Hz  |       636  |     1   |      3667.8 /mC
        2      | 2406.5287 Hz  |    477755.5 /mC  |    2.407 Hz  |     83225  |  1000   |    479959.6 /mC
        3      | 34.005139 Hz  |      6750.9 /mC  |   34.005 Hz  |      1176  |     1   |      6782.0 /mC
        4      | 1873.261 Hz  |    371888.6 /mC  |    1.873 Hz  |     64783  |  1000   |    373604.4 /mC
        5      | 10.178409 Hz  |      2020.7 /mC  |   10.178 Hz  |       352  |     1   |      2030.0 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 0.0 Hz  |         0.0 /mC  |    0.000 Hz  | 1.2572798e-07  |     1   |         0.0 /mC
        8    | 1024.0 Hz  |    203289.3 /mC  |    0.016 Hz  |     35413  | 65535   |    204227.2 /mC
        output                        46.034 Hz
    Av. deadtime from accepted triggers = 0.0103
    Av. deadtime from gated scalers = 0.0063
    Accepted triggers  =   1592.00000
    Rate of Left Arm Pulser for electronic DT  = 10.178409
    Rate of Right Arm Pulser for electronic DT  = 0.0
    Rate of Left Arm Pulser&trig for electronic DT  = 10.178409
    Rate of Right Arm Pulser&trig for electronic DT  = 0.0
    Left Arm Electronic DT  = 0.0
    Right Arm Electronic DT  = -1
    Rate of Left Strobe  = 3273.891
    Rate of Right Arm Strobe  = 2378.8561
        Signal     |    Charge   (C)   
       upstream    |    0.0001738     
       upstream 3x |    0.0001737     
       upstream 10x|    0.0001749     
      downstream   |    0.0001731   
     downstream 3x |    0.0001747   
     downstream 10x|    0.0001749    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 2385 at Fri Mar  2 23:49:54 EST 2001
    Right Arm D1 momentum                    : 2.67079
    Right Arm arm angle                      : 41.3438
    Left Arm D1 momentum                      : 1.967
    Left Arm arm angle                        : 41.3228
    Tiefenbach Hall A energy                : 4235
    Right Arm arm mispointing (HPT)          : 2.36428
    Left Arm arm mispointing (HPT)            : 5.51302
    Right Arm Q1 power supply current        : 1479.06
    Right Arm Q1 momentum                    : 1.96701
    Right Arm Q1 gauss meter                 : -0.03683
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 846.606
    Right Arm Q2 momentum                    : 1.96717
    Right Arm Q2 gauss meter                 : 0.4448
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 910.931
    Right Arm D1 momentum                    : 2.67042
    Right Arm D1 NMR                         : 0.990962
    Right Arm Q3 power supply current        : 782.712
    Right Arm Q3 momentum                    : 1.96706
    Right Arm Q3 gauss meter                 : 0.351
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 1479.8
    Left Arm Q1 momentum                      : 1.96695
    Left Arm Q1 gauss meter                   : 0.12587
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 847.047
    Left Arm Q2 momentum                      : 1.96713
    Left Arm Q2 gauss meter                   : -0.4463
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 665.967
    Left Arm D1 momentum                      : 1.96699
    Left Arm D1 NMR                           : 0.727862
    Left Arm Q3 power supply current          : 783.163
    Left Arm Q3 momentum                      : 1.96716
    Left Arm Q3 gauss meter                   : 0.391
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 5.07036
    Current on Unser monitor                : 11.0981
    Current on Upstream bcm                 : 5.08097
    Current on Downstream bcm               : 5.05975
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 78.355
    MBSY1c Hall A Beam energy               : 4243.78
    MBSY1c magnet current (amp)             : 176.909
    MBSY1c Bdl                              : 1.05904e+06
    MBSY3c Hall C Beam energy               : 3406.76
    Tiefenbach Hall A energy                : 4235
    Tiefenbach Hall C energy                : 3398.09
    Delta(E)/E width (MV_AI_DXWID)          : 1.07128
    IPM1C12.XPOS                            : -0.0257222
    IPM1H04A.XPOS                           : -0.540339
    IPM1H04A.YPOS                           : 0.438102
    IPM1H04B.XPOS                           : 0.0133854
    IPM1H04B.YPOS                           : 0.0237517
    Right Arm Arm Collimator                 : 0.615088
    Left Arm Arm Collimator                   : 0.616943
     HacR_HPM_LVDT:VALr                     : -4598
     HacR_VPM_LVDT:VALr                     : 741
     HacR_HPE1313A:0_Ch58                   : -0.527344
     HacR_HPE1313A:0_Ch55                   : 22.8027
     HacR_HPE1313A:0_Ch54                   : -0.91748
     HacR_alignROLL                         : -0.437463
     HacR_alignPITCH                        : -0.0275678
     HacR_alignHPT                          : 2.36375
     HacL_HPM_LVDT:VALr                     : -8323
     HacL_VPM_LVDT:VALr                     : -139
     HacL_HPE1313A:0_Ch58                   : -0.217285
     HacL_HPE1313A:0_Ch55                   : 23.5352
     HacL_HPE1313A:0_Ch54                   : -0.246582
     HacL_alignROLL                         : 0.115048
     HacL_alignPITCH                        : -0.0510198
     HacL_alignHPT                          : 5.51375
    haBDSPOS                                 : 2.50444e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 38
    haL3_Fan_frequency_R                     : 29.5
    haH2_P_Fill_Target_R                     : 24.11
    haH2_P_Exhaust_R                         : 24.72
    haH2_P_Fill_Bottle_R                     : 24.56
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -999.99
    haD2_P_Exhaust_R                         : 20.7
    haD2_P_Fill_Bottle_R                     : 42.79
    haD2_DP_Fill_Exhaust_R                   : 0.0769
    haSC200_6_Sensor_1_R                     : 241.74
    haSC200_6_Sensor_2_R                     : 25.2
    haSC200_6_Sensor_3_R                     : 37.26
    haSC200_6_Sensor_4_R                     : 40.49
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 82.88
    haITC502_1_Sensor_2_R                    : 82.02
    haITC502_1_Sensor_3_R                    : 74.98
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 18.99
    haITC502_2_Sensor_3_R                    : 19
    haITC502_4_Sensor_1_R                    : 81.8
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 21.9
    haITC502_5_Sensor_1_R                    : 87.73
    haITC502_5_Sensor_2_R                    : 81.54
    haITC502_5_Sensor_3_R                    : 269.5
    haITC502_6_Sensor_1_R                    : 94.13
    haITC502_6_Sensor_2_R                    : 79.16
    haITC502_6_Sensor_3_R                    : 28.17
    Right Arm Arm Collimator                 : 0.615088
    Left Arm Arm Collimator                   : 0.616992
    Wien angle                               : 45.4996
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 1016.1
    Wien field                               : 29.657
    Laser attenuation Hall A                 : 93
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : ON