• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 03:30:33 on March 3, 2001

    Entry number 57491

    keyword=End_of_Run_2389
    ****************************
     Run Number: 2389
    End of Run Comment:
    RunType=Harp,Tar=9foil-12C,Rad=out,comment=single13,mode=singles,Lmom=2.929,Rmom=-2.929,Ene=4.232,Angle_R=25.062,Angle_L=25.023
    
    Time of run = 0.43305663 min
    Av. current (on 3x) = 5.2649003 uA
    Av. current (on 1x) = 5.23796 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|    0.1361  |    0.1368  |    0.1373
    up-down    (mC)|    0.0005  |   -0.0009  |   -0.0001
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 18.781223 Hz  |      3567.3 /mC  |   18.781 Hz  |       488  |     1   |      3585.6 /mC
        2      | 2418.8137 Hz  |    459422.5 /mC  |    2.419 Hz  |     62849  |  1000   |    461785.5 /mC
        3      | 35.407224 Hz  |      6725.1 /mC  |   35.407 Hz  |       920  |     1   |      6759.7 /mC
        4      | 1879.7003 Hz  |    357024.8 /mC  |    1.880 Hz  |     48841  |  1000   |    358861.1 /mC
        5      | 10.19882 Hz  |      1937.1 /mC  |   10.199 Hz  |       265  |     1   |      1947.1 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 0.0 Hz  |         0.0 /mC  |    0.000 Hz  | 8.0964003e-07  |     1   |         0.0 /mC
        8    | 1024.0 Hz  |    194495.6 /mC  |    0.016 Hz  |     26607  | 65535   |    195496.0 /mC
        output                        47.915 Hz
    Av. deadtime from accepted triggers = 0.0081
    Av. deadtime from gated scalers = 0.0065
    Accepted triggers  =   1245.00000
    Rate of Left Arm Pulser for electronic DT  = 10.19882
    Rate of Right Arm Pulser for electronic DT  = 0.0
    Rate of Left Arm Pulser&trig for electronic DT  = 10.19882
    Rate of Right Arm Pulser&trig for electronic DT  = 0.0
    Left Arm Electronic DT  = 0.0
    Right Arm Electronic DT  = -1
    Rate of Left Strobe  = 3284.9052
    Rate of Right Arm Strobe  = 2460.3018
        Signal     |    Charge   (C)   
       upstream    |    0.0001364     
       upstream 3x |    0.0001363     
       upstream 10x|    0.0001372     
      downstream   |    0.0001359   
     downstream 3x |    0.0001372   
     downstream 10x|    0.0001373    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 2389 at Sat Mar  3 00:01:07 EST 2001
    Right Arm D1 momentum                    : 2.54971
    Right Arm arm angle                      : 41.3437
    Left Arm D1 momentum                      : 1.96701
    Left Arm arm angle                        : 41.3228
    Tiefenbach Hall A energy                : 4235.01
    Right Arm arm mispointing (HPT)          : 2.38599
    Left Arm arm mispointing (HPT)            : 5.51649
    Right Arm Q1 power supply current        : 1478.96
    Right Arm Q1 momentum                    : 1.96678
    Right Arm Q1 gauss meter                 : -0.03685
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 846.708
    Right Arm Q2 momentum                    : 1.96696
    Right Arm Q2 gauss meter                 : 0.4449
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 778.128
    Right Arm D1 momentum                    : 2.31526
    Right Arm D1 NMR                         : 0.856768
    Right Arm Q3 power supply current        : 782.947
    Right Arm Q3 momentum                    : 1.96745
    Right Arm Q3 gauss meter                 : 0.3509
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 1479.91
    Left Arm Q1 momentum                      : 1.96718
    Left Arm Q1 gauss meter                   : 0.12586
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 847.153
    Left Arm Q2 momentum                      : 1.96648
    Left Arm Q2 gauss meter                   : -0.4463
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 665.991
    Left Arm D1 momentum                      : 1.96699
    Left Arm D1 NMR                           : 0.727868
    Left Arm Q3 power supply current          : 783.01
    Left Arm Q3 momentum                      : 1.96683
    Left Arm Q3 gauss meter                   : 0.391
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 19.4313
    Current on Unser monitor                : 6.27529
    Current on Upstream bcm                 : 0.163674
    Current on Downstream bcm               : 17.8236
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 91.5012
    MBSY1c Hall A Beam energy               : 4243.78
    MBSY1c magnet current (amp)             : 176.909
    MBSY1c Bdl                              : 1.05904e+06
    MBSY3c Hall C Beam energy               : 3406.76
    Tiefenbach Hall A energy                : 4235.03
    Tiefenbach Hall C energy                : 3398.18
    Delta(E)/E width (MV_AI_DXWID)          : 1.05014
    IPM1C12.XPOS                            : 0.013773
    IPM1H04A.XPOS                           : 0
    IPM1H04A.YPOS                           : 0
    IPM1H04B.XPOS                           : 0
    IPM1H04B.YPOS                           : 0
    Right Arm Arm Collimator                 : 0.615088
    Left Arm Arm Collimator                   : 0.617041
     HacR_HPM_LVDT:VALr                     : -4633
     HacR_VPM_LVDT:VALr                     : 777
     HacR_HPE1313A:0_Ch58                   : -0.522461
     HacR_HPE1313A:0_Ch55                   : 22.8027
     HacR_HPE1313A:0_Ch54                   : -0.938477
     HacR_alignROLL                         : -0.458662
     HacR_alignPITCH                        : -0.032057
     HacR_alignHPT                          : 2.41579
     HacL_HPM_LVDT:VALr                     : -8311
     HacL_VPM_LVDT:VALr                     : -87
     HacL_HPE1313A:0_Ch58                   : -0.210449
     HacL_HPE1313A:0_Ch55                   : 23.584
     HacL_HPE1313A:0_Ch54                   : -0.230957
     HacL_alignROLL                         : 0.127859
     HacL_alignPITCH                        : -0.0566959
     HacL_alignHPT                          : 5.49419
    haBDSPOS                                 : 3.10127e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 25.5
    haL3_Fan_frequency_R                     : 37
    haH2_P_Fill_Target_R                     : 24.18
    haH2_P_Exhaust_R                         : 24.87
    haH2_P_Fill_Bottle_R                     : 24.67
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -999.99
    haD2_P_Exhaust_R                         : 20.66
    haD2_P_Fill_Bottle_R                     : 42.64
    haD2_DP_Fill_Exhaust_R                   : 0.0771
    haSC200_6_Sensor_1_R                     : 241.86
    haSC200_6_Sensor_2_R                     : 25.09
    haSC200_6_Sensor_3_R                     : 37.26
    haSC200_6_Sensor_4_R                     : 40.56
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 83.02
    haITC502_1_Sensor_2_R                    : 82.17
    haITC502_1_Sensor_3_R                    : 74.74
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19.03
    haITC502_4_Sensor_1_R                    : 82
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 22
    haITC502_5_Sensor_1_R                    : 87.71
    haITC502_5_Sensor_2_R                    : 81.67
    haITC502_5_Sensor_3_R                    : 268.4
    haITC502_6_Sensor_1_R                    : 94.18
    haITC502_6_Sensor_2_R                    : 79.34
    haITC502_6_Sensor_3_R                    : 28.15
    Right Arm Arm Collimator                 : 0.615088
    Left Arm Arm Collimator                   : 0.616992
    Wien angle                               : 45.4996
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 1016.1
    Wien field                               : 29.657
    Laser attenuation Hall A                 : 183
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : ON