• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 06:10:56 on March 4, 2001

    Entry number 57601

    keyword=End_of_Run_2452
    ****************************
     Run Number: 2452
    End of Run Comment:
    RunType=pion_prod,Tar=LH2-15cm,Rad=out,comment=15_singles,mode=singles,Lmom=1.967,Rmom=-1.967,Ene=4.232,Angle_R=41.323,Angle_L=41.343
    
    Time of run = 49.702882 min
    Av. current (on 3x) = 37.924562 uA
    Av. current (on 1x) = 37.818867 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|  112.7824  |  113.0976  |  113.2364
    up-down    (mC)|   -0.5703  |   -0.1244  |    0.0089
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 91.940679 Hz  |      2424.3 /mC  |   91.941 Hz  |    274183  |     1   |      2431.1 /mC
        2      | 17751.045 Hz  |    468062.0 /mC  |    5.917 Hz  |  52936685  |  3000   |    469370.1 /mC
        3      | 264.74723 Hz  |      6980.9 /mC  |  264.747 Hz  |    789522  |     1   |      7000.4 /mC
        4      | 17041.235 Hz  |    449345.6 /mC  |    5.680 Hz  |  50819908  |  3000   |    450601.4 /mC
        5      | 10.178149 Hz  |       268.4 /mC  |   10.178 Hz  |     30353  |     1   |       269.1 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 0.000671 Hz  |         0.0 /mC  |    0.001 Hz  | 2.0009181  |     1   |         0.0 /mC
        8    | 1024.0 Hz  |     27001.0 /mC  |    0.016 Hz  |   3053745  | 65535   |     27076.4 /mC
        output                       335.110 Hz
    Av. deadtime from accepted triggers = 0.0643
    Av. deadtime from gated scalers = 0.0598
    Accepted triggers  = 999356.00000
    Rate of Left Arm Pulser for electronic DT  = 10.177478
    Rate of Right Arm Pulser for electronic DT  = 0.0
    Rate of Left Arm Pulser&trig for electronic DT  = 10.177143
    Rate of Right Arm Pulser&trig for electronic DT  = 0.0
    Left Arm Electronic DT  = 3.2947844e-05
    Right Arm Electronic DT  = -1
    Rate of Left Strobe  = 27282.602
    Rate of Right Arm Strobe  = 17236.859
        Signal     |    Charge   (C)   
       upstream    |    0.1124973     
       upstream 3x |    0.1130354     
       upstream 10x|    0.1132408     
      downstream   |    0.1130676   
     downstream 3x |    0.1131598   
     downstream 10x|    0.1132319    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 2452 at Sun Mar  4 06:10:38 EST 2001
    Right Arm D1 momentum                    : 1.967
    Right Arm arm angle                      : 41.3435
    Left Arm D1 momentum                      : 1.967
    Left Arm arm angle                        : 41.3232
    Tiefenbach Hall A energy                : 4235.04
    Right Arm arm mispointing (HPT)          : 2.40281
    Left Arm arm mispointing (HPT)            : 5.46574
    Right Arm Q1 power supply current        : 1478.89
    Right Arm Q1 momentum                    : 1.96678
    Right Arm Q1 gauss meter                 : -0.03685
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 846.583
    Right Arm Q2 momentum                    : 1.96712
    Right Arm Q2 gauss meter                 : 0.4448
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 680.845
    Right Arm D1 momentum                    : 1.967
    Right Arm D1 NMR                         : 0.72993
    Right Arm Q3 power supply current        : 782.701
    Right Arm Q3 momentum                    : 1.96704
    Right Arm Q3 gauss meter                 : 0.351
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 1479.91
    Left Arm Q1 momentum                      : 1.96709
    Left Arm Q1 gauss meter                   : 0.12587
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 846.922
    Left Arm Q2 momentum                      : 1.96684
    Left Arm Q2 gauss meter                   : -0.4463
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 665.993
    Left Arm D1 momentum                      : 1.967
    Left Arm D1 NMR                           : 0.727864
    Left Arm Q3 power supply current          : 782.968
    Left Arm Q3 momentum                      : 1.96667
    Left Arm Q3 gauss meter                   : 0.391
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 37.8075
    Current on Unser monitor                : 44.7705
    Current on Upstream bcm                 : 38.2842
    Current on Downstream bcm               : 38.2391
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 104.357
    MBSY1c Hall A Beam energy               : 4243.78
    MBSY1c magnet current (amp)             : 176.909
    MBSY1c Bdl                              : 1.05904e+06
    MBSY3c Hall C Beam energy               : 3406.76
    Tiefenbach Hall A energy                : 4235.04
    Tiefenbach Hall C energy                : 3397.95
    Delta(E)/E width (MV_AI_DXWID)          : 1.06957
    IPM1C12.XPOS                            : -0.00188997
    IPM1H04A.XPOS                           : -0.453495
    IPM1H04A.YPOS                           : 0.200415
    IPM1H04B.XPOS                           : 0.0448262
    IPM1H04B.YPOS                           : -0.0327278
    Right Arm Arm Collimator                 : 0.615088
    Left Arm Arm Collimator                   : 0.616943
     HacR_HPM_LVDT:VALr                     : -4618
     HacR_VPM_LVDT:VALr                     : 828
     HacR_HPE1313A:0_Ch58                   : -0.52002
     HacR_HPE1313A:0_Ch55                   : 22.8027
     HacR_HPE1313A:0_Ch54                   : -0.946289
     HacR_alignROLL                         : -0.467044
     HacR_alignPITCH                        : -0.0343016
     HacR_alignHPT                          : 2.40281
     HacL_HPM_LVDT:VALr                     : -8290
     HacL_VPM_LVDT:VALr                     : -55
     HacL_HPE1313A:0_Ch58                   : -0.209961
     HacL_HPE1313A:0_Ch55                   : 23.584
     HacL_HPE1313A:0_Ch54                   : -0.226074
     HacL_alignROLL                         : 0.13316
     HacL_alignPITCH                        : -0.0571325
     HacL_alignHPT                          : 5.46595
    haBDSPOS                                 : 4.643e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 66
    haL3_Fan_frequency_R                     : 25
    haH2_P_Fill_Target_R                     : 24.33
    haH2_P_Exhaust_R                         : 24.69
    haH2_P_Fill_Bottle_R                     : 24.8
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -999.99
    haD2_P_Exhaust_R                         : 20.98
    haD2_P_Fill_Bottle_R                     : 43.18
    haD2_DP_Fill_Exhaust_R                   : 0.0768
    haSC200_6_Sensor_1_R                     : 241.73
    haSC200_6_Sensor_2_R                     : 25.29
    haSC200_6_Sensor_3_R                     : 37.29
    haSC200_6_Sensor_4_R                     : 40.56
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 83.69
    haITC502_1_Sensor_2_R                    : 82.84
    haITC502_1_Sensor_3_R                    : 75.49
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 18.99
    haITC502_2_Sensor_3_R                    : 19.11
    haITC502_4_Sensor_1_R                    : 82.4
    haITC502_4_Sensor_2_R                    : 19.1
    haITC502_4_Sensor_3_R                    : 21.9
    haITC502_5_Sensor_1_R                    : 88.34
    haITC502_5_Sensor_2_R                    : 82.29
    haITC502_5_Sensor_3_R                    : 266.8
    haITC502_6_Sensor_1_R                    : 94.62
    haITC502_6_Sensor_2_R                    : 79.67
    haITC502_6_Sensor_3_R                    : 28.14
    Right Arm Arm Collimator                 : 0.615088
    Left Arm Arm Collimator                   : 0.616943
    Wien angle                               : 45.4996
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 1016.1
    Wien field                               : 29.657
    Laser attenuation Hall A                 : 258
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : ON