    User name adev

    Log entry time 06:35:30 on March 4, 2001

    Entry number 57603

    keyword=End_of_Run_2453
    ****************************
     Run Number: 2453
    End of Run Comment:
    RunType=pion_prod,Tar=absence,Rad=out,comment=15_singles,mode=singles,Lmom=1.967,Rmom=-1.967,Ene=4.232,Angle_R=41.323,Angle_L=41.343
    
    Time of run = 15.915804 min
    Av. current (on 3x) = 38.531617 uA
    Av. current (on 1x) = 38.424072 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|   36.6930  |   36.7957  |   36.8406
    up-down    (mC)|   -0.1808  |   -0.0342  |    0.0081
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 22.671386 Hz  |       588.4 /mC  |   22.671 Hz  |     21650  |     1   |       590.0 /mC
        2      | 4654.5161 Hz  |    120797.3 /mC  |    1.552 Hz  |   4444822  |  3000   |    121135.4 /mC
        3      | 20.869194 Hz  |       541.6 /mC  |   20.869 Hz  |     19929  |     1   |       543.1 /mC
        4      | 4317.2633 Hz  |    112044.7 /mC  |    1.439 Hz  |   4122763  |  3000   |    112358.3 /mC
        5      | 10.177515 Hz  |       264.1 /mC  |   10.178 Hz  |      9719  |     1   |       264.9 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 0.0 Hz  |        -0.0 /mC  |    0.000 Hz  | -3.68236e-05  |     1   |        -0.0 /mC
        8    | 1024.0 Hz  |     26575.6 /mC  |    0.016 Hz  |    977867  | 65535   |     26650.0 /mC
        output                        36.112 Hz
    Av. deadtime from accepted triggers = 0.0071
    Av. deadtime from gated scalers = 0.0065
    Accepted triggers  =  34485.00000
    Rate of Left Arm Pulser for electronic DT  = 10.177515
    Rate of Right Arm Pulser for electronic DT  = 0.0
    Rate of Left Arm Pulser&trig for electronic DT  = 10.177515
    Rate of Right Arm Pulser&trig for electronic DT  = 0.0
    Left Arm Electronic DT  = 0.0
    Right Arm Electronic DT  = -1
    Rate of Left Strobe  = 6945.9765
    Rate of Right Arm Strobe  = 4512.8184
        Signal     |    Charge   (C)   
       upstream    |    0.0366026     
       upstream 3x |    0.0367786     
       upstream 10x|    0.0368447     
      downstream   |    0.0367834   
     downstream 3x |    0.0368128   
     downstream 10x|    0.0368366    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 2453 at Sun Mar  4 06:35:18 EST 2001
    Right Arm D1 momentum                    : 1.967
    Right Arm arm angle                      : 41.3435
    Left Arm D1 momentum                      : 1.96699
    Left Arm arm angle                        : 41.3231
    Tiefenbach Hall A energy                : 4235.03
    Right Arm arm mispointing (HPT)          : 2.40617
    Left Arm arm mispointing (HPT)            : 5.47021
    Right Arm Q1 power supply current        : 1478.85
    Right Arm Q1 momentum                    : 1.96673
    Right Arm Q1 gauss meter                 : -0.03684
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 846.377
    Right Arm Q2 momentum                    : 1.96664
    Right Arm Q2 gauss meter                 : 0.4447
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 680.857
    Right Arm D1 momentum                    : 1.967
    Right Arm D1 NMR                         : 0.729929
    Right Arm Q3 power supply current        : 782.53
    Right Arm Q3 momentum                    : 1.96661
    Right Arm Q3 gauss meter                 : 0.3511
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 1479.91
    Left Arm Q1 momentum                      : 1.96709
    Left Arm Q1 gauss meter                   : 0.12588
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 847.132
    Left Arm Q2 momentum                      : 1.96733
    Left Arm Q2 gauss meter                   : -0.4464
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 665.995
    Left Arm D1 momentum                      : 0
    Left Arm D1 NMR                           : 0.727864
    Left Arm Q3 power supply current          : 783.144
    Left Arm Q3 momentum                      : 1.96713
    Left Arm Q3 gauss meter                   : 0.391
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 38.5356
    Current on Unser monitor                : 46.0088
    Current on Upstream bcm                 : 38.3788
    Current on Downstream bcm               : 38.6925
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 101.169
    MBSY1c Hall A Beam energy               : 4243.78
    MBSY1c magnet current (amp)             : 176.909
    MBSY1c Bdl                              : 1.05904e+06
    MBSY3c Hall C Beam energy               : 3406.76
    Tiefenbach Hall A energy                : 4235.03
    Tiefenbach Hall C energy                : 3397.97
    Delta(E)/E width (MV_AI_DXWID)          : 1.07915
    IPM1C12.XPOS                            : 0.0156917
    IPM1H04A.XPOS                           : -0.476367
    IPM1H04A.YPOS                           : 0.0834124
    IPM1H04B.XPOS                           : 0.0525043
    IPM1H04B.YPOS                           : -0.209233
    Right Arm Arm Collimator                 : 0.615137
    Left Arm Arm Collimator                   : 0.616943
     HacR_HPM_LVDT:VALr                     : -4622
     HacR_VPM_LVDT:VALr                     : 845
     HacR_HPE1313A:0_Ch58                   : -0.520996
     HacR_HPE1313A:0_Ch55                   : 22.7539
     HacR_HPE1313A:0_Ch54                   : -0.946289
     HacR_alignROLL                         : -0.466606
     HacR_alignPITCH                        : -0.0346837
     HacR_alignHPT                          : 2.407
     HacL_HPM_LVDT:VALr                     : -8294
     HacL_VPM_LVDT:VALr                     : -40
     HacL_HPE1313A:0_Ch58                   : -0.209961
     HacL_HPE1313A:0_Ch55                   : 23.584
     HacL_HPE1313A:0_Ch54                   : -0.226074
     HacL_alignROLL                         : 0.133673
     HacL_alignPITCH                        : -0.0572052
     HacL_alignHPT                          : 5.46794
    haBDSPOS                                 : -44998
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 29
    haL3_Fan_frequency_R                     : 24.5
    haH2_P_Fill_Target_R                     : 24.38
    haH2_P_Exhaust_R                         : 25.01
    haH2_P_Fill_Bottle_R                     : 24.85
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -999.99
    haD2_P_Exhaust_R                         : 21.01
    haD2_P_Fill_Bottle_R                     : 43.24
    haD2_DP_Fill_Exhaust_R                   : 0.0769
    haSC200_6_Sensor_1_R                     : 241.69
    haSC200_6_Sensor_2_R                     : 25.25
    haSC200_6_Sensor_3_R                     : 37.26
    haSC200_6_Sensor_4_R                     : 40.56
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 83.66
    haITC502_1_Sensor_2_R                    : 82.8
    haITC502_1_Sensor_3_R                    : 75.85
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19.02
    haITC502_4_Sensor_1_R                    : 82.3
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 21.9
    haITC502_5_Sensor_1_R                    : 88.29
    haITC502_5_Sensor_2_R                    : 82.27
    haITC502_5_Sensor_3_R                    : 272
    haITC502_6_Sensor_1_R                    : 94.69
    haITC502_6_Sensor_2_R                    : 79.78
    haITC502_6_Sensor_3_R                    : 28.39
    Right Arm Arm Collimator                 : 0.615137
    Left Arm Arm Collimator                   : 0.616992
    Wien angle                               : 45.4996
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 1016.1
    Wien field                               : 29.657
    Laser attenuation Hall A                 : 259
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : ON