    User name adev

    Log entry time 17:38:17 on March 4, 2001

    Entry number 57664

    keyword=End_of_Run_2479
    ****************************
     Run Number: 2479
    End of Run Comment:
    RunType=pion_prod,Tar=dum-15cm,Rad=6,comment=4_single,mode=singles,Lmom=1.433,Rmom=-1.433,Ene=1.723,Angle_R=24.474,Angle_L=24.434
    
    
    Time of run = 9.8110515 min
    Av. current (on 3x) = 8.8011294 uA
    Av. current (on 1x) = 8.7654553 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|    5.1599  |    5.1809  |    5.1958
    up-down    (mC)|    0.0014  |   -0.0169  |    0.0016
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 2769.7269 Hz  |    314701.3 /mC  |  110.789 Hz  |   1630436  |    25   |    315982.1 /mC
        2      | 21593.474 Hz  |   2453489.0 /mC  |   77.120 Hz  |  12711281  |   280   |   2463474.3 /mC
        3      | 2777.83 Hz  |    315622.0 /mC  |  111.113 Hz  |   1635206  |    25   |    316906.5 /mC
        4      | 21773.466 Hz  |   2473940.0 /mC  |   98.970 Hz  |  12817236  |   220   |   2484008.6 /mC
        5      | 10.860202 Hz  |      1234.0 /mC  |   10.860 Hz  |      6393  |     1   |      1239.0 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 0.67441 Hz  |        76.6 /mC  |    0.674 Hz  | 397.00021  |     1   |        76.9 /mC
        8    | 1024.0 Hz  |    116348.7 /mC  |    0.016 Hz  |    602791  | 65535   |    116822.2 /mC
        output                       373.385 Hz
    Av. deadtime from accepted triggers = 0.0848
    Av. deadtime from gated scalers = 0.1017
    Accepted triggers  = 219798.00000
    Rate of Left Arm Pulser for electronic DT  = 10.185792
    Rate of Right Arm Pulser for electronic DT  = 0.0
    Rate of Left Arm Pulser&trig for electronic DT  = 10.184094
    Rate of Right Arm Pulser&trig for electronic DT  = 0.0
    Left Arm Electronic DT  = 0.00016677785
    Right Arm Electronic DT  = -1
    Rate of Left Strobe  = 38825.099
    Rate of Right Arm Strobe  = 24411.131
        Signal     |    Charge   (C)   
       upstream    |    0.0051606     
       upstream 3x |    0.0051724     
       upstream 10x|    0.0051966     
      downstream   |    0.0051592   
     downstream 3x |    0.0051893   
     downstream 10x|    0.0051950    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 2479 at Sun Mar  4 17:37:53 EST 2001
    Right Arm D1 momentum                    : 1.433
    Right Arm arm angle                      : 24.4746
    Left Arm D1 momentum                      : 1.43299
    Left Arm arm angle                        : 24.4342
    Tiefenbach Hall A energy                : 1722.69
    Right Arm arm mispointing (HPT)          : -2.0548
    Left Arm arm mispointing (HPT)            : 3.71282
    Right Arm Q1 power supply current        : 1077.55
    Right Arm Q1 momentum                    : 1.43303
    Right Arm Q1 gauss meter                 : -0.0269
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 616.83
    Right Arm Q2 momentum                    : 1.43326
    Right Arm Q2 gauss meter                 : 0.3241
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 489.979
    Right Arm D1 momentum                    : 1.433
    Right Arm D1 NMR                         : 0.531769
    Right Arm Q3 power supply current        : 570.313
    Right Arm Q3 momentum                    : 1.43328
    Right Arm Q3 gauss meter                 : 0.2557
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 1078.04
    Left Arm Q1 momentum                      : 0
    Left Arm Q1 gauss meter                   : 0.09183
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 616.909
    Left Arm Q2 momentum                      : 1.43267
    Left Arm Q2 gauss meter                   : -0.3253
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 480.033
    Left Arm D1 momentum                      : 1.43299
    Left Arm D1 NMR                           : 0.530384
    Left Arm Q3 power supply current          : 570.524
    Left Arm Q3 momentum                      : 1.43305
    Left Arm Q3 gauss meter                   : 0.285
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 9.94075
    Current on Unser monitor                : 16.0256
    Current on Upstream bcm                 : 9.90277
    Current on Downstream bcm               : 9.97873
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 64.5575
    MBSY1c Hall A Beam energy               : 1724.44
    MBSY1c magnet current (amp)             : 71.6882
    MBSY1c Bdl                              : 430337
    MBSY3c Hall C Beam energy               : 3406.76
    Tiefenbach Hall A energy                : 1722.69
    Tiefenbach Hall C energy                : 3399.15
    Delta(E)/E width (MV_AI_DXWID)          : 7.06912
    IPM1C12.XPOS                            : 0.00240511
    IPM1H04A.XPOS                           : 1.1779
    IPM1H04A.YPOS                           : 0.689906
    IPM1H04B.XPOS                           : 0.0401944
    IPM1H04B.YPOS                           : -0.0738129
    Right Arm Arm Collimator                 : 0.615088
    Left Arm Arm Collimator                   : 0.616943
     HacR_HPM_LVDT:VALr                     : -699
     HacR_VPM_LVDT:VALr                     : 136
     HacR_HPE1313A:0_Ch58                   : -0.537598
     HacR_HPE1313A:0_Ch55                   : 22.7539
     HacR_HPE1313A:0_Ch54                   : -0.779785
     HacR_alignROLL                         : -0.298985
     HacR_alignPITCH                        : -0.018074
     HacR_alignHPT                          : -2.05504
     HacL_HPM_LVDT:VALr                     : -6739
     HacL_VPM_LVDT:VALr                     : 1493
     HacL_HPE1313A:0_Ch58                   : -0.148438
     HacL_HPE1313A:0_Ch55                   : 23.5352
     HacL_HPE1313A:0_Ch54                   : -0.179199
     HacL_alignROLL                         : 0.175495
     HacL_alignPITCH                        : -0.112073
     HacL_alignHPT                          : 3.71261
    haBDSPOS                                 : 1.72635e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 69
    haL3_Fan_frequency_R                     : 24.5
    haH2_P_Fill_Target_R                     : 24.42
    haH2_P_Exhaust_R                         : 24.82
    haH2_P_Fill_Bottle_R                     : 24.91
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -999.99
    haD2_P_Exhaust_R                         : 21.04
    haD2_P_Fill_Bottle_R                     : 43.37
    haD2_DP_Fill_Exhaust_R                   : 0.0769
    haSC200_6_Sensor_1_R                     : 241.63
    haSC200_6_Sensor_2_R                     : 25.04
    haSC200_6_Sensor_3_R                     : 37.26
    haSC200_6_Sensor_4_R                     : 40.61
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 83.05
    haITC502_1_Sensor_2_R                    : 82.21
    haITC502_1_Sensor_3_R                    : 74.97
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19
    haITC502_4_Sensor_1_R                    : 82.1
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 21.9
    haITC502_5_Sensor_1_R                    : 87.85
    haITC502_5_Sensor_2_R                    : 81.73
    haITC502_5_Sensor_3_R                    : 269.7
    haITC502_6_Sensor_1_R                    : 94.35
    haITC502_6_Sensor_2_R                    : 79.4
    haITC502_6_Sensor_3_R                    : 28.22
    Right Arm Arm Collimator                 : 0.615137
    Left Arm Arm Collimator                   : 0.616943
    Wien angle                               : 45.4996
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 1016.1
    Wien field                               : 29.657
    Laser attenuation Hall A                 : 144
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : OFF