    User name adev

    Log entry time 23:45:05 on March 4, 2001

    Entry number 57714

    keyword=End_of_Run_2503
    ****************************
     Run Number: 2503
    End of Run Comment:
    RunType=pion_prod,Tar=LD2-15cm,Rad=6,comment=5_coin,mode=coincidence,Lmom=0.9891,Rmom=-1.238,Ene=1.723,Angle_R=36.02,Angle_L=47.35
    
    
    Time of run = 17.584082 min
    Av. current (on 3x) = 17.838483 uA
    Av. current (on 1x) = 17.781708 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|   18.7605  |   18.8204  |   18.8569
    up-down    (mC)|   -0.0750  |   -0.0492  |   -0.0117
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 6130.5884 Hz  |    343672.1 /mC  |   61.306 Hz  |   6468046  |   100   |    344769.4 /mC
        2      | 50589.071 Hz  |   2835951.5 /mC  |   31.618 Hz  |  53373741  |  1600   |   2845006.3 /mC
        3      | 16767.758 Hz  |    939976.7 /mC  |  167.678 Hz  |  17690738  |   100   |    942978.0 /mC
        4      | 46889.634 Hz  |   2628566.3 /mC  |   29.306 Hz  |  49470669  |  1600   |   2636959.0 /mC
        5      | 495.6064 Hz  |     27783.0 /mC  |  495.606 Hz  |    522887  |     1   |     27871.7 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 485.42958 Hz  |     27212.5 /mC  |  485.430 Hz  | 512150.0  |     1   |     27299.4 /mC
        8    | 1024.0 Hz  |     57404.0 /mC  |    0.016 Hz  |   1080366  | 65535   |     57587.3 /mC
        output                       673.946 Hz
    Av. deadtime from accepted triggers = 0.1311
    Av. deadtime from gated scalers = 0.1368
    Accepted triggers  = 711043.00000
    Rate of Left Arm Pulser for electronic DT  = 10.176818
    Rate of Right Arm Pulser for electronic DT  = 0.0
    Rate of Left Arm Pulser&trig for electronic DT  = 10.169235
    Rate of Right Arm Pulser&trig for electronic DT  = 0.0
    Left Arm Electronic DT  = 0.00074508708
    Right Arm Electronic DT  = -1
    Rate of Left Strobe  = 100088.75
    Rate of Right Arm Strobe  = 57342.281
        Signal     |    Charge   (C)   
       upstream    |    0.0187230     
       upstream 3x |    0.0187958     
       upstream 10x|    0.0188510     
      downstream   |    0.0187980   
     downstream 3x |    0.0188450   
     downstream 10x|    0.0188627    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 2503 at Sun Mar  4 23:44:47 EST 2001
    Right Arm D1 momentum                    : 1.238
    Right Arm arm angle                      : 36.002
    Left Arm D1 momentum                      : 0.989091
    Left Arm arm angle                        : 47.3497
    Tiefenbach Hall A energy                : 1722.7
    Right Arm arm mispointing (HPT)          : 2.40604
    Left Arm arm mispointing (HPT)            : 5.97967
    Right Arm Q1 power supply current        : 930.895
    Right Arm Q1 momentum                    : 1.238
    Right Arm Q1 gauss meter                 : -0.02325
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 532.873
    Right Arm Q2 momentum                    : 1.23818
    Right Arm Q2 gauss meter                 : 0.2801
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 422.818
    Right Arm D1 momentum                    : 1.238
    Right Arm D1 NMR                         : 0.459407
    Right Arm Q3 power supply current        : 492.697
    Right Arm Q3 momentum                    : 1.23822
    Right Arm Q3 gauss meter                 : 0.2207
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 743.925
    Left Arm Q1 momentum                      : 0.988826
    Left Arm Q1 gauss meter                   : 0.06366
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 426.007
    Left Arm Q2 momentum                      : 0.989334
    Left Arm Q2 gauss meter                   : -0.2248
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 329.679
    Left Arm D1 momentum                      : 0.989091
    Left Arm D1 NMR                           : 0.366194
    Left Arm Q3 power supply current          : 393.783
    Left Arm Q3 momentum                      : 0.989109
    Left Arm Q3 gauss meter                   : 0.19746
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 0.137324
    Current on Unser monitor                : 6.7634
    Current on Upstream bcm                 : 0.15711
    Current on Downstream bcm               : 0.117538
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 0.00143682
    MBSY1c Hall A Beam energy               : 1724.44
    MBSY1c magnet current (amp)             : 71.6882
    MBSY1c Bdl                              : 430337
    MBSY3c Hall C Beam energy               : 3406.76
    Tiefenbach Hall A energy                : 1722.7
    Tiefenbach Hall C energy                : 3397.81
    Delta(E)/E width (MV_AI_DXWID)          : 7.06912
    IPM1C12.XPOS                            : 0.563418
    IPM1H04A.XPOS                           : 0
    IPM1H04A.YPOS                           : 0
    IPM1H04B.XPOS                           : 0
    IPM1H04B.YPOS                           : 0
    Right Arm Arm Collimator                 : 0.615088
    Left Arm Arm Collimator                   : 0.616992
     HacR_HPM_LVDT:VALr                     : -4668
     HacR_VPM_LVDT:VALr                     : 876
     HacR_HPE1313A:0_Ch58                   : -0.514648
     HacR_HPE1313A:0_Ch55                   : 22.8516
     HacR_HPE1313A:0_Ch54                   : -0.855469
     HacR_alignROLL                         : -0.374736
     HacR_alignPITCH                        : -0.0393736
     HacR_alignHPT                          : 2.40569
     HacL_HPM_LVDT:VALr                     : -8702
     HacL_VPM_LVDT:VALr                     : -912
     HacL_HPE1313A:0_Ch58                   : -0.29248
     HacL_HPE1313A:0_Ch55                   : 23.6816
     HacL_HPE1313A:0_Ch54                   : -0.348633
     HacL_alignROLL                         : 0.022419
     HacL_alignPITCH                        : 0.0165147
     HacL_alignHPT                          : 5.98057
    haBDSPOS                                 : 3.10127e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 25.5
    haL3_Fan_frequency_R                     : 37
    haH2_P_Fill_Target_R                     : 24.42
    haH2_P_Exhaust_R                         : 25.12
    haH2_P_Fill_Bottle_R                     : 24.95
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -999.99
    haD2_P_Exhaust_R                         : 20.9
    haD2_P_Fill_Bottle_R                     : 43.08
    haD2_DP_Fill_Exhaust_R                   : 0.0767
    haSC200_6_Sensor_1_R                     : 242.15
    haSC200_6_Sensor_2_R                     : 25.22
    haSC200_6_Sensor_3_R                     : 37.59
    haSC200_6_Sensor_4_R                     : 40.88
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 83.07
    haITC502_1_Sensor_2_R                    : 82.25
    haITC502_1_Sensor_3_R                    : 74.98
    haITC502_2_Sensor_1_R                    : 18.99
    haITC502_2_Sensor_2_R                    : 18.99
    haITC502_2_Sensor_3_R                    : 19.03
    haITC502_4_Sensor_1_R                    : 82.1
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 21.9
    haITC502_5_Sensor_1_R                    : 87.88
    haITC502_5_Sensor_2_R                    : 81.75
    haITC502_5_Sensor_3_R                    : 268.1
    haITC502_6_Sensor_1_R                    : 94.38
    haITC502_6_Sensor_2_R                    : 79.46
    haITC502_6_Sensor_3_R                    : 28.12
    Right Arm Arm Collimator                 : 0.615137
    Left Arm Arm Collimator                   : 0.616992
    Wien angle                               : 45.4996
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 1016.1
    Wien field                               : 29.657
    Laser attenuation Hall A                 : 
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : OFF