Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 23:45:05 on March 4, 2001
Entry number 57714
keyword=End_of_Run_2503
****************************
Run Number: 2503
End of Run Comment:
RunType=pion_prod,Tar=LD2-15cm,Rad=6,comment=5_coin,mode=coincidence,Lmom=0.9891,Rmom=-1.238,Ene=1.723,Angle_R=36.02,Angle_L=47.35
Time of run = 17.584082 min
Av. current (on 3x) = 17.838483 uA
Av. current (on 1x) = 17.781708 uA
| on 1x | on 3x | on 10x
Av. charge (mC)| 18.7605 | 18.8204 | 18.8569
up-down (mC)| -0.0750 | -0.0492 | -0.0117
Trigger | Rate(Hz) | Scaler/charge(3x)|Scaler/time/ps| Scaler | Prescale| Scaler/charge(1x)
1 | 6130.5884 Hz | 343672.1 /mC | 61.306 Hz | 6468046 | 100 | 344769.4 /mC
2 | 50589.071 Hz | 2835951.5 /mC | 31.618 Hz | 53373741 | 1600 | 2845006.3 /mC
3 | 16767.758 Hz | 939976.7 /mC | 167.678 Hz | 17690738 | 100 | 942978.0 /mC
4 | 46889.634 Hz | 2628566.3 /mC | 29.306 Hz | 49470669 | 1600 | 2636959.0 /mC
5 | 495.6064 Hz | 27783.0 /mC | 495.606 Hz | 522887 | 1 | 27871.7 /mC
Trigger 5 corrected for pulser:
5 (phys) | 485.42958 Hz | 27212.5 /mC | 485.430 Hz | 512150.0 | 1 | 27299.4 /mC
8 | 1024.0 Hz | 57404.0 /mC | 0.016 Hz | 1080366 | 65535 | 57587.3 /mC
output 673.946 Hz
Av. deadtime from accepted triggers = 0.1311
Av. deadtime from gated scalers = 0.1368
Accepted triggers = 711043.00000
Rate of Left Arm Pulser for electronic DT = 10.176818
Rate of Right Arm Pulser for electronic DT = 0.0
Rate of Left Arm Pulser&trig for electronic DT = 10.169235
Rate of Right Arm Pulser&trig for electronic DT = 0.0
Left Arm Electronic DT = 0.00074508708
Right Arm Electronic DT = -1
Rate of Left Strobe = 100088.75
Rate of Right Arm Strobe = 57342.281
Signal | Charge (C)
upstream | 0.0187230
upstream 3x | 0.0187958
upstream 10x| 0.0188510
downstream | 0.0187980
downstream 3x | 0.0188450
downstream 10x| 0.0188627
****************************
End-of-run EPICS data for Run Number 2503 at Sun Mar 4 23:44:47 EST 2001
Right Arm D1 momentum : 1.238
Right Arm arm angle : 36.002
Left Arm D1 momentum : 0.989091
Left Arm arm angle : 47.3497
Tiefenbach Hall A energy : 1722.7
Right Arm arm mispointing (HPT) : 2.40604
Left Arm arm mispointing (HPT) : 5.97967
Right Arm Q1 power supply current : 930.895
Right Arm Q1 momentum : 1.238
Right Arm Q1 gauss meter : -0.02325
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 532.873
Right Arm Q2 momentum : 1.23818
Right Arm Q2 gauss meter : 0.2801
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 422.818
Right Arm D1 momentum : 1.238
Right Arm D1 NMR : 0.459407
Right Arm Q3 power supply current : 492.697
Right Arm Q3 momentum : 1.23822
Right Arm Q3 gauss meter : 0.2207
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 743.925
Left Arm Q1 momentum : 0.988826
Left Arm Q1 gauss meter : 0.06366
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 426.007
Left Arm Q2 momentum : 0.989334
Left Arm Q2 gauss meter : -0.2248
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 329.679
Left Arm D1 momentum : 0.989091
Left Arm D1 NMR : 0.366194
Left Arm Q3 power supply current : 393.783
Left Arm Q3 momentum : 0.989109
Left Arm Q3 gauss meter : 0.19746
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 0.137324
Current on Unser monitor : 6.7634
Current on Upstream bcm : 0.15711
Current on Downstream bcm : 0.117538
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 0.00143682
MBSY1c Hall A Beam energy : 1724.44
MBSY1c magnet current (amp) : 71.6882
MBSY1c Bdl : 430337
MBSY3c Hall C Beam energy : 3406.76
Tiefenbach Hall A energy : 1722.7
Tiefenbach Hall C energy : 3397.81
Delta(E)/E width (MV_AI_DXWID) : 7.06912
IPM1C12.XPOS : 0.563418
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Right Arm Arm Collimator : 0.615088
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -4668
HacR_VPM_LVDT:VALr : 876
HacR_HPE1313A:0_Ch58 : -0.514648
HacR_HPE1313A:0_Ch55 : 22.8516
HacR_HPE1313A:0_Ch54 : -0.855469
HacR_alignROLL : -0.374736
HacR_alignPITCH : -0.0393736
HacR_alignHPT : 2.40569
HacL_HPM_LVDT:VALr : -8702
HacL_VPM_LVDT:VALr : -912
HacL_HPE1313A:0_Ch58 : -0.29248
HacL_HPE1313A:0_Ch55 : 23.6816
HacL_HPE1313A:0_Ch54 : -0.348633
HacL_alignROLL : 0.022419
HacL_alignPITCH : 0.0165147
HacL_alignHPT : 5.98057
haBDSPOS : 3.10127e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 25.5
haL3_Fan_frequency_R : 37
haH2_P_Fill_Target_R : 24.42
haH2_P_Exhaust_R : 25.12
haH2_P_Fill_Bottle_R : 24.95
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : -999.99
haD2_P_Exhaust_R : 20.9
haD2_P_Fill_Bottle_R : 43.08
haD2_DP_Fill_Exhaust_R : 0.0767
haSC200_6_Sensor_1_R : 242.15
haSC200_6_Sensor_2_R : 25.22
haSC200_6_Sensor_3_R : 37.59
haSC200_6_Sensor_4_R : 40.88
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 83.07
haITC502_1_Sensor_2_R : 82.25
haITC502_1_Sensor_3_R : 74.98
haITC502_2_Sensor_1_R : 18.99
haITC502_2_Sensor_2_R : 18.99
haITC502_2_Sensor_3_R : 19.03
haITC502_4_Sensor_1_R : 82.1
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 87.88
haITC502_5_Sensor_2_R : 81.75
haITC502_5_Sensor_3_R : 268.1
haITC502_6_Sensor_1_R : 94.38
haITC502_6_Sensor_2_R : 79.46
haITC502_6_Sensor_3_R : 28.12
Right Arm Arm Collimator : 0.615137
Left Arm Arm Collimator : 0.616992
Wien angle : 45.4996
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1016.1
Wien field : 29.657
Laser attenuation Hall A :
Laser power Hall A : 57
Half-wave plate (off=out) : OFF