User name adev
Log entry time 01:29:16 on March 5, 2001
Entry number 57724
keyword=Start_Run_2507_RunType=pion_prod,Tar=LH2-15cm,Rad=out,comment=6_coin,mode=coincidence,Lmom=1.276,Rmom=-1.015,Ene=1.723,Angle_R=49.71,Angle_L=37.34
Beginning-of-run EPICS data for Run Number 2507 at Mon Mar 5 01:29:04 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=100,ps2=1600,ps3=100,ps4=1600,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 763.21
Right Arm Q1 momentum : 1.01499
Right Arm Q1 gauss meter : -0.01911
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 436.775
Right Arm Q2 momentum : 1.01489
Right Arm Q2 gauss meter : 0.2296
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 346.289
Right Arm D1 momentum : 1.015
Right Arm D1 NMR : 0.376655
Right Arm Q3 power supply current : 404.007
Right Arm Q3 momentum : 1.01533
Right Arm Q3 gauss meter : 0.18098
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 960.33
Left Arm Q1 momentum : 1.27647
Left Arm Q1 gauss meter : 0.08187
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 549.962
Left Arm Q2 momentum : 1.2772
Left Arm Q2 gauss meter : -0.2899
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 426.965
Left Arm D1 momentum : 1.27661
Left Arm D1 NMR : 0.472551
Left Arm Q3 power supply current : 508.325
Left Arm Q3 momentum : 1.27682
Left Arm Q3 gauss meter : 0.2538
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 19.6013
Current on Unser monitor : 26.6567
Current on Upstream bcm : 19.6079
Current on Downstream bcm : 19.5947
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 19.5232
Beam energy : 1724.44
MBSY1c magnet current (amp) : 71.6882
Radiator 5V Linear Supply : 5.00611
Radiator Encoder : 0.14652
haBDSPOS : 4.643e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 67.5
haL3_Fan_frequency_R : 34.5
haSC200_6_Sensor_1_R : 241.73
haSC200_6_Sensor_2_R : 25.12
haSC200_6_Sensor_3_R : 37.36
haSC200_6_Sensor_4_R : 40.68
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 82.97
haITC502_1_Sensor_2_R : 82.15
haITC502_1_Sensor_3_R : 75.23
haITC502_4_Sensor_1_R : 82.1
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 87.79
haITC502_5_Sensor_2_R : 81.64
haITC502_5_Sensor_3_R : 266.5
haITC502_6_Sensor_1_R : 94.29
haITC502_6_Sensor_2_R : 79.43
haITC502_6_Sensor_3_R : 28.12
Right Arm Arm Collimator : 0.615186
Left Arm Arm Collimator : 0.616943
HacR_HPM_LVDT:VALr : -4258
HacR_VPM_LVDT:VALr : 654
HacR_HPE1313A:0_Ch58 : -0.520508
HacR_HPE1313A:0_Ch55 : 22.7051
HacR_HPE1313A:0_Ch54 : -0.8125
HacR_alignROLL : -0.332016
HacR_alignPITCH : -0.0342348
HacR_alignHPT : 1.89796
HacL_HPM_LVDT:VALr : -7029
HacL_VPM_LVDT:VALr : 452
HacL_HPE1313A:0_Ch58 : -0.18457
HacL_HPE1313A:0_Ch55 : 23.584
HacL_HPE1313A:0_Ch54 : -0.187988
HacL_alignROLL : 0.167102
HacL_alignPITCH : -0.0810734
HacL_alignHPT : 4.05449
Right Arm Angle Floor Angle : 49.5
Right Arm Angle Vernier : 5
Right Arm Scattering Angle : 49.713
Left Arm Angle Floor Angle : 37.5
Left Arm Angle Vernier : 8.5
Left Arm Scattering Angle : 37.3425
Wien angle : 45.4996
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1016.1
Wien field : 29.657
Laser attenuation Hall A : 180
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88