User name adev
Log entry time 06:05:07 on March 5, 2001
Entry number 57749
keyword=Start_Run_2518_RunType=pion_prod,Tar=LH2-15cm,Rad=6,comment=6_sing,mode=singles,Lmom=1.015,Rmom=-1.015,Ene=1.723,Angle_R=49.73,Angle_L=49.73
Beginning-of-run EPICS data for Run Number 2518 at Mon Mar 5 06:04:55 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=1000,ps3=5,ps4=1000,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 763.245
Right Arm Q1 momentum : 1.01504
Right Arm Q1 gauss meter : -0.019099
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 436.761
Right Arm Q2 momentum : 1.01486
Right Arm Q2 gauss meter : 0.2295
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 346.283
Right Arm D1 momentum : 1.015
Right Arm D1 NMR : 0.376654
Right Arm Q3 power supply current : 403.632
Right Arm Q3 momentum : 1.01497
Right Arm Q3 gauss meter : 0.18094
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 763.385
Left Arm Q1 momentum : 1.01469
Left Arm Q1 gauss meter : 0.06531
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 437.225
Left Arm Q2 momentum : 1.01539
Left Arm Q2 gauss meter : -0.2307
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 338.332
Left Arm D1 momentum : 1.01499
Left Arm D1 NMR : 0.375775
Left Arm Q3 power supply current : 404.111
Left Arm Q3 momentum : 1.01505
Left Arm Q3 gauss meter : 0.20265
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 28.4287
Current on Unser monitor : 36.0662
Current on Upstream bcm : 28.1898
Current on Downstream bcm : 28.6676
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 81.3358
Beam energy : 1724.44
MBSY1c magnet current (amp) : 71.6882
Radiator 5V Linear Supply : 5.02076
Radiator Encoder : 4.75946
haBDSPOS : 4.643e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 65.5
haL3_Fan_frequency_R : 37
haSC200_6_Sensor_1_R : 241.93
haSC200_6_Sensor_2_R : 25.1
haSC200_6_Sensor_3_R : 37.47
haSC200_6_Sensor_4_R : 40.79
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 83.17
haITC502_1_Sensor_2_R : 82.36
haITC502_1_Sensor_3_R : 75.31
haITC502_4_Sensor_1_R : 82.3
haITC502_4_Sensor_2_R : 19.1
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 87.96
haITC502_5_Sensor_2_R : 81.87
haITC502_5_Sensor_3_R : 266.6
haITC502_6_Sensor_1_R : 94.57
haITC502_6_Sensor_2_R : 79.68
haITC502_6_Sensor_3_R : 28.12
Right Arm Arm Collimator : 0
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -4269
HacR_VPM_LVDT:VALr : 732
HacR_HPE1313A:0_Ch58 : -0.511719
HacR_HPE1313A:0_Ch55 : 22.8027
HacR_HPE1313A:0_Ch54 : -0.830078
HacR_alignROLL : -0.34872
HacR_alignPITCH : -0.0419332
HacR_alignHPT : 1.91979
HacL_HPM_LVDT:VALr : -8398
HacL_VPM_LVDT:VALr : -507
HacL_HPE1313A:0_Ch58 : -0.266602
HacL_HPE1313A:0_Ch55 : 23.584
HacL_HPE1313A:0_Ch54 : -0.439941
HacL_alignROLL : -0.060326
HacL_alignPITCH : -0.00648441
HacL_alignHPT : 5.6795
Right Arm Angle Floor Angle : 49.5
Right Arm Angle Vernier : 5
Right Arm Scattering Angle : 49.7128
Left Arm Angle Floor Angle : 49.5
Left Arm Angle Vernier : 71
Left Arm Scattering Angle : 49.6917
Wien angle : 45.4996
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1016.1
Wien field : 29.657
Laser attenuation Hall A : 230
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88