• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 09:13:51 on March 5, 2001

    Entry number 57773

    keyword=End_of_Run_2528
    ****************************
     Run Number: 2528
    End of Run Comment:
    RunType=pion_prod,Tar=LD2-15cm,Rad=out,comment=old coin_6,mode=singles,Lmom=1.2620,Rmom=-1.002,Ene=1.723,Angle_R=49.965,Angle_L=37.432
    
    
    Time of run = 7.5927897 min
    Av. current (on 3x) = 19.370351 uA
    Av. current (on 1x) = 19.309767 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|    8.7969  |    8.8245  |    8.8412
    up-down    (mC)|   -0.0288  |   -0.0130  |    0.0027
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 861.02521 Hz  |     44450.7 /mC  |   86.103 Hz  |    392255  |    10   |     44590.1 /mC
        2      | 14510.323 Hz  |    749099.7 /mC  |   36.276 Hz  |   6610430  |   400   |    751449.9 /mC
        3      | 5918.2266 Hz  |    305530.2 /mC  |  591.823 Hz  |   2696151  |    10   |    306488.8 /mC
        4      | 17351.914 Hz  |    895797.6 /mC  |   43.380 Hz  |   7904966  |   400   |    898608.2 /mC
        5      | 100.31008 Hz  |      5178.5 /mC  |  100.310 Hz  |     45698  |     1   |      5194.8 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 90.133759 Hz  |      4653.2 /mC  |   90.134 Hz  | 41062.0  |     1   |      4667.8 /mC
        8    | 1024.0 Hz  |     52864.3 /mC  |    0.016 Hz  |    466501  | 65535   |     53030.2 /mC
        output                       777.229 Hz
    Av. deadtime from accepted triggers = 0.0723
    Av. deadtime from gated scalers = 0.1387
    Accepted triggers  = 354080.00000
    Rate of Left Arm Pulser for electronic DT  = 10.176321
    Rate of Right Arm Pulser for electronic DT  = 0.0
    Rate of Left Arm Pulser&trig for electronic DT  = 10.176321
    Rate of Right Arm Pulser&trig for electronic DT  = 0.0
    Left Arm Electronic DT  = 0.0
    Right Arm Electronic DT  = -1
    Rate of Left Strobe  = 36157.174
    Rate of Right Arm Strobe  = 15317.306
        Signal     |    Charge   (C)   
       upstream    |    0.0087825     
       upstream 3x |    0.0088180     
       upstream 10x|    0.0088425     
      downstream   |    0.0088113   
     downstream 3x |    0.0088310   
     downstream 10x|    0.0088398    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 2528 at Mon Mar  5 09:13:41 EST 2001
    Right Arm D1 momentum                    : 1.002
    Right Arm arm angle                      : 49.9654
    Left Arm D1 momentum                      : 1.262
    Left Arm arm angle                        : 37.4322
    Tiefenbach Hall A energy                : 1722.7
    Right Arm arm mispointing (HPT)          : 2.20142
    Left Arm arm mispointing (HPT)            : 4.09315
    Right Arm Q1 power supply current        : 753.34
    Right Arm Q1 momentum                    : 1.00187
    Right Arm Q1 gauss meter                 : -0.018868
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 431.168
    Right Arm Q2 momentum                    : 1.00238
    Right Arm Q2 gauss meter                 : 0.2267
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 341.729
    Right Arm D1 momentum                    : 1.002
    Right Arm D1 NMR                         : 0.37183
    Right Arm Q3 power supply current        : 398.53
    Right Arm Q3 momentum                    : 1.00156
    Right Arm Q3 gauss meter                 : 0.17865
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 949.27
    Left Arm Q1 momentum                      : 1.26177
    Left Arm Q1 gauss meter                   : 0.08098
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 543.375
    Left Arm Q2 momentum                      : 1.2619
    Left Arm Q2 gauss meter                   : -0.2864
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 422.042
    Left Arm D1 momentum                      : 1.262
    Left Arm D1 NMR                           : 0.467148
    Left Arm Q3 power supply current          : 502.383
    Left Arm Q3 momentum                      : 1.26189
    Left Arm Q3 gauss meter                   : 0.2508
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 19.3648
    Current on Unser monitor                : 26.2343
    Current on Upstream bcm                 : 19.3839
    Current on Downstream bcm               : 19.3457
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 72.2199
    MBSY1c Hall A Beam energy               : 1724.44
    MBSY1c magnet current (amp)             : 71.6882
    MBSY1c Bdl                              : 430337
    MBSY3c Hall C Beam energy               : 3406.76
    Tiefenbach Hall A energy                : 1722.7
    Tiefenbach Hall C energy                : 3399.04
    Delta(E)/E width (MV_AI_DXWID)          : 7.06912
    IPM1C12.XPOS                            : 0.00319073
    IPM1H04A.XPOS                           : 0.723627
    IPM1H04A.YPOS                           : 0.739641
    IPM1H04B.XPOS                           : -0.0533081
    IPM1H04B.YPOS                           : -0.0282155
    Right Arm Arm Collimator                 : 0.615137
    Left Arm Arm Collimator                   : 0.616992
     HacR_HPM_LVDT:VALr                     : -4512
     HacR_VPM_LVDT:VALr                     : 667
     HacR_HPE1313A:0_Ch58                   : -0.519531
     HacR_HPE1313A:0_Ch55                   : 22.7539
     HacR_HPE1313A:0_Ch54                   : -0.846191
     HacR_alignROLL                         : -0.36554
     HacR_alignPITCH                        : -0.0346837
     HacR_alignHPT                          : 2.20139
     HacL_HPM_LVDT:VALr                     : -7065
     HacL_VPM_LVDT:VALr                     : 464
     HacL_HPE1313A:0_Ch58                   : -0.18457
     HacL_HPE1313A:0_Ch55                   : 23.4863
     HacL_HPE1313A:0_Ch54                   : -0.189453
     HacL_alignROLL                         : 0.166146
     HacL_alignPITCH                        : -0.0801269
     HacL_alignHPT                          : 4.09294
    haBDSPOS                                 : 3.10127e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 26
    haL3_Fan_frequency_R                     : 37
    haH2_P_Fill_Target_R                     : 24.14
    haH2_P_Exhaust_R                         : 24.79
    haH2_P_Fill_Bottle_R                     : 24.64
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -999.99
    haD2_P_Exhaust_R                         : 20.59
    haD2_P_Fill_Bottle_R                     : 42.36
    haD2_DP_Fill_Exhaust_R                   : 0.0771
    haSC200_6_Sensor_1_R                     : 241.59
    haSC200_6_Sensor_2_R                     : 24.97
    haSC200_6_Sensor_3_R                     : 37.29
    haSC200_6_Sensor_4_R                     : 40.64
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 83.32
    haITC502_1_Sensor_2_R                    : 82.51
    haITC502_1_Sensor_3_R                    : 75.33
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19.03
    haITC502_4_Sensor_1_R                    : 82.2
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 22
    haITC502_5_Sensor_1_R                    : 88.12
    haITC502_5_Sensor_2_R                    : 82
    haITC502_5_Sensor_3_R                    : 267.8
    haITC502_6_Sensor_1_R                    : 94.59
    haITC502_6_Sensor_2_R                    : 79.6
    haITC502_6_Sensor_3_R                    : 28.11
    Right Arm Arm Collimator                 : 0.615137
    Left Arm Arm Collimator                   : 0.616992
    Wien angle                               : 45.4996
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 1016.1
    Wien field                               : 29.657
    Laser attenuation Hall A                 : 192
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : OFF