User name adev
Log entry time 03:57:49 on March 6, 2001
Entry number 57839
keyword=End_of_Run_2552
****************************
Run Number: 2552
End of Run Comment:
RunType=pion_prod,Tar=4He-10cm,Rad=6,comment=coin5,mode=coincidence,Lmom=0.9891,Rmom=-1.238,Ene=1.723,Angle_R=36.029,Angle_L=47.349
Time of run = 16.08081 min
Av. current (on 3x) = 38.990157 uA
Av. current (on 1x) = 38.884027 uA
| on 1x | on 3x | on 10x
Av. charge (mC)| 37.5172 | 37.6196 | 37.6662
up-down (mC)| -0.2188 | -0.0630 | -0.0238
Trigger | Rate(Hz) | Scaler/charge(3x)|Scaler/time/ps| Scaler | Prescale| Scaler/charge(1x)
1 | 7827.8393 Hz | 200764.5 /mC | 260.928 Hz | 7552680 | 30 | 201312.5 /mC
2 | 98075.811 Hz | 2515399.2 /mC | 98.076 Hz | 94628312 | 1000 | 2522264.8 /mC
3 | 57237.736 Hz | 1468004.7 /mC | 572.377 Hz | 55225751 | 100 | 1472011.5 /mC
4 | 94664.272 Hz | 2427901.8 /mC | 94.664 Hz | 91336693 | 1000 | 2434528.5 /mC
5 | 192.70898 Hz | 4942.5 /mC | 192.709 Hz | 185935 | 1 | 4956.0 /mC
Trigger 5 corrected for pulser:
5 (phys) | 182.53225 Hz | 4681.5 /mC | 182.532 Hz | 176116.0 | 1 | 4694.3 /mC
8 | 1024.0 Hz | 26263.0 /mC | 0.016 Hz | 988005 | 65535 | 26334.7 /mC
output 1040.566 Hz
Av. deadtime from accepted triggers = 0.1403
Av. deadtime from gated scalers = 0.1865
Accepted triggers = 1003989.00000
Rate of Left Arm Pulser for electronic DT = 10.176726
Rate of Right Arm Pulser for electronic DT = 0.0
Rate of Left Arm Pulser&trig for electronic DT = 10.142524
Rate of Right Arm Pulser&trig for electronic DT = 0.0
Left Arm Electronic DT = 0.003360831
Right Arm Electronic DT = -1
Rate of Left Strobe = 243526.86
Rate of Right Arm Strobe = 106299.3
Signal | Charge (C)
upstream | 0.0374078
upstream 3x | 0.0375881
upstream 10x| 0.0376543
downstream | 0.0376266
downstream 3x | 0.0376511
downstream 10x| 0.0376781
****************************
End-of-run EPICS data for Run Number 2552 at Tue Mar 6 03:57:39 EST 2001
Right Arm D1 momentum : 1.238
Right Arm arm angle : 36.0289
Left Arm D1 momentum : 0.989099
Left Arm arm angle : 47.349
Tiefenbach Hall A energy : 1722.69
Right Arm arm mispointing (HPT) : -1.3131
Left Arm arm mispointing (HPT) : 6.0825
Right Arm Q1 power supply current : 930.86
Right Arm Q1 momentum : 1.23795
Right Arm Q1 gauss meter : -0.023232
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 532.752
Right Arm Q2 momentum : 1.2379
Right Arm Q2 gauss meter : 0.2799
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 424.891
Right Arm D1 momentum : 1.238
Right Arm D1 NMR : 0.459406
Right Arm Q3 power supply current : 492.494
Right Arm Q3 momentum : 1.23771
Right Arm Q3 gauss meter : 0.2208
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 743.89
Left Arm Q1 momentum : 0.988779
Left Arm Q1 gauss meter : 0.06357
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 425.965
Left Arm Q2 momentum : 0.989237
Left Arm Q2 gauss meter : -0.2248
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 329.635
Left Arm D1 momentum : 0.989099
Left Arm D1 NMR : 0.366197
Left Arm Q3 power supply current : 393.627
Left Arm Q3 momentum : 0.988717
Left Arm Q3 gauss meter : 0.19744
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 38.983
Current on Unser monitor : 45.3008
Current on Upstream bcm : 39.0173
Current on Downstream bcm : 38.9488
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 39.3506
MBSY1c Hall A Beam energy : 1724.44
MBSY1c magnet current (amp) : 71.6882
MBSY1c Bdl : 430337
MBSY3c Hall C Beam energy : 3406.76
Tiefenbach Hall A energy : 1722.69
Tiefenbach Hall C energy : 3397.96
Delta(E)/E width (MV_AI_DXWID) : 7.06912
IPM1C12.XPOS : -0.00186926
IPM1H04A.XPOS : 1.80802
IPM1H04A.YPOS : 0.803577
IPM1H04B.XPOS : 0.0302682
IPM1H04B.YPOS : -0.0396869
Right Arm Arm Collimator : 0.615088
Left Arm Arm Collimator : 0.616943
HacR_HPM_LVDT:VALr : -1321
HacR_VPM_LVDT:VALr : 1004
HacR_HPE1313A:0_Ch58 : -0.506836
HacR_HPE1313A:0_Ch55 : 22.8027
HacR_HPE1313A:0_Ch54 : -0.900879
HacR_alignROLL : -0.4207
HacR_alignPITCH : -0.0464224
HacR_alignHPT : -1.31369
HacL_HPM_LVDT:VALr : -8792
HacL_VPM_LVDT:VALr : -896
HacL_HPE1313A:0_Ch58 : -0.289062
HacL_HPE1313A:0_Ch55 : 23.5352
HacL_HPE1313A:0_Ch54 : -0.350098
HacL_alignROLL : 0.0213975
HacL_alignPITCH : 0.0136002
HacL_alignHPT : 6.08051
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 68.5
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haH2_P_Fill_Target_R : 17.87
haH2_P_Exhaust_R : 18.69
haH2_P_Fill_Bottle_R : 18.37
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : -999.99
haD2_P_Exhaust_R : 17.03
haD2_P_Fill_Bottle_R : 35.1
haD2_DP_Fill_Exhaust_R : 0.076
haSC200_6_Sensor_1_R : 242.18
haSC200_6_Sensor_2_R : 224.8
haSC200_6_Sensor_3_R : 37.69
haSC200_6_Sensor_4_R : 40.88
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.8
haITC502_1_Sensor_3_R : 5.97
haITC502_2_Sensor_1_R : 94.98
haITC502_2_Sensor_2_R : 89.4
haITC502_2_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 6.1
haITC502_4_Sensor_2_R : 101.1
haITC502_4_Sensor_3_R : 67.6
haITC502_5_Sensor_1_R : 5.93
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 266.7
haITC502_6_Sensor_1_R : 6.37
haITC502_6_Sensor_2_R : 5.91
haITC502_6_Sensor_3_R : 28.29
Right Arm Arm Collimator : 0.615088
Left Arm Arm Collimator : 0.616992
Wien angle : 45.4996
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1016.1
Wien field : 29.657
Laser attenuation Hall A : 234
Laser power Hall A : 57
Half-wave plate (off=out) : OFF