User name adev
Log entry time 06:13:37 on March 6, 2001
Entry number 57859
keyword=End_of_Run_2562
****************************
Run Number: 2562
End of Run Comment:
RunType=pion_prod,Tar=4He-10cm,Rad=6,comment=coin4,mode=coincidence,Lmom=0.6974,Rmom=-1.433,Ene=1.723,Angle_R=24.472,Angle_L=58.283
Time of run = 16.465788 min
Av. current (on 3x) = 29.414728 uA
Av. current (on 1x) = 29.327476 uA
| on 1x | on 3x | on 10x
Av. charge (mC)| 28.9740 | 29.0602 | 29.1059
up-down (mC)| -0.1231 | -0.0254 | 0.0123
Trigger | Rate(Hz) | Scaler/charge(3x)|Scaler/time/ps| Scaler | Prescale| Scaler/charge(1x)
1 | 56859.738 Hz | 1933036.4 /mC | 71.075 Hz | 56174423 | 800 | 1938787.3 /mC
2 | 84407.056 Hz | 2869550.8 /mC | 21.102 Hz | 83389721 | 4000 | 2878088.0 /mC
3 | 109269.03 Hz | 3714772.8 /mC | 182.115 Hz | 107952040 | 600 | 3725824.5 /mC
4 | 70899.261 Hz | 2410332.0 /mC | 17.725 Hz | 70044731 | 4000 | 2417503.0 /mC
5 | 952.74923 Hz | 32390.2 /mC | 952.749 Hz | 941266 | 1 | 32486.6 /mC
Trigger 5 corrected for pulser:
5 (phys) | 942.57156 Hz | 32044.2 /mC | 942.572 Hz | 931211.0 | 1 | 32139.5 /mC
8 | 1024.0 Hz | 34812.5 /mC | 0.016 Hz | 1011658 | 65535 | 34916.1 /mC
output 1015.776 Hz
Av. deadtime from accepted triggers = 0.1821
Av. deadtime from gated scalers = 0.1927
Accepted triggers = 1003533.00000
Rate of Left Arm Pulser for electronic DT = 10.177669
Rate of Right Arm Pulser for electronic DT = 0.0
Rate of Left Arm Pulser&trig for electronic DT = 10.118961
Rate of Right Arm Pulser&trig for electronic DT = 0.0
Left Arm Electronic DT = 0.0057682745
Right Arm Electronic DT = -1
Rate of Left Strobe = 307380.91
Rate of Right Arm Strobe = 154368.68
Signal | Charge (C)
upstream | 0.0289125
upstream 3x | 0.0290475
upstream 10x| 0.0291120
downstream | 0.0290356
downstream 3x | 0.0290729
downstream 10x| 0.0290997
****************************
End-of-run EPICS data for Run Number 2562 at Tue Mar 6 06:13:25 EST 2001
Right Arm D1 momentum : 1.433
Right Arm arm angle : 24.4723
Left Arm D1 momentum : 0.697399
Left Arm arm angle : 58.2825
Tiefenbach Hall A energy : 1722.7
Right Arm arm mispointing (HPT) : -1.97649
Left Arm arm mispointing (HPT) : 5.25319
Right Arm Q1 power supply current : 1077.44
Right Arm Q1 momentum : 1.43289
Right Arm Q1 gauss meter : -0.026861
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 616.931
Right Arm Q2 momentum : 1.4335
Right Arm Q2 gauss meter : 0.3242
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 0
Right Arm D1 momentum : 1.433
Right Arm D1 NMR : 0.531769
Right Arm Q3 power supply current : 570.163
Right Arm Q3 momentum : 1.4329
Right Arm Q3 gauss meter : 0.2555
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 524.44
Left Arm Q1 momentum : 0.697086
Left Arm Q1 gauss meter : 0.04507
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 300.288
Left Arm Q2 momentum : 0.696796
Left Arm Q2 gauss meter : -0.15877
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 232.038
Left Arm D1 momentum : 0.697399
Left Arm D1 NMR : 0.258274
Left Arm Q3 power supply current : 277.663
Left Arm Q3 momentum : 0.697438
Left Arm Q3 gauss meter : 0.13951
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 29.3224
Current on Unser monitor : 35.2873
Current on Upstream bcm : 29.3614
Current on Downstream bcm : 29.2834
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 29.4851
MBSY1c Hall A Beam energy : 1724.44
MBSY1c magnet current (amp) : 71.6882
MBSY1c Bdl : 430337
MBSY3c Hall C Beam energy : 3406.76
Tiefenbach Hall A energy : 1722.7
Tiefenbach Hall C energy : 3397.96
Delta(E)/E width (MV_AI_DXWID) : 7.06912
IPM1C12.XPOS : -0.00238881
IPM1H04A.XPOS : 1.82022
IPM1H04A.YPOS : 0.8031
IPM1H04B.XPOS : 0.0507637
IPM1H04B.YPOS : -0.0558965
Right Arm Arm Collimator : 0.615088
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -754
HacR_VPM_LVDT:VALr : 420
HacR_HPE1313A:0_Ch58 : -0.533691
HacR_HPE1313A:0_Ch55 : 22.6562
HacR_HPE1313A:0_Ch54 : -0.808105
HacR_alignROLL : -0.326275
HacR_alignPITCH : -0.0219146
HacR_alignHPT : -1.9768
HacL_HPM_LVDT:VALr : -8075
HacL_VPM_LVDT:VALr : -265
HacL_HPE1313A:0_Ch58 : -0.302246
HacL_HPE1313A:0_Ch55 : 23.3887
HacL_HPE1313A:0_Ch54 : -0.349609
HacL_alignROLL : 0.0197966
HacL_alignPITCH : 0.0256717
HacL_alignHPT : 5.25473
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 67
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haH2_P_Fill_Target_R : 17.74
haH2_P_Exhaust_R : 18.54
haH2_P_Fill_Bottle_R : 18.21
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : -999.99
haD2_P_Exhaust_R : 17.04
haD2_P_Fill_Bottle_R : 35.15
haD2_DP_Fill_Exhaust_R :
haSC200_6_Sensor_1_R : 241.49
haSC200_6_Sensor_2_R : 223.7
haSC200_6_Sensor_3_R : 37.31
haSC200_6_Sensor_4_R : 40.63
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.8
haITC502_1_Sensor_3_R : 5.94
haITC502_2_Sensor_1_R : 94.98
haITC502_2_Sensor_2_R : 87.89
haITC502_2_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 6.1
haITC502_4_Sensor_2_R : 100.8
haITC502_4_Sensor_3_R : 67.6
haITC502_5_Sensor_1_R : 5.92
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 266.4
haITC502_6_Sensor_1_R : 8.5
haITC502_6_Sensor_2_R : 5.88
haITC502_6_Sensor_3_R : 28.17
Right Arm Arm Collimator : 0.615137
Left Arm Arm Collimator : 0.616943
Wien angle : 45.4996
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1016.1
Wien field : 29.657
Laser attenuation Hall A : 203
Laser power Hall A : 57
Half-wave plate (off=out) : OFF