User name adev
Log entry time 08:01:53 on March 6, 2001
Entry number 57870
keyword=Start_Run_2568_RunType=pion_prod,Tar=dum-10cm,Rad=6,comment=coin4,mode=coincidence,Lmom=0.6974,Rmom=-1.433,Ene=1.723,Angle_R=24.472,Angle_L=58.283
Beginning-of-run EPICS data for Run Number 2568 at Tue Mar 6 08:01:44 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=100,ps2=1000,ps3=200,ps4=1000,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 1077.51
Right Arm Q1 momentum : 1.43298
Right Arm Q1 gauss meter : -0.026877
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 616.766
Right Arm Q2 momentum : 1.43312
Right Arm Q2 gauss meter : 0.324
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 492.376
Right Arm D1 momentum : 1.433
Right Arm D1 NMR : 0.531768
Right Arm Q3 power supply current : 570.102
Right Arm Q3 momentum : 1.43274
Right Arm Q3 gauss meter : 0.2556
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 524.475
Left Arm Q1 momentum : 0.697133
Left Arm Q1 gauss meter : 0.04497
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 300.123
Left Arm Q2 momentum : 0.696989
Left Arm Q2 gauss meter : -0.15878
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 232.034
Left Arm D1 momentum : 0.697399
Left Arm D1 NMR : 0.258274
Left Arm Q3 power supply current : 277.762
Left Arm Q3 momentum : 0.697688
Left Arm Q3 gauss meter : 0.13951
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 29.0483
Current on Unser monitor : 33.8974
Current on Upstream bcm : 29.0902
Current on Downstream bcm : 28.917
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 29.4172
Beam energy : 1724.44
MBSY1c magnet current (amp) : 71.6882
Radiator 5V Linear Supply : 5.02076
Radiator Encoder : 4.75214
haBDSPOS : 2.1154e+06
haL1_Fan_frequency_R : 64.5
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 241.98
haSC200_6_Sensor_2_R : 222.17
haSC200_6_Sensor_3_R : 37.57
haSC200_6_Sensor_4_R : 40.84
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.8
haITC502_1_Sensor_3_R : 5.86
haITC502_4_Sensor_1_R : 6
haITC502_4_Sensor_2_R : 100.6
haITC502_4_Sensor_3_R : 66.3
haITC502_5_Sensor_1_R : 5.9
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 269.2
haITC502_6_Sensor_1_R : 8.35
haITC502_6_Sensor_2_R : 5.8
haITC502_6_Sensor_3_R : 28.21
Right Arm Arm Collimator : 0.615137
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -778
HacR_VPM_LVDT:VALr : 428
HacR_HPE1313A:0_Ch58 : -0.531738
HacR_HPE1313A:0_Ch55 : 22.7051
HacR_HPE1313A:0_Ch54 : -0.803223
HacR_alignROLL : -0.3232
HacR_alignPITCH : -0.0224966
HacR_alignHPT : -1.95169
HacL_HPM_LVDT:VALr : -8083
HacL_VPM_LVDT:VALr : -251
HacL_HPE1313A:0_Ch58 : -0.299316
HacL_HPE1313A:0_Ch55 : 23.584
HacL_HPE1313A:0_Ch54 : -0.345703
HacL_alignROLL : 0.0244208
HacL_alignPITCH : 0.02284
HacL_alignHPT : 5.25922
Right Arm Angle Floor Angle : 24.5
Right Arm Angle Vernier : -41.3
Right Arm Scattering Angle : 24.4722
Left Arm Angle Floor Angle : 58.5
Left Arm Angle Vernier : -0.5
Left Arm Scattering Angle : 58.2825
Wien angle : 45.4996
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1016.1
Wien field : 29.657
Laser attenuation Hall A : 195
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88