User name adev
Log entry time 17:37:28 on March 6, 2001
Entry number 57892
keyword=Start_Run_2573_RunType=pion_prod,Tar=4He-10cm,Rad=out,comment=coin12,mode=coincidence,Lmom=2.195,Rmom=-1.866,Ene=3.399,Angle_R=38.55,Angle_L=31.982
Beginning-of-run EPICS data for Run Number 2573 at Tue Mar 6 17:37:16 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=800,ps2=4000,ps3=600,ps4=4000,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 1403.19
Right Arm Q1 momentum : 1.8661
Right Arm Q1 gauss meter : -0.03493
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 803.004
Right Arm Q2 momentum : 1.86586
Right Arm Q2 gauss meter : 0.4219
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 646.098
Right Arm D1 momentum : 1.866
Right Arm D1 NMR : 0.69245
Right Arm Q3 power supply current : 742.512
Right Arm Q3 momentum : 1.86604
Right Arm Q3 gauss meter : 0.333
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1651.33
Left Arm Q1 momentum : 2.19496
Left Arm Q1 gauss meter : 0.14023
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 945.069
Left Arm Q2 momentum : 2.19477
Left Arm Q2 gauss meter : -0.4979
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 749.409
Left Arm D1 momentum : 2.195
Left Arm D1 NMR : 0.812184
Left Arm Q3 power supply current : 873.899
Left Arm Q3 momentum : 2.19507
Left Arm Q3 gauss meter : 0.4363
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 6.83005
Current on Unser monitor : 14.1707
Current on Upstream bcm : 6.85847
Current on Downstream bcm : 6.80164
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 6.95428
Beam energy : 3404.8
MBSY1c magnet current (amp) : 141.8
Radiator 5V Linear Supply : 5.01587
Radiator Encoder : 0.573871
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 67
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 241.58
haSC200_6_Sensor_2_R : 222.49
haSC200_6_Sensor_3_R : 37.41
haSC200_6_Sensor_4_R : 40.61
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.8
haITC502_1_Sensor_3_R : 5.88
haITC502_4_Sensor_1_R : 6
haITC502_4_Sensor_2_R : 98.9
haITC502_4_Sensor_3_R : 65.4
haITC502_5_Sensor_1_R : 5.9
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 266.4
haITC502_6_Sensor_1_R : 14.17
haITC502_6_Sensor_2_R : 5.83
haITC502_6_Sensor_3_R : 28.08
Right Arm Arm Collimator : 0.615186
Left Arm Arm Collimator : 0.616895
HacR_HPM_LVDT:VALr : -4592
HacR_VPM_LVDT:VALr : 832
HacR_HPE1313A:0_Ch58 : -0.51416
HacR_HPE1313A:0_Ch55 : 22.7051
HacR_HPE1313A:0_Ch54 : -0.88623
HacR_alignROLL : -0.406023
HacR_alignPITCH : -0.0409014
HacR_alignHPT : 2.34028
HacL_HPM_LVDT:VALr : -7065
HacL_VPM_LVDT:VALr : 707
HacL_HPE1313A:0_Ch58 : -0.168945
HacL_HPE1313A:0_Ch55 : 23.4375
HacL_HPE1313A:0_Ch54 : -0.178223
HacL_alignROLL : 0.176233
HacL_alignPITCH : -0.093588
HacL_alignHPT : 4.08698
Right Arm Angle Floor Angle : 38.5
Right Arm Angle Vernier : -22
Right Arm Scattering Angle : 38.5544
Left Arm Angle Floor Angle : 32
Left Arm Angle Vernier : 32.8
Left Arm Scattering Angle : 31.9824
Wien angle : 54.4574
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1225.6
Wien field : 35.677
Laser attenuation Hall A : 83
Laser power Hall A : 57
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88