Main INDEX
Monthly INDEX
PREV
NEXT
User name S. Strauch
Log entry time 23:57:43 on March 6,2001
Entry number 57905
keyword=Swing Shift Summary
Shift Summary
16:00 Hall in Beam Permit. Waiting for beam.
17:15 BeO Target Beam Position Check. 4 uA, no raster, rad. out, BeO position reading about x = 1 m, y = 2.5
17:20 Harp Scan
17:25 Target Change to 4He
17:35 start 4He-production runs
18:05 no beam (problems with tuning for Hall-B)
18:35 continue data taking with radiator 6%
18:40 crew chief called: bad vacuum reading next to Hall A scattering chamber. While talking to him the reading went back to normal. ELog entry: "Hall A vacuum valve fault at 1H03d"
18:45 crew chief called: burn through detector next to the Hall A scattering chamber is faulted causing FSD trip. MCC unable to mask the device. See ELog entry number 139655
21:30 crew chief called: MCC has optics problems
22:07 continue data taking with 4He, rad 6%
2573 : 4He, rad. out, 10 uA, spot size check
2574 : 4He, rad. out, 10 uA - 47 uA
2575 : 4He, rad. 6%, 48 uA - stopped because of beam problems
2576 : 4He, rad. 6%, 48 uA
2577 : 4He, rad. 6%, 48 uA