• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 03:43:52 on March 7, 2001

    Entry number 57917

    keyword=End_of_Run_2582
    ****************************
     Run Number: 2582
    End of Run Comment:
    RunType=pion_prod,Tar=4He-10cm,Rad=6,comment=coin12,mode=coincidence,Lmom=2.195,Rmom=-1.866,Ene=3.399,Angle_R=38.55,Angle_L=31.982
    
    Time of run = 0.64472657 min
    Av. current (on 3x) = 48.692477 uA
    Av. current (on 1x) = 48.565808 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|    1.8787  |    1.8836  |    1.8844
    up-down    (mC)|   -0.0112  |   -0.0026  |   -0.0016
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 1100.2339 Hz  |     22595.6 /mC  |  275.058 Hz  |     42561  |     4   |     22654.5 /mC
        2      | 84657.878 Hz  |   1738623.4 /mC  |   76.962 Hz  |   3274871  |  1100   |   1743158.0 /mC
        3      | 5756.704 Hz  |    118225.7 /mC  |  287.835 Hz  |    222690  |    20   |    118534.1 /mC
        4      | 95759.82 Hz  |   1966624.5 /mC  |   63.840 Hz  |   3704334  |  1500   |   1971753.9 /mC
        5      | 20.370393 Hz  |       418.3 /mC  |   20.370 Hz  |       788  |     1   |       419.4 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 10.211047 Hz  |       209.7 /mC  |   10.211 Hz  | 394.99998  |     1   |       210.3 /mC
        8    | 1024.0 Hz  |     21029.9 /mC  |    0.016 Hz  |     39612  | 65535   |     21084.8 /mC
        output                       657.772 Hz
    Av. deadtime from accepted triggers = 0.0838
    Av. deadtime from gated scalers = 0.1167
    Accepted triggers  =  25445.00000
    Rate of Left Arm Pulser for electronic DT  = 10.159346
    Rate of Right Arm Pulser for electronic DT  = 0.0
    Rate of Left Arm Pulser&trig for electronic DT  = 10.159346
    Rate of Right Arm Pulser&trig for electronic DT  = 0.0
    Left Arm Electronic DT  = 0.0
    Right Arm Electronic DT  = -1
    Rate of Left Strobe  = 160260.96
    Rate of Right Arm Strobe  = 83375.733
        Signal     |    Charge   (C)   
       upstream    |    0.0018731     
       upstream 3x |    0.0018823     
       upstream 10x|    0.0018836     
      downstream   |    0.0018843   
     downstream 3x |    0.0018849   
     downstream 10x|    0.0018852    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 2582 at Wed Mar  7 03:43:41 EST 2001
    Right Arm D1 momentum                    : 1.866
    Right Arm arm angle                      : 38.5542
    Left Arm D1 momentum                      : 2.195
    Left Arm arm angle                        : 31.9822
    Tiefenbach Hall A energy                : 3399.17
    Right Arm arm mispointing (HPT)          : 2.36216
    Left Arm arm mispointing (HPT)            : 4.10541
    Right Arm Q1 power supply current        : 1403.22
    Right Arm Q1 momentum                    : 1.86615
    Right Arm Q1 gauss meter                 : -0.03491
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 802.944
    Right Arm Q2 momentum                    : 1.86572
    Right Arm Q2 gauss meter                 : 0.422
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 646.092
    Right Arm D1 momentum                    : 1.866
    Right Arm D1 NMR                         : 0.69245
    Right Arm Q3 power supply current        : 742.615
    Right Arm Q3 momentum                    : 1.86629
    Right Arm Q3 gauss meter                 : 0.33308
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 1651.47
    Left Arm Q1 momentum                      : 2.19514
    Left Arm Q1 gauss meter                   : 0.14021
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 945.092
    Left Arm Q2 momentum                      : 2.19483
    Left Arm Q2 gauss meter                   : -0.4979
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 749.408
    Left Arm D1 momentum                      : 2.195
    Left Arm D1 NMR                           : 0.812183
    Left Arm Q3 power supply current          : 873.793
    Left Arm Q3 momentum                      : 2.19481
    Left Arm Q3 gauss meter                   : 0.4363
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 48.725
    Current on Unser monitor                : 54.6294
    Current on Upstream bcm                 : 48.7507
    Current on Downstream bcm               : 48.6995
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 48.9747
    MBSY1c Hall A Beam energy               : 3404.8
    MBSY1c magnet current (amp)             : 141.8
    MBSY1c Bdl                              : 849671
    MBSY3c Hall C Beam energy               : 886.375
    Tiefenbach Hall A energy                : 3399.17
    Tiefenbach Hall C energy                : 884.981
    Delta(E)/E width (MV_AI_DXWID)          : 0
    IPM1C12.XPOS                            : -0.00455144
    IPM1H04A.XPOS                           : -0.165103
    IPM1H04A.YPOS                           : 0.285397
    IPM1H04B.XPOS                           : -0.0839765
    IPM1H04B.YPOS                           : -0.0334609
    Right Arm Arm Collimator                 : 0.615137
    Left Arm Arm Collimator                   : 0.616992
     HacR_HPM_LVDT:VALr                     : -4612
     HacR_VPM_LVDT:VALr                     : 813
     HacR_HPE1313A:0_Ch58                   : -0.512207
     HacR_HPE1313A:0_Ch55                   : 22.8027
     HacR_HPE1313A:0_Ch54                   : -0.885742
     HacR_alignROLL                         : -0.405966
     HacR_alignPITCH                        : -0.042764
     HacR_alignHPT                          : 2.36244
     HacL_HPM_LVDT:VALr                     : -7080
     HacL_VPM_LVDT:VALr                     : 698
     HacL_HPE1313A:0_Ch58                   : -0.16748
     HacL_HPE1313A:0_Ch55                   : 23.6328
     HacL_HPE1313A:0_Ch54                   : -0.176758
     HacL_alignROLL                         : 0.176379
     HacL_alignPITCH                        : -0.0950449
     HacL_alignHPT                          : 4.1059
    haBDSPOS                                 : 6.517e+06
    haL1_Fan_frequency_R                     : 65.5
    haL2_Fan_frequency_R                     : 0
    haL3_Fan_frequency_R                     : 0
    haH2_P_Fill_Target_R                     : 17.31
    haH2_P_Exhaust_R                         : 18.17
    haH2_P_Fill_Bottle_R                     : 17.83
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -999.99
    haD2_P_Exhaust_R                         : 16.33
    haD2_P_Fill_Bottle_R                     : 33.72
    haD2_DP_Fill_Exhaust_R                   : 0.0761
    haSC200_6_Sensor_1_R                     : 242.05
    haSC200_6_Sensor_2_R                     : 225.26
    haSC200_6_Sensor_3_R                     : 37.84
    haSC200_6_Sensor_4_R                     : 40.81
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 5.8
    haITC502_1_Sensor_2_R                    : 5.8
    haITC502_1_Sensor_3_R                    : 5.99
    haITC502_2_Sensor_1_R                    : 94.98
    haITC502_2_Sensor_2_R                    : 90.78
    haITC502_2_Sensor_3_R                    : 94.98
    haITC502_4_Sensor_1_R                    : 6.1
    haITC502_4_Sensor_2_R                    : 99.4
    haITC502_4_Sensor_3_R                    : 64.9
    haITC502_5_Sensor_1_R                    : 5.95
    haITC502_5_Sensor_2_R                    : 5.81
    haITC502_5_Sensor_3_R                    : 266
    haITC502_6_Sensor_1_R                    : 12.34
    haITC502_6_Sensor_2_R                    : 5.94
    haITC502_6_Sensor_3_R                    : 28.17
    Right Arm Arm Collimator                 : 0.615137
    Left Arm Arm Collimator                   : 0.616895
    Wien angle                               : 54.4574
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 1225.6
    Wien field                               : 35.677
    Laser attenuation Hall A                 : 285
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : ON