User name adev
Log entry time 23:56:40 on March 7, 2001
Entry number 58000
keyword=Start_Run_2615_RunType=Optics,Tar=9foil-12C,Rad=out,comment=coin11,mode=coincidence,Lmom=1.642,Rmom=-2.363,Ene=3.399,Angle_R=27.573,Angle_L=41.696
Beginning-of-run EPICS data for Run Number 2615 at Wed Mar 7 23:56:24 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=5000,ps3=1,ps4=4500,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 1776.74
Right Arm Q1 momentum : 2.36289
Right Arm Q1 gauss meter : -0.04417
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 1017
Right Arm Q2 momentum : 2.36309
Right Arm Q2 gauss meter : 0.5342
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 829.956
Right Arm D1 momentum : 2.363
Right Arm D1 NMR : 0.876881
Right Arm Q3 power supply current : 940.467
Right Arm Q3 momentum : 2.36352
Right Arm Q3 gauss meter : 0.4218
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1235.26
Left Arm Q1 momentum : 1.6419
Left Arm Q1 gauss meter : 0.10511
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 706.826
Left Arm Q2 momentum : 1.64149
Left Arm Q2 gauss meter : -0.3727
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 551.043
Left Arm D1 momentum : 1.642
Left Arm D1 NMR : 0.607677
Left Arm Q3 power supply current : 653.779
Left Arm Q3 momentum : 1.64217
Left Arm Q3 gauss meter : 0.3265
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 29.5283
Current on Unser monitor : 36.3815
Current on Upstream bcm : 29.5059
Current on Downstream bcm : 29.5507
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 29.5632
Beam energy : 3404.8
MBSY1c magnet current (amp) : 141.8
Radiator 5V Linear Supply : 4.69841
Radiator Encoder : 0.593407
haBDSPOS : 2.50444e+06
haL1_Fan_frequency_R : 69
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 241.74
haSC200_6_Sensor_2_R : 222.62
haSC200_6_Sensor_3_R : 37.8
haSC200_6_Sensor_4_R : 40.78
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.8
haITC502_1_Sensor_3_R : 5.87
haITC502_4_Sensor_1_R : 6
haITC502_4_Sensor_2_R : 100.1
haITC502_4_Sensor_3_R : 74.8
haITC502_5_Sensor_1_R : 5.95
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 269.8
haITC502_6_Sensor_1_R : 8.7
haITC502_6_Sensor_2_R : 5.86
haITC502_6_Sensor_3_R : 28.19
Right Arm Arm Collimator : 0.615088
Left Arm Arm Collimator : 0.616943
HacR_HPM_LVDT:VALr : -718
HacR_VPM_LVDT:VALr : 177
HacR_HPE1313A:0_Ch58 : -0.547363
HacR_HPE1313A:0_Ch55 : 22.8027
HacR_HPE1313A:0_Ch54 : -0.757812
HacR_alignROLL : -0.27674
HacR_alignPITCH : -0.0091621
HacR_alignHPT : -2.04645
HacL_HPM_LVDT:VALr : -9089
HacL_VPM_LVDT:VALr : -281
HacL_HPE1313A:0_Ch58 : -0.219727
HacL_HPE1313A:0_Ch55 : 23.5352
HacL_HPE1313A:0_Ch54 : -0.249023
HacL_alignROLL : 0.112327
HacL_alignPITCH : -0.0483276
HacL_alignHPT : 6.36872
Right Arm Angle Floor Angle : 27.5
Right Arm Angle Vernier : -24
Right Arm Scattering Angle : 27.5725
Left Arm Angle Floor Angle : 42
Left Arm Angle Vernier : -14.1
Left Arm Scattering Angle : 41.6966
Wien angle : 54.4574
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1225.6
Wien field : 35.677
Laser attenuation Hall A : 208
Laser power Hall A : 57
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88