    User name adev

    Log entry time 04:14:00 on March 8, 2001

    Entry number 58022

    keyword=End_of_Run_2626
    ****************************
     Run Number: 2626
    End of Run Comment:
    RunType=pion_prod,Tar=4He-10cm,Rad=out,comment=coin10,mode=coincidence,Lmom=1.113,Rmom=-2.799,Ene=3.399,Angle_R=18.580,Angle_L=53.172
    
    Time of run = 25.137125 min
    Av. current (on 3x) = 49.342423 uA
    Av. current (on 1x) = 49.210348 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|   74.2204  |   74.4196  |   74.4364
    up-down    (mC)|   -0.4473  |   -0.1181  |   -0.0745
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 39906.465 Hz  |    808765.8 /mC  |   99.766 Hz  |  60188028  |   400   |    810936.4 /mC
        2      | 45703.56 Hz  |    926252.8 /mC  |   20.774 Hz  |  68931366  |  2200   |    928738.8 /mC
        3      | 17006.108 Hz  |    344654.9 /mC  |  100.036 Hz  |  25649080  |   170   |    345579.9 /mC
        4      | 25187.821 Hz  |    510469.9 /mC  |   20.990 Hz  |  37988964  |  1200   |    511839.9 /mC
        5      | 516.26363 Hz  |     10462.9 /mC  |  516.264 Hz  |    778643  |     1   |     10491.0 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 506.09076 Hz  |     10256.7 /mC  |  506.091 Hz  | 763300.0  |     1   |     10284.2 /mC
        8    | 1024.0 Hz  |     20752.9 /mC  |    0.016 Hz  |   1544425  | 65535   |     20808.6 /mC
        output                       663.467 Hz
    Av. deadtime from accepted triggers = 0.1195
    Av. deadtime from gated scalers = 0.1247
    Accepted triggers  = 1000659.00000
    Rate of Left Arm Pulser for electronic DT  = 10.172868
    Rate of Right Arm Pulser for electronic DT  = 0.0
    Rate of Left Arm Pulser&trig for electronic DT  = 10.166901
    Rate of Right Arm Pulser&trig for electronic DT  = 0.0
    Left Arm Electronic DT  = 0.00058658672
    Right Arm Electronic DT  = -1
    Rate of Left Strobe  = 67490.777
    Rate of Right Arm Strobe  = 93847.372
        Signal     |    Charge   (C)   
       upstream    |    0.0739968     
       upstream 3x |    0.0743605     
       upstream 10x|    0.0743992     
      downstream   |    0.0744441   
     downstream 3x |    0.0744786   
     downstream 10x|    0.0744737    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 2626 at Thu Mar  8 04:13:49 EST 2001
    Right Arm D1 momentum                    : 2.799
    Right Arm arm angle                      : 18.5799
    Left Arm D1 momentum                      : 1.113
    Left Arm arm angle                        : 53.1719
    Tiefenbach Hall A energy                : 3399.2
    Right Arm arm mispointing (HPT)          : -1.43351
    Left Arm arm mispointing (HPT)            : 5.42446
    Right Arm Q1 power supply current        : 2104.73
    Right Arm Q1 momentum                    : 2.79908
    Right Arm Q1 gauss meter                 : -0.05228
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 1204.51
    Right Arm Q2 momentum                    : 2.7988
    Right Arm Q2 gauss meter                 : 0.6324
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 997.525
    Right Arm D1 momentum                    : 2.799
    Right Arm D1 NMR                         : 1.03868
    Right Arm Q3 power supply current        : 1113.89
    Right Arm Q3 momentum                    : 2.79936
    Right Arm Q3 gauss meter                 : 0.4995
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 837.165
    Left Arm Q1 momentum                      : 1.11276
    Left Arm Q1 gauss meter                   : 0.07155
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 479.328
    Left Arm Q2 momentum                      : 1.11316
    Left Arm Q2 gauss meter                   : -0.2528
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 371.355
    Left Arm D1 momentum                      : 1.113
    Left Arm D1 NMR                           : 0.412047
    Left Arm Q3 power supply current          : 443.131
    Left Arm Q3 momentum                      : 1.11306
    Left Arm Q3 gauss meter                   : 0.2213
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 49.5292
    Current on Unser monitor                : 56.0699
    Current on Upstream bcm                 : 49.546
    Current on Downstream bcm               : 49.5123
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 49.7149
    MBSY1c Hall A Beam energy               : 3404.8
    MBSY1c magnet current (amp)             : 141.8
    MBSY1c Bdl                              : 849671
    MBSY3c Hall C Beam energy               : 886.375
    Tiefenbach Hall A energy                : 3399.2
    Tiefenbach Hall C energy                : 884.981
    Delta(E)/E width (MV_AI_DXWID)          : 2.4396
    IPM1C12.XPOS                            : 0.00932515
    IPM1H04A.XPOS                           : -0.039516
    IPM1H04A.YPOS                           : 0.515474
    IPM1H04B.XPOS                           : 0.0435547
    IPM1H04B.YPOS                           : 0.053098
    Right Arm Arm Collimator                 : 0.615088
    Left Arm Arm Collimator                   : 0.616943
     HacR_HPM_LVDT:VALr                     : -1203
     HacR_VPM_LVDT:VALr                     : 167
     HacR_HPE1313A:0_Ch58                   : -0.524414
     HacR_HPE1313A:0_Ch55                   : 22.8516
     HacR_HPE1313A:0_Ch54                   : -0.833496
     HacR_alignROLL                         : -0.353593
     HacR_alignPITCH                        : -0.030777
     HacR_alignHPT                          : -1.43323
     HacL_HPM_LVDT:VALr                     : -8188
     HacL_VPM_LVDT:VALr                     : -563
     HacL_HPE1313A:0_Ch58                   : -0.29248
     HacL_HPE1313A:0_Ch55                   : 23.6328
     HacL_HPE1313A:0_Ch54                   : -0.394043
     HacL_alignROLL                         : -0.0173403
     HacL_alignPITCH                        : 0.0156414
     HacL_alignHPT                          : 5.4231
    haBDSPOS                                 : 6.517e+06
    haL1_Fan_frequency_R                     : 69.5
    haL2_Fan_frequency_R                     : 0
    haL3_Fan_frequency_R                     : 0
    haH2_P_Fill_Target_R                     : 17.31
    haH2_P_Exhaust_R                         : 18.17
    haH2_P_Fill_Bottle_R                     : 17.83
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -999.99
    haD2_P_Exhaust_R                         : 18
    haD2_P_Fill_Bottle_R                     : 37.22
    haD2_DP_Fill_Exhaust_R                   : 0.0761
    haSC200_6_Sensor_1_R                     : 242.03
    haSC200_6_Sensor_2_R                     : 225.27
    haSC200_6_Sensor_3_R                     : 37.95
    haSC200_6_Sensor_4_R                     : 40.81
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 5.8
    haITC502_1_Sensor_2_R                    : 5.8
    haITC502_1_Sensor_3_R                    : 5.99
    haITC502_2_Sensor_1_R                    : 94.98
    haITC502_2_Sensor_2_R                    : 86.6
    haITC502_2_Sensor_3_R                    : 94.98
    haITC502_4_Sensor_1_R                    : 6.1
    haITC502_4_Sensor_2_R                    : 102.1
    haITC502_4_Sensor_3_R                    : 75.7
    haITC502_5_Sensor_1_R                    : 5.99
    haITC502_5_Sensor_2_R                    : 5.82
    haITC502_5_Sensor_3_R                    : 266
    haITC502_6_Sensor_1_R                    : 11.07
    haITC502_6_Sensor_2_R                    : 6.41
    haITC502_6_Sensor_3_R                    : 28.1
    Right Arm Arm Collimator                 : 0.615137
    Left Arm Arm Collimator                   : 0.616943
    Wien angle                               : 54.4574
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 1225.6
    Wien field                               : 35.677
    Laser attenuation Hall A                 : 275
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : ON