    User name adev

    Log entry time 06:40:39 on March 8, 2001

    Entry number 58038

    keyword=End_of_Run_2633
    ****************************
     Run Number: 2633
    End of Run Comment:
    RunType=pion_prod,Tar=dum-10cm,Rad=6,comment=coin10,mode=coincidence,Lmom=1.113,Rmom=-2.799,Ene=3.399,Angle_R=18.580,Angle_L=53.172
    
    
    Time of run = 30.801905 min
    Av. current (on 3x) = 29.6868 uA
    Av. current (on 1x) = 29.596925 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|   54.6985  |   54.8646  |   54.9440
    up-down    (mC)|   -0.2407  |   -0.0711  |    0.0141
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 5479.9203 Hz  |    184591.1 /mC  |  109.598 Hz  |  10127519  |    50   |    185151.7 /mC
        2      | 46641.398 Hz  |   1571115.7 /mC  |   23.321 Hz  |  86198635  |  2000   |   1575886.6 /mC
        3      | 6920.2143 Hz  |    233107.5 /mC  |   98.860 Hz  |  12789347  |    70   |    233815.3 /mC
        4      | 37503.63 Hz  |   1263309.9 /mC  |   18.752 Hz  |  69310994  |  2000   |   1267146.2 /mC
        5      | 23.747449 Hz  |       799.9 /mC  |   23.747 Hz  |     43888  |     1   |       802.4 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 13.570048 Hz  |       457.1 /mC  |   13.570 Hz  | 25079.0  |     1   |       458.5 /mC
        8    | 1024.0 Hz  |     34493.4 /mC  |    0.016 Hz  |   1892469  | 65535   |     34598.2 /mC
        output                       255.117 Hz
    Av. deadtime from accepted triggers = 0.0671
    Av. deadtime from gated scalers = 0.0807
    Accepted triggers  = 471486.00000
    Rate of Left Arm Pulser for electronic DT  = 10.177401
    Rate of Right Arm Pulser for electronic DT  = 0.0
    Rate of Left Arm Pulser&trig for electronic DT  = 10.175778
    Rate of Right Arm Pulser&trig for electronic DT  = 0.0
    Left Arm Electronic DT  = 0.00015949811
    Right Arm Electronic DT  = -1
    Rate of Left Strobe  = 71891.661
    Rate of Right Arm Strobe  = 50197.504
        Signal     |    Charge   (C)   
       upstream    |    0.0545781     
       upstream 3x |    0.0548291     
       upstream 10x|    0.0549511     
      downstream   |    0.0548188   
     downstream 3x |    0.0549002   
     downstream 10x|    0.0549370    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 2633 at Thu Mar  8 06:40:26 EST 2001
    Right Arm D1 momentum                    : 2.799
    Right Arm arm angle                      : 18.5799
    Left Arm D1 momentum                      : 1.113
    Left Arm arm angle                        : 53.1719
    Tiefenbach Hall A energy                : 3399.21
    Right Arm arm mispointing (HPT)          : -1.42477
    Left Arm arm mispointing (HPT)            : 5.41747
    Right Arm Q1 power supply current        : 2104.55
    Right Arm Q1 momentum                    : 2.79885
    Right Arm Q1 gauss meter                 : -0.05228
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 1204.44
    Right Arm Q2 momentum                    : 2.79864
    Right Arm Q2 gauss meter                 : 0.6324
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 997.522
    Right Arm D1 momentum                    : 2.799
    Right Arm D1 NMR                         : 1.03868
    Right Arm Q3 power supply current        : 1113.61
    Right Arm Q3 momentum                    : 2.79865
    Right Arm Q3 gauss meter                 : 0.4994
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 837.13
    Left Arm Q1 momentum                      : 1.11271
    Left Arm Q1 gauss meter                   : 0.07154
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 479.226
    Left Arm Q2 momentum                      : 1.11293
    Left Arm Q2 gauss meter                   : -0.2529
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 371.358
    Left Arm D1 momentum                      : 1.113
    Left Arm D1 NMR                           : 0.412048
    Left Arm Q3 power supply current          : 443.127
    Left Arm Q3 momentum                      : 1.11305
    Left Arm Q3 gauss meter                   : 0.2213
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 29.7136
    Current on Unser monitor                : 35.4712
    Current on Upstream bcm                 : 29.776
    Current on Downstream bcm               : 29.6512
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 30.0644
    MBSY1c Hall A Beam energy               : 3404.8
    MBSY1c magnet current (amp)             : 141.8
    MBSY1c Bdl                              : 849671
    MBSY3c Hall C Beam energy               : 886.375
    Tiefenbach Hall A energy                : 3399.22
    Tiefenbach Hall C energy                : 884.981
    Delta(E)/E width (MV_AI_DXWID)          : 
    IPM1C12.XPOS                            : -0.00227946
    IPM1H04A.XPOS                           : -0.030152
    IPM1H04A.YPOS                           : 0.543184
    IPM1H04B.XPOS                           : 0.0637741
    IPM1H04B.YPOS                           : 0.0728047
    Right Arm Arm Collimator                 : 0.615186
    Left Arm Arm Collimator                   : 0.616895
     HacR_HPM_LVDT:VALr                     : -1212
     HacR_VPM_LVDT:VALr                     : 183
     HacR_HPE1313A:0_Ch58                   : -0.525879
     HacR_HPE1313A:0_Ch55                   : 22.8027
     HacR_HPE1313A:0_Ch54                   : -0.834961
     HacR_alignROLL                         : -0.354579
     HacR_alignPITCH                        : -0.0294302
     HacR_alignHPT                          : -1.42371
     HacL_HPM_LVDT:VALr                     : -8184
     HacL_VPM_LVDT:VALr                     : -547
     HacL_HPE1313A:0_Ch58                   : -0.29248
     HacL_HPE1313A:0_Ch55                   : 23.4863
     HacL_HPE1313A:0_Ch54                   : -0.393066
     HacL_alignROLL                         : -0.0179861
     HacL_alignPITCH                        : 0.0171641
     HacL_alignHPT                          : 5.42006
    haBDSPOS                                 : 2.1154e+06
    haL1_Fan_frequency_R                     : 70
    haL2_Fan_frequency_R                     : 0
    haL3_Fan_frequency_R                     : 0
    haH2_P_Fill_Target_R                     : 17.31
    haH2_P_Exhaust_R                         : 18.17
    haH2_P_Fill_Bottle_R                     : 17.83
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -840
    haD2_P_Exhaust_R                         : 17.95
    haD2_P_Fill_Bottle_R                     : 37.13
    haD2_DP_Fill_Exhaust_R                   : 0.0764
    haSC200_6_Sensor_1_R                     : 241.51
    haSC200_6_Sensor_2_R                     : 222.55
    haSC200_6_Sensor_3_R                     : 37.66
    haSC200_6_Sensor_4_R                     : 40.63
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 5.81
    haITC502_1_Sensor_2_R                    : 5.81
    haITC502_1_Sensor_3_R                    : 5.88
    haITC502_2_Sensor_1_R                    : 94.98
    haITC502_2_Sensor_2_R                    : 91.97
    haITC502_2_Sensor_3_R                    : 94.98
    haITC502_4_Sensor_1_R                    : 6
    haITC502_4_Sensor_2_R                    : 101.7
    haITC502_4_Sensor_3_R                    : 74.2
    haITC502_5_Sensor_1_R                    : 5.97
    haITC502_5_Sensor_2_R                    : 5.82
    haITC502_5_Sensor_3_R                    : 269.3
    haITC502_6_Sensor_1_R                    : 9.9
    haITC502_6_Sensor_2_R                    : 6.6
    haITC502_6_Sensor_3_R                    : 28.18
    Right Arm Arm Collimator                 : 0.615137
    Left Arm Arm Collimator                   : 0.616943
    Wien angle                               : 54.4574
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 1225.6
    Wien field                               : 35.677
    Laser attenuation Hall A                 : 210
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : ON