    User name adev

    Log entry time 07:31:36 on March 8, 2001

    Entry number 58043

    keyword=End_of_Run_2635
    ****************************
     Run Number: 2635
    End of Run Comment:
    RunType=pion_prod,Tar=9foil-12C,Rad=out,comment=coin10,mode=coincidence,Lmom=1.113,Rmom=-2.799,Ene=3.399,Angle_R=18.580,Angle_L=53.172
    
    Time of run = 1.2313639 min
    Av. current (on 3x) = 29.647341 uA
    Av. current (on 1x) = 29.560716 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|    2.1840  |    2.1904  |    2.1938
    up-down    (mC)|   -0.0124  |   -0.0053  |   -0.0021
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 3305.0749 Hz  |    111479.6 /mC  |   55.085 Hz  |    244185  |    60   |    111806.3 /mC
        2      | 8674.5679 Hz  |    292591.8 /mC  |    4.337 Hz  |    640893  |  2000   |    293449.2 /mC
        3      | 1091.6621 Hz  |     36821.6 /mC  |   10.917 Hz  |     80654  |   100   |     36929.5 /mC
        4      | 6402.751 Hz  |    215963.8 /mC  |    3.201 Hz  |    473047  |  2000   |    216596.6 /mC
        5      | 22.360029 Hz  |       754.2 /mC  |   22.360 Hz  |      1652  |     1   |       756.4 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 12.181614 Hz  |       410.9 /mC  |   12.182 Hz  | 900.00001  |     1   |       412.1 /mC
        8    | 1024.0 Hz  |     34539.4 /mC  |    0.016 Hz  |     75655  | 65535   |     34640.6 /mC
        output                        94.123 Hz
    Av. deadtime from accepted triggers = 0.0125
    Av. deadtime from gated scalers = 0.0173
    Accepted triggers  =   6954.00000
    Rate of Left Arm Pulser for electronic DT  = 10.178415
    Rate of Right Arm Pulser for electronic DT  = 0.0
    Rate of Left Arm Pulser&trig for electronic DT  = 10.178415
    Rate of Right Arm Pulser&trig for electronic DT  = 0.0
    Left Arm Electronic DT  = 0.0
    Right Arm Electronic DT  = -1
    Rate of Left Strobe  = 11893.302
    Rate of Right Arm Strobe  = 11983.202
        Signal     |    Charge   (C)   
       upstream    |    0.0021778     
       upstream 3x |    0.0021878     
       upstream 10x|    0.0021927     
      downstream   |    0.0021902   
     downstream 3x |    0.0021931   
     downstream 10x|    0.0021948    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 2635 at Thu Mar  8 07:31:26 EST 2001
    Right Arm D1 momentum                    : 2.799
    Right Arm arm angle                      : 18.5798
    Left Arm D1 momentum                      : 1.113
    Left Arm arm angle                        : 53.172
    Tiefenbach Hall A energy                : 3399.19
    Right Arm arm mispointing (HPT)          : -1.42064
    Left Arm arm mispointing (HPT)            : 5.40906
    Right Arm Q1 power supply current        : 2104.62
    Right Arm Q1 momentum                    : 2.79894
    Right Arm Q1 gauss meter                 : -0.05229
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 1204.62
    Right Arm Q2 momentum                    : 2.79905
    Right Arm Q2 gauss meter                 : 0.6324
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 997.524
    Right Arm D1 momentum                    : 2.799
    Right Arm D1 NMR                         : 1.03867
    Right Arm Q3 power supply current        : 1113.76
    Right Arm Q3 momentum                    : 2.79903
    Right Arm Q3 gauss meter                 : 0.4995
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 837.06
    Left Arm Q1 momentum                      : 1.11262
    Left Arm Q1 gauss meter                   : 0.07152
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 479.073
    Left Arm Q2 momentum                      : 1.11257
    Left Arm Q2 gauss meter                   : -0.2528
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 371.355
    Left Arm D1 momentum                      : 1.113
    Left Arm D1 NMR                           : 0.412048
    Left Arm Q3 power supply current          : 443.003
    Left Arm Q3 momentum                      : 1.11274
    Left Arm Q3 gauss meter                   : 0.2212
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 29.5422
    Current on Unser monitor                : 35.941
    Current on Upstream bcm                 : 29.5209
    Current on Downstream bcm               : 29.5635
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 29.6963
    MBSY1c Hall A Beam energy               : 3404.8
    MBSY1c magnet current (amp)             : 141.8
    MBSY1c Bdl                              : 849671
    MBSY3c Hall C Beam energy               : 886.375
    Tiefenbach Hall A energy                : 3399.19
    Tiefenbach Hall C energy                : 884.981
    Delta(E)/E width (MV_AI_DXWID)          : 2.14099
    IPM1C12.XPOS                            : -0.00621283
    IPM1H04A.XPOS                           : 3.11363
    IPM1H04A.YPOS                           : 0.450987
    IPM1H04B.XPOS                           : 2.0037
    IPM1H04B.YPOS                           : -0.00763144
    Right Arm Arm Collimator                 : 0.615088
    Left Arm Arm Collimator                   : 0.616943
     HacR_HPM_LVDT:VALr                     : -1215
     HacR_VPM_LVDT:VALr                     : 168
     HacR_HPE1313A:0_Ch58                   : -0.524414
     HacR_HPE1313A:0_Ch55                   : 22.8027
     HacR_HPE1313A:0_Ch54                   : -0.833496
     HacR_alignROLL                         : -0.352664
     HacR_alignPITCH                        : -0.0302613
     HacR_alignHPT                          : -1.42033
     HacL_HPM_LVDT:VALr                     : -8174
     HacL_VPM_LVDT:VALr                     : -554
     HacL_HPE1313A:0_Ch58                   : -0.29248
     HacL_HPE1313A:0_Ch55                   : 23.6816
     HacL_HPE1313A:0_Ch54                   : -0.39209
     HacL_alignROLL                         : -0.0174084
     HacL_alignPITCH                        : 0.0165147
     HacL_alignHPT                          : 5.40725
    haBDSPOS                                 : 2.50444e+06
    haL1_Fan_frequency_R                     : 54
    haL2_Fan_frequency_R                     : 0
    haL3_Fan_frequency_R                     : 0
    haH2_P_Fill_Target_R                     : 17.31
    haH2_P_Exhaust_R                         : 18.17
    haH2_P_Fill_Bottle_R                     : 17.83
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -880
    haD2_P_Exhaust_R                         : 18.53
    haD2_P_Fill_Bottle_R                     : 38.33
    haD2_DP_Fill_Exhaust_R                   : 0.0761
    haSC200_6_Sensor_1_R                     : 242.01
    haSC200_6_Sensor_2_R                     : 222.29
    haSC200_6_Sensor_3_R                     : 37.94
    haSC200_6_Sensor_4_R                     : 40.86
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 5.8
    haITC502_1_Sensor_2_R                    : 5.8
    haITC502_1_Sensor_3_R                    : 5.88
    haITC502_2_Sensor_1_R                    : 94.98
    haITC502_2_Sensor_2_R                    : 94
    haITC502_2_Sensor_3_R                    : 94.98
    haITC502_4_Sensor_1_R                    : 6
    haITC502_4_Sensor_2_R                    : 101.2
    haITC502_4_Sensor_3_R                    : 76.2
    haITC502_5_Sensor_1_R                    : 5.97
    haITC502_5_Sensor_2_R                    : 5.81
    haITC502_5_Sensor_3_R                    : 270
    haITC502_6_Sensor_1_R                    : 6.68
    haITC502_6_Sensor_2_R                    : 5.86
    haITC502_6_Sensor_3_R                    : 28.08
    Right Arm Arm Collimator                 : 0.615186
    Left Arm Arm Collimator                   : 0.616943
    Wien angle                               : 54.4574
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 1225.6
    Wien field                               : 35.677
    Laser attenuation Hall A                 : 209
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : ON