    User name adev

    Log entry time 08:09:20 on March 9, 2001

    Entry number 58112

    keyword=End_of_Run_2663
    ****************************
     Run Number: 2663
    End of Run Comment:
    RunType=pion_prod,Tar=9foil-12C,Rad=out,comment=sing12,mode=singles,Lmom=1.866,Rmom=-1.866,Ene=3.399,Angle_R=38.55,Angle_L=38.54
    
    Time of run = 7.9594402 min
    Av. current (on 3x) = 29.697231 uA
    Av. current (on 1x) = 29.60761 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|   14.1396  |   14.1824  |   14.2020
    up-down    (mC)|   -0.0695  |   -0.0267  |   -0.0037
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 43.725856 Hz  |      1472.4 /mC  |   43.726 Hz  |     20882  |     1   |      1476.8 /mC
        2      | 6338.8441 Hz  |    213449.0 /mC  |    6.339 Hz  |   3027219  |  1000   |    214095.1 /mC
        3      | 188.57482 Hz  |      6349.9 /mC  |  188.575 Hz  |     90057  |     1   |      6369.1 /mC
        4      | 6155.8433 Hz  |    207286.8 /mC  |    6.156 Hz  |   2939824  |  1000   |    207914.2 /mC
        5      | 10.208004 Hz  |       343.7 /mC  |   10.208 Hz  |      4875  |     1   |       344.8 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 0.023033 Hz  |         0.8 /mC  |    0.023 Hz  | 10.999964  |     1   |         0.8 /mC
        8    | 1024.0 Hz  |     34481.3 /mC  |    0.016 Hz  |    489028  | 65535   |     34585.7 /mC
        output                       224.662 Hz
    Av. deadtime from accepted triggers = 0.0424
    Av. deadtime from gated scalers = 0.0390
    Accepted triggers  = 107291.00000
    Rate of Left Arm Pulser for electronic DT  = 10.184971
    Rate of Right Arm Pulser for electronic DT  = 0.0
    Rate of Left Arm Pulser&trig for electronic DT  = 10.184971
    Rate of Right Arm Pulser&trig for electronic DT  = 0.0
    Left Arm Electronic DT  = 0.0
    Right Arm Electronic DT  = -1
    Rate of Left Strobe  = 10191.238
    Rate of Right Arm Strobe  = 6331.0588
        Signal     |    Charge   (C)   
       upstream    |    0.0141049     
       upstream 3x |    0.0141691     
       upstream 10x|    0.0142001     
      downstream   |    0.0141744   
     downstream 3x |    0.0141958   
     downstream 10x|    0.0142038    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 2663 at Fri Mar  9 08:09:05 EST 2001
    Right Arm D1 momentum                    : 1.86601
    Right Arm arm angle                      : 38.5542
    Left Arm D1 momentum                      : 1.86601
    Left Arm arm angle                        : 38.5414
    Tiefenbach Hall A energy                : 3399.19
    Right Arm arm mispointing (HPT)          : 2.36659
    Left Arm arm mispointing (HPT)            : 4.69517
    Right Arm Q1 power supply current        : 1403.19
    Right Arm Q1 momentum                    : 1.8661
    Right Arm Q1 gauss meter                 : -0.03496
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 803.137
    Right Arm Q2 momentum                    : 1.86617
    Right Arm Q2 gauss meter                 : 0.4221
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 644.073
    Right Arm D1 momentum                    : 1.86601
    Right Arm D1 NMR                         : 0.692452
    Right Arm Q3 power supply current        : 742.688
    Right Arm Q3 momentum                    : 1.86648
    Right Arm Q3 gauss meter                 : 0.3331
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 1403.81
    Left Arm Q1 momentum                      : 1.86595
    Left Arm Q1 gauss meter                   : 0.11941
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 803.568
    Left Arm Q2 momentum                      : 1.86616
    Left Arm Q2 gauss meter                   : -0.4235
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 630.237
    Left Arm D1 momentum                      : 1.86601
    Left Arm D1 NMR                           : 0.690517
    Left Arm Q3 power supply current          : 742.932
    Left Arm Q3 momentum                      : 1.86611
    Left Arm Q3 gauss meter                   : 0.3709
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 29.5571
    Current on Unser monitor                : 35.9447
    Current on Upstream bcm                 : 29.6501
    Current on Downstream bcm               : 29.464
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 29.5837
    MBSY1c Hall A Beam energy               : 3404.8
    MBSY1c magnet current (amp)             : 141.8
    MBSY1c Bdl                              : 849671
    MBSY3c Hall C Beam energy               : 886.375
    Tiefenbach Hall A energy                : 3399.19
    Tiefenbach Hall C energy                : 884.981
    Delta(E)/E width (MV_AI_DXWID)          : 0
    IPM1C12.XPOS                            : 0.00944799
    IPM1H04A.XPOS                           : 2.60119
    IPM1H04A.YPOS                           : 0.501148
    IPM1H04B.XPOS                           : 2.0973
    IPM1H04B.YPOS                           : 0.0100676
    Right Arm Arm Collimator                 : 0.615137
    Left Arm Arm Collimator                   : 0.616943
     HacR_HPM_LVDT:VALr                     : -4616
     HacR_VPM_LVDT:VALr                     : 852
     HacR_HPE1313A:0_Ch58                   : -0.509277
     HacR_HPE1313A:0_Ch55                   : 22.7051
     HacR_HPE1313A:0_Ch54                   : -0.887695
     HacR_alignROLL                         : -0.406952
     HacR_alignPITCH                        : -0.0441107
     HacR_alignHPT                          : 2.36745
     HacL_HPM_LVDT:VALr                     : -7595
     HacL_VPM_LVDT:VALr                     : 473
     HacL_HPE1313A:0_Ch58                   : -0.17041
     HacL_HPE1313A:0_Ch55                   : 23.5352
     HacL_HPE1313A:0_Ch54                   : -0.237305
     HacL_alignROLL                         : 0.122928
     HacL_alignPITCH                        : -0.0924253
     HacL_alignHPT                          : 4.6943
    haBDSPOS                                 : 2.50444e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 27.5
    haL3_Fan_frequency_R                     : 37
    haH2_P_Fill_Target_R                     : 19.59
    haH2_P_Exhaust_R                         : 20.37
    haH2_P_Fill_Bottle_R                     : 20.08
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -999.99
    haD2_P_Exhaust_R                         : 18.03
    haD2_P_Fill_Bottle_R                     : 37.42
    haD2_DP_Fill_Exhaust_R                   : 0.0744
    haSC200_6_Sensor_1_R                     : 241.33
    haSC200_6_Sensor_2_R                     : 27.52
    haSC200_6_Sensor_3_R                     : 37.69
    haSC200_6_Sensor_4_R                     : 40.53
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 84.14
    haITC502_1_Sensor_2_R                    : 83.46
    haITC502_1_Sensor_3_R                    : 76.74
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 18.99
    haITC502_2_Sensor_3_R                    : 19.02
    haITC502_4_Sensor_1_R                    : 84.7
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 21.9
    haITC502_5_Sensor_1_R                    : 91.59
    haITC502_5_Sensor_2_R                    : 82.88
    haITC502_5_Sensor_3_R                    : 269.4
    haITC502_6_Sensor_1_R                    : 98.43
    haITC502_6_Sensor_2_R                    : 82.05
    haITC502_6_Sensor_3_R                    : 28.46
    Right Arm Arm Collimator                 : 0.615186
    Left Arm Arm Collimator                   : 0.616992
    Wien angle                               : 54.4574
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 1225.6
    Wien field                               : 35.677
    Laser attenuation Hall A                 : 212
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : ON