    User name adev

    Log entry time 09:50:16 on March 9, 2001

    Entry number 58123

    keyword=End_of_Run_2666
    ****************************
     Run Number: 2666
    End of Run Comment:
    RunType=pion_prod,Tar=LD2-15cm,Rad=out,comment=sing12,mode=singles,Lmom=1.866,Rmom=-1.866,Ene=3.399,Angle_R=38.55,Angle_L=38.54
    
    
    Time of run = 14.595866 min
    Av. current (on 3x) = 29.611239 uA
    Av. current (on 1x) = 29.522515 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|   25.8544  |   25.9321  |   25.9679
    up-down    (mC)|   -0.1365  |   -0.0579  |   -0.0159
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 259.36225 Hz  |      8758.9 /mC  |  259.362 Hz  |    227137  |     1   |      8785.2 /mC
        2      | 21997.595 Hz  |    742879.9 /mC  |   21.998 Hz  |  19264437  |  1000   |    745112.5 /mC
        3      | 971.07406 Hz  |     32794.1 /mC  |  971.074 Hz  |    850420  |     1   |     32892.7 /mC
        4      | 22316.94 Hz  |    753664.5 /mC  |   22.317 Hz  |  19544104  |  1000   |    755929.5 /mC
        5      | 10.748477 Hz  |       363.0 /mC  |   10.748 Hz  |      9413  |     1   |       364.1 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 0.570938 Hz  |        19.3 /mC  |    0.571 Hz  | 500.00037  |     1   |        19.3 /mC
        8    | 1024.0 Hz  |     34581.5 /mC  |    0.016 Hz  |    896770  | 65535   |     34685.4 /mC
        output                      1030.810 Hz
    Av. deadtime from accepted triggers = 0.1845
    Av. deadtime from gated scalers = 0.1806
    Accepted triggers  = 902734.00000
    Rate of Left Arm Pulser for electronic DT  = 10.177539
    Rate of Right Arm Pulser for electronic DT  = 0.0
    Rate of Left Arm Pulser&trig for electronic DT  = 10.177539
    Rate of Right Arm Pulser&trig for electronic DT  = 0.0
    Left Arm Electronic DT  = 0.0
    Right Arm Electronic DT  = -1
    Rate of Left Strobe  = 36966.642
    Rate of Right Arm Strobe  = 21894.289
        Signal     |    Charge   (C)   
       upstream    |    0.0257861     
       upstream 3x |    0.0259031     
       upstream 10x|    0.0259600     
      downstream   |    0.0259226   
     downstream 3x |    0.0259610   
     downstream 10x|    0.0259759    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 2666 at Fri Mar  9 09:50:02 EST 2001
    Right Arm D1 momentum                    : 1.866
    Right Arm arm angle                      : 38.554
    Left Arm D1 momentum                      : 1.86601
    Left Arm arm angle                        : 38.5413
    Tiefenbach Hall A energy                : 3399.18
    Right Arm arm mispointing (HPT)          : 2.38822
    Left Arm arm mispointing (HPT)            : 4.7022
    Right Arm Q1 power supply current        : 1403.11
    Right Arm Q1 momentum                    : 1.86601
    Right Arm Q1 gauss meter                 : -0.03496
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 802.945
    Right Arm Q2 momentum                    : 1.86572
    Right Arm Q2 gauss meter                 : 0.422
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 644.073
    Right Arm D1 momentum                    : 1.866
    Right Arm D1 NMR                         : 0.692451
    Right Arm Q3 power supply current        : 742.451
    Right Arm Q3 momentum                    : 1.86588
    Right Arm Q3 gauss meter                 : 0.333
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 1403.74
    Left Arm Q1 momentum                      : 1.86586
    Left Arm Q1 gauss meter                   : 0.11941
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 803.265
    Left Arm Q2 momentum                      : 1.86546
    Left Arm Q2 gauss meter                   : -0.4234
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 630.231
    Left Arm D1 momentum                      : 1.866
    Left Arm D1 NMR                           : 0.690516
    Left Arm Q3 power supply current          : 742.863
    Left Arm Q3 momentum                      : 1.86593
    Left Arm Q3 gauss meter                   : 0.3709
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 29.3939
    Current on Unser monitor                : 36.4729
    Current on Upstream bcm                 : 29.3685
    Current on Downstream bcm               : 29.4193
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 29.4511
    MBSY1c Hall A Beam energy               : 3404.8
    MBSY1c magnet current (amp)             : 141.8
    MBSY1c Bdl                              : 849671
    MBSY3c Hall C Beam energy               : 886.375
    Tiefenbach Hall A energy                : 3399.18
    Tiefenbach Hall C energy                : 884.981
    Delta(E)/E width (MV_AI_DXWID)          : 0
    IPM1C12.XPOS                            : 0.013063
    IPM1H04A.XPOS                           : 0.420175
    IPM1H04A.YPOS                           : 0.569498
    IPM1H04B.XPOS                           : 0.00405931
    IPM1H04B.YPOS                           : 0.0953667
    Right Arm Arm Collimator                 : 0.615137
    Left Arm Arm Collimator                   : 0.616943
     HacR_HPM_LVDT:VALr                     : -4636
     HacR_VPM_LVDT:VALr                     : 837
     HacR_HPE1313A:0_Ch58                   : -0.507812
     HacR_HPE1313A:0_Ch55                   : 22.8027
     HacR_HPE1313A:0_Ch54                   : -0.887695
     HacR_alignROLL                         : -0.407389
     HacR_alignPITCH                        : -0.0455246
     HacR_alignHPT                          : 2.38879
     HacL_HPM_LVDT:VALr                     : -7603
     HacL_VPM_LVDT:VALr                     : 478
     HacL_HPE1313A:0_Ch58                   : -0.168945
     HacL_HPE1313A:0_Ch55                   : 23.6816
     HacL_HPE1313A:0_Ch54                   : -0.232422
     HacL_alignROLL                         : 0.127047
     HacL_alignPITCH                        : -0.0943189
     HacL_alignHPT                          : 4.70238
    haBDSPOS                                 : 3.10127e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 26.5
    haL3_Fan_frequency_R                     : 37
    haH2_P_Fill_Target_R                     : 20.15
    haH2_P_Exhaust_R                         : 20.95
    haH2_P_Fill_Bottle_R                     : 20.67
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -999.99
    haD2_P_Exhaust_R                         : 18.39
    haD2_P_Fill_Bottle_R                     : 38.06
    haD2_DP_Fill_Exhaust_R                   : 0.0742
    haSC200_6_Sensor_1_R                     : 241.68
    haSC200_6_Sensor_2_R                     : 27.67
    haSC200_6_Sensor_3_R                     : 37.9
    haSC200_6_Sensor_4_R                     : 40.68
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 83.97
    haITC502_1_Sensor_2_R                    : 83.27
    haITC502_1_Sensor_3_R                    : 77.1
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19.03
    haITC502_4_Sensor_1_R                    : 84.7
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 22
    haITC502_5_Sensor_1_R                    : 91.21
    haITC502_5_Sensor_2_R                    : 82.64
    haITC502_5_Sensor_3_R                    : 267.5
    haITC502_6_Sensor_1_R                    : 98.32
    haITC502_6_Sensor_2_R                    : 82.14
    haITC502_6_Sensor_3_R                    : 28.4
    Right Arm Arm Collimator                 : 0.615137
    Left Arm Arm Collimator                   : 0.616992
    Wien angle                               : 54.4574
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 1225.6
    Wien field                               : 35.677
    Laser attenuation Hall A                 : 210
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : ON