User name adev
Log entry time 11:58:31 on March 9, 2001
Entry number 58146
keyword=Start_Run_2678_RunType=pion_prod,Tar=LD2-15cm,Rad=6,comment=sing12,mode=singles,Lmom=1.866,Rmom=-1.866,Ene=3.399,Angle_R=38.55,Angle_L=38.54
Beginning-of-run EPICS data for Run Number 2678 at Fri Mar 9 11:58:18 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=4000,ps3=1,ps4=4000,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 1403.19
Right Arm Q1 momentum : 1.8661
Right Arm Q1 gauss meter : -0.03496
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 803.198
Right Arm Q2 momentum : 1.86631
Right Arm Q2 gauss meter : 0.422
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 644.07
Right Arm D1 momentum : 1.866
Right Arm D1 NMR : 0.692452
Right Arm Q3 power supply current : 742.668
Right Arm Q3 momentum : 1.86643
Right Arm Q3 gauss meter : 0.3331
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1403.85
Left Arm Q1 momentum : 1.866
Left Arm Q1 gauss meter : 0.11942
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 803.649
Left Arm Q2 momentum : 1.86635
Left Arm Q2 gauss meter : -0.4235
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 630.238
Left Arm D1 momentum : 1.86601
Left Arm D1 NMR : 0.690517
Left Arm Q3 power supply current : 742.899
Left Arm Q3 momentum : 1.86602
Left Arm Q3 gauss meter : 0.371
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 19.8841
Current on Unser monitor : 26.5175
Current on Upstream bcm : 19.8273
Current on Downstream bcm : 19.9409
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 20.1003
Beam energy : 3404.8
MBSY1c magnet current (amp) : 141.8
Radiator 5V Linear Supply : 5.02076
Radiator Encoder : 4.74969
haBDSPOS : 3.10127e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 26
haL3_Fan_frequency_R : 37
haSC200_6_Sensor_1_R : 241.28
haSC200_6_Sensor_2_R : 27.47
haSC200_6_Sensor_3_R : 37.72
haSC200_6_Sensor_4_R : 40.53
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 83.83
haITC502_1_Sensor_2_R : 83.15
haITC502_1_Sensor_3_R : 76.26
haITC502_4_Sensor_1_R : 84.3
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 22
haITC502_5_Sensor_1_R : 91.4
haITC502_5_Sensor_2_R : 82.62
haITC502_5_Sensor_3_R : 267.3
haITC502_6_Sensor_1_R : 97.79
haITC502_6_Sensor_2_R : 81.46
haITC502_6_Sensor_3_R : 28.4
Right Arm Arm Collimator : 0.615137
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -4625
HacR_VPM_LVDT:VALr : 854
HacR_HPE1313A:0_Ch58 : -0.508789
HacR_HPE1313A:0_Ch55 : 22.7539
HacR_HPE1313A:0_Ch54 : -0.888184
HacR_alignROLL : -0.407938
HacR_alignPITCH : -0.0445597
HacR_alignHPT : 2.37689
HacL_HPM_LVDT:VALr : -7596
HacL_VPM_LVDT:VALr : 487
HacL_HPE1313A:0_Ch58 : -0.169434
HacL_HPE1313A:0_Ch55 : 23.5352
HacL_HPE1313A:0_Ch54 : -0.231445
HacL_alignROLL : 0.128599
HacL_alignPITCH : -0.0932249
HacL_alignHPT : 4.69158
Right Arm Angle Floor Angle : 38.5
Right Arm Angle Vernier : -22
Right Arm Scattering Angle : 38.5541
Left Arm Angle Floor Angle : 39
Left Arm Angle Vernier : -43
Left Arm Scattering Angle : 38.5414
Wien angle : 54.4574
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1225.6
Wien field : 35.677
Laser attenuation Hall A : 176
Laser power Hall A : 57
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88