• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 15:36:23 on March 10, 2001

    Entry number 58273

    keyword=End_of_Run_2726
    ****************************
     Run Number: 2726
    End of Run Comment:
    RunType=pion_prod,Tar=LH2-15cm,Rad=6,comment=sing12,mode=singles,Lmom=1.866,Rmom=-1.866,Ene=3.395,Angle_R=38.531,Angle_L=38.553
    
    Time of run = 11.66263 min
    Av. current (on 3x) = 19.625647 uA
    Av. current (on 1x) = 19.561911 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|   13.6886  |   13.7332  |   13.7563
    up-down    (mC)|   -0.0512  |   -0.0314  |   -0.0021
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 185.63851 Hz  |      9459.0 /mC  |  185.639 Hz  |    129902  |     1   |      9489.8 /mC
        2      | 30648.877 Hz  |   1561674.7 /mC  |   30.649 Hz  |  21446791  |  1000   |   1566762.9 /mC
        3      | 510.7853 Hz  |     26026.4 /mC  |  510.785 Hz  |    357426  |     1   |     26111.2 /mC
        4      | 31242.078 Hz  |   1591900.5 /mC  |   31.242 Hz  |  21861888  |  1000   |   1597087.2 /mC
        5      | 10.230683 Hz  |       521.3 /mC  |   10.231 Hz  |      7159  |     1   |       523.0 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 0.04716 Hz  |         2.4 /mC  |    0.047 Hz  | 33.000247  |     1   |         2.4 /mC
        8    | 1024.0 Hz  |     52176.6 /mC  |    0.016 Hz  |    716552  | 65535   |     52346.6 /mC
        output                       650.872 Hz
    Av. deadtime from accepted triggers = 0.1300
    Av. deadtime from gated scalers = 0.1260
    Accepted triggers  = 455453.00000
    Rate of Left Arm Pulser for electronic DT  = 10.183523
    Rate of Right Arm Pulser for electronic DT  = 0.0
    Rate of Left Arm Pulser&trig for electronic DT  = 10.183523
    Rate of Right Arm Pulser&trig for electronic DT  = 0.0
    Left Arm Electronic DT  = 0.0
    Right Arm Electronic DT  = -1
    Rate of Left Strobe  = 50298.358
    Rate of Right Arm Strobe  = 30079.711
        Signal     |    Charge   (C)   
       upstream    |    0.0136630     
       upstream 3x |    0.0137175     
       upstream 10x|    0.0137553     
      downstream   |    0.0137142   
     downstream 3x |    0.0137489   
     downstream 10x|    0.0137574    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 2726 at Sat Mar 10 15:36:12 EST 2001
    Right Arm D1 momentum                    : 1.866
    Right Arm arm angle                      : 38.5533
    Left Arm D1 momentum                      : 1.866
    Left Arm arm angle                        : 38.5313
    Tiefenbach Hall A energy                : 3399.18
    Right Arm arm mispointing (HPT)          : 2.58049
    Left Arm arm mispointing (HPT)            : 5.70435
    Right Arm Q1 power supply current        : 1403.08
    Right Arm Q1 momentum                    : 1.86596
    Right Arm Q1 gauss meter                 : -0.03491
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 803.094
    Right Arm Q2 momentum                    : 1.86607
    Right Arm Q2 gauss meter                 : 0.422
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 646.009
    Right Arm D1 momentum                    : 1.866
    Right Arm D1 NMR                         : 0.69245
    Right Arm Q3 power supply current        : 742.608
    Right Arm Q3 momentum                    : 1.86628
    Right Arm Q3 gauss meter                 : 0.3331
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 1403.81
    Left Arm Q1 momentum                      : 1.86595
    Left Arm Q1 gauss meter                   : 0.11934
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 803.395
    Left Arm Q2 momentum                      : 1.86576
    Left Arm Q2 gauss meter                   : -0.4234
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 630.946
    Left Arm D1 momentum                      : 1.866
    Left Arm D1 NMR                           : 0.690516
    Left Arm Q3 power supply current          : 742.839
    Left Arm Q3 momentum                      : 1.86587
    Left Arm Q3 gauss meter                   : 0.3709
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 19.7296
    Current on Unser monitor                : 26.9305
    Current on Upstream bcm                 : 19.8122
    Current on Downstream bcm               : 19.6469
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 19.8222
    MBSY1c Hall A Beam energy               : 3404.8
    MBSY1c magnet current (amp)             : 141.8
    MBSY1c Bdl                              : 849671
    MBSY3c Hall C Beam energy               : 885.574
    Tiefenbach Hall A energy                : 3399.18
    Tiefenbach Hall C energy                : 883.935
    Delta(E)/E width (MV_AI_DXWID)          : 1.1568
    IPM1C12.XPOS                            : 0.00367087
    IPM1H04A.XPOS                           : 0.429281
    IPM1H04A.YPOS                           : 0.459911
    IPM1H04B.XPOS                           : 0.00971721
    IPM1H04B.YPOS                           : -0.0142888
    Right Arm Arm Collimator                 : 0.615088
    Left Arm Arm Collimator                   : 0.616943
     HacR_HPM_LVDT:VALr                     : -4812
     HacR_VPM_LVDT:VALr                     : 835
     HacR_HPE1313A:0_Ch58                   : -0.51123
     HacR_HPE1313A:0_Ch55                   : 22.7539
     HacR_HPE1313A:0_Ch54                   : -0.881836
     HacR_alignROLL                         : -0.400543
     HacR_alignPITCH                        : -0.042764
     HacR_alignHPT                          : 2.58192
     HacL_HPM_LVDT:VALr                     : -8497
     HacL_VPM_LVDT:VALr                     : 462
     HacL_HPE1313A:0_Ch58                   : -0.17334
     HacL_HPE1313A:0_Ch55                   : 23.5352
     HacL_HPE1313A:0_Ch54                   : -0.250977
     HacL_alignROLL                         : 0.111001
     HacL_alignPITCH                        : -0.0902422
     HacL_alignHPT                          : 5.70788
    haBDSPOS                                 : 4.643e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 68.5
    haL3_Fan_frequency_R                     : 24.5
    haH2_P_Fill_Target_R                     : 20.56
    haH2_P_Exhaust_R                         : 21.09
    haH2_P_Fill_Bottle_R                     : 21.1
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -999.99
    haD2_P_Exhaust_R                         : 18.99
    haD2_P_Fill_Bottle_R                     : 39.29
    haD2_DP_Fill_Exhaust_R                   : 0.0741
    haSC200_6_Sensor_1_R                     : 241.38
    haSC200_6_Sensor_2_R                     : 27.2
    haSC200_6_Sensor_3_R                     : 37.99
    haSC200_6_Sensor_4_R                     : 40.61
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 82.76
    haITC502_1_Sensor_2_R                    : 82.07
    haITC502_1_Sensor_3_R                    : 75.27
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19.06
    haITC502_4_Sensor_1_R                    : 83.5
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 21.9
    haITC502_5_Sensor_1_R                    : 90.32
    haITC502_5_Sensor_2_R                    : 81.58
    haITC502_5_Sensor_3_R                    : 265.6
    haITC502_6_Sensor_1_R                    : 96.78
    haITC502_6_Sensor_2_R                    : 80.58
    haITC502_6_Sensor_3_R                    : 28.44
    Right Arm Arm Collimator                 : 0.615137
    Left Arm Arm Collimator                   : 0.616943
    Wien angle                               : 51.3832
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 1151.4
    Wien field                               : 33.611
    Laser attenuation Hall A                 : 162
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : ON