User name adev
Log entry time 16:40:40 on March 10, 2001
Entry number 58281
keyword=Start_Run_2729_RunType=pion_prod,Tar=LH2-15cm,Rad=6,comment=sing12,mode=singles,Lmom=1.866,Rmom=-1.866,Ene=3.395,Angle_R=38.531,Angle_L=38.553
Beginning-of-run EPICS data for Run Number 2729 at Sat Mar 10 16:40:26 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=1000,ps3=1,ps4=1000,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 1403.08
Right Arm Q1 momentum : 1.86596
Right Arm Q1 gauss meter : -0.03492
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 803.207
Right Arm Q2 momentum : 1.86633
Right Arm Q2 gauss meter : 0.422
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 646.007
Right Arm D1 momentum : 1.866
Right Arm D1 NMR : 0.69245
Right Arm Q3 power supply current : 742.703
Right Arm Q3 momentum : 1.86652
Right Arm Q3 gauss meter : 0.3331
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1403.92
Left Arm Q1 momentum : 1.86609
Left Arm Q1 gauss meter : 0.11933
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 803.634
Left Arm Q2 momentum : 1.86631
Left Arm Q2 gauss meter : -0.4235
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 630.946
Left Arm D1 momentum : 1.866
Left Arm D1 NMR : 0.690514
Left Arm Q3 power supply current : 742.934
Left Arm Q3 momentum : 1.86611
Left Arm Q3 gauss meter : 0.3709
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 28.9745
Current on Unser monitor : 34.8357
Current on Upstream bcm : 28.9834
Current on Downstream bcm : 28.9656
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 29.1778
Beam energy : 3404.8
MBSY1c magnet current (amp) : 141.8
Radiator 5V Linear Supply : 5.0232
Radiator Encoder : 4.75946
haBDSPOS : 4.643e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 65.5
haL3_Fan_frequency_R : 24.5
haSC200_6_Sensor_1_R : 241.51
haSC200_6_Sensor_2_R : 27.45
haSC200_6_Sensor_3_R : 38.07
haSC200_6_Sensor_4_R : 40.73
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 82.79
haITC502_1_Sensor_2_R : 82.09
haITC502_1_Sensor_3_R : 75.16
haITC502_4_Sensor_1_R : 83.6
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 90.26
haITC502_5_Sensor_2_R : 81.6
haITC502_5_Sensor_3_R : 265.5
haITC502_6_Sensor_1_R : 96.72
haITC502_6_Sensor_2_R : 80.52
haITC502_6_Sensor_3_R : 28.43
Right Arm Arm Collimator : 0.615137
Left Arm Arm Collimator : 0.616943
HacR_HPM_LVDT:VALr : -4825
HacR_VPM_LVDT:VALr : 849
HacR_HPE1313A:0_Ch58 : -0.51123
HacR_HPE1313A:0_Ch55 : 22.6074
HacR_HPE1313A:0_Ch54 : -0.883301
HacR_alignROLL : -0.403177
HacR_alignPITCH : -0.042114
HacR_alignHPT : 2.59618
HacL_HPM_LVDT:VALr : -8501
HacL_VPM_LVDT:VALr : 473
HacL_HPE1313A:0_Ch58 : -0.172363
HacL_HPE1313A:0_Ch55 : 23.5352
HacL_HPE1313A:0_Ch54 : -0.248047
HacL_alignROLL : 0.11321
HacL_alignPITCH : -0.0906788
HacL_alignHPT : 5.71129
Right Arm Angle Floor Angle : 38.5
Right Arm Angle Vernier : -21.9
Right Arm Scattering Angle : 38.5532
Left Arm Angle Floor Angle : 38.5
Left Arm Angle Vernier : 43.2
Left Arm Scattering Angle : 38.5313
Wien angle : 51.3832
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1151.4
Wien field : 33.611
Laser attenuation Hall A : 193
Laser power Hall A : 57
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88