• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 18:34:45 on March 11, 2001

    Entry number 58432

    keyword=End_of_Run_2795
    ****************************
     Run Number: 2795
    End of Run Comment:
    RunType=pion_prod,Tar=LH2-15cm,Rad=6,comment=sing10,mode=singles,Lmom=2.799,Rmom=-2.799,Ene=3.399,Angle_R=18.582,Angle_L=18.544
    
    
    Time of run = 11.974284 min
    Av. current (on 3x) = 10.053489 uA
    Av. current (on 1x) = 10.015769 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|    7.1959  |    7.2230  |    7.2404
    up-down    (mC)|   -0.0085  |   -0.0281  |   -0.0030
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 6943.6901 Hz  |    690674.7 /mC  | 1157.282 Hz  |   4988743  |     6   |    693275.8 /mC
        2      | 24710.47 Hz  |   2457899.9 /mC  |   14.536 Hz  |  17753411  |  1700   |   2467156.4 /mC
        3      | 2940.1898 Hz  |    292454.7 /mC  |  490.032 Hz  |   2112400  |     6   |    293556.0 /mC
        4      | 23958.386 Hz  |   2383091.7 /mC  |   14.093 Hz  |  17213071  |  1700   |   2392066.5 /mC
        5      | 11.778018 Hz  |      1171.5 /mC  |   11.778 Hz  |      8462  |     1   |      1175.9 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 1.595085 Hz  |       158.7 /mC  |    1.595 Hz  | 1146.0002  |     1   |       159.3 /mC
        8    | 1024.0 Hz  |    101855.2 /mC  |    0.016 Hz  |    735700  | 65535   |    102238.8 /mC
        output                      1401.659 Hz
    Av. deadtime from accepted triggers = 0.1676
    Av. deadtime from gated scalers = 0.2974
    Accepted triggers  = 1007032.00000
    Rate of Left Arm Pulser for electronic DT  = 10.182933
    Rate of Right Arm Pulser for electronic DT  = 0.0
    Rate of Left Arm Pulser&trig for electronic DT  = 10.181541
    Rate of Right Arm Pulser&trig for electronic DT  = 0.0
    Left Arm Electronic DT  = 0.00013668671
    Right Arm Electronic DT  = -1
    Rate of Left Strobe  = 40598.598
    Rate of Right Arm Strobe  = 30950.861
        Signal     |    Charge   (C)   
       upstream    |    0.0071916     
       upstream 3x |    0.0072090     
       upstream 10x|    0.0072389     
      downstream   |    0.0072001   
     downstream 3x |    0.0072371   
     downstream 10x|    0.0072419    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 2795 at Sun Mar 11 18:34:28 EST 2001
    Right Arm D1 momentum                    : 2.799
    Right Arm arm angle                      : 18.5823
    Left Arm D1 momentum                      : 2.79899
    Left Arm arm angle                        : 18.5438
    Tiefenbach Hall A energy                : 3399.18
    Right Arm arm mispointing (HPT)          : -1.78426
    Left Arm arm mispointing (HPT)            : 3.8187
    Right Arm Q1 power supply current        : 2104.73
    Right Arm Q1 momentum                    : 2.79908
    Right Arm Q1 gauss meter                 : -0.0523
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 1204.71
    Right Arm Q2 momentum                    : 2.79892
    Right Arm Q2 gauss meter                 : 0.6324
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 997.403
    Right Arm D1 momentum                    : 2.799
    Right Arm D1 NMR                         : 1.03867
    Right Arm Q3 power supply current        : 1113.8
    Right Arm Q3 momentum                    : 2.79913
    Right Arm Q3 gauss meter                 : 0.4995
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 2105.88
    Left Arm Q1 momentum                      : 2.79914
    Left Arm Q1 gauss meter                   : 0.17857
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 1205.15
    Left Arm Q2 momentum                      : 2.79876
    Left Arm Q2 gauss meter                   : -0.6345
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 973.828
    Left Arm D1 momentum                      : 2.79899
    Left Arm D1 NMR                           : 1.03625
    Left Arm Q3 power supply current          : 1114.44
    Left Arm Q3 momentum                      : 2.79926
    Left Arm Q3 gauss meter                   : 0.5561
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 10.0066
    Current on Unser monitor                : 17.1655
    Current on Upstream bcm                 : 10.0487
    Current on Downstream bcm               : 9.96461
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 10.1077
    MBSY1c Hall A Beam energy               : 3404.8
    MBSY1c magnet current (amp)             : 141.8
    MBSY1c Bdl                              : 849671
    MBSY3c Hall C Beam energy               : 885.574
    Tiefenbach Hall A energy                : 3399.18
    Tiefenbach Hall C energy                : 884.441
    Delta(E)/E width (MV_AI_DXWID)          : 1.1718
    IPM1C12.XPOS                            : -0.00560108
    IPM1H04A.XPOS                           : 0.404005
    IPM1H04A.YPOS                           : 0.498054
    IPM1H04B.XPOS                           : 0.00197654
    IPM1H04B.YPOS                           : 0.0106075
    Right Arm Arm Collimator                 : 0.615088
    Left Arm Arm Collimator                   : 0.616943
     HacR_HPM_LVDT:VALr                     : -911
     HacR_VPM_LVDT:VALr                     : -183
     HacR_HPE1313A:0_Ch58                   : -0.522949
     HacR_HPE1313A:0_Ch55                   : 22.9004
     HacR_HPE1313A:0_Ch54                   : -0.792969
     HacR_alignROLL                         : -0.311627
     HacR_alignPITCH                        : -0.0321906
     HacR_alignHPT                          : -1.78401
     HacL_HPM_LVDT:VALr                     : -6871
     HacL_VPM_LVDT:VALr                     : 1926
     HacL_HPE1313A:0_Ch58                   : -0.147949
     HacL_HPE1313A:0_Ch55                   : 23.6816
     HacL_HPE1313A:0_Ch54                   : -0.081543
     HacL_alignROLL                         : 0.264474
     HacL_alignPITCH                        : -0.133721
     HacL_alignHPT                          : 3.81732
    haBDSPOS                                 : 4.643e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 67.5
    haL3_Fan_frequency_R                     : 24.5
    haH2_P_Fill_Target_R                     : 19.98
    haH2_P_Exhaust_R                         : 20.42
    haH2_P_Fill_Bottle_R                     : 20.53
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -999.99
    haD2_P_Exhaust_R                         : 18.62
    haD2_P_Fill_Bottle_R                     : 38.46
    haD2_DP_Fill_Exhaust_R                   : 0.0739
    haSC200_6_Sensor_1_R                     : 241.58
    haSC200_6_Sensor_2_R                     : 27.49
    haSC200_6_Sensor_3_R                     : 38.19
    haSC200_6_Sensor_4_R                     : 40.76
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 83.42
    haITC502_1_Sensor_2_R                    : 82.71
    haITC502_1_Sensor_3_R                    : 76.62
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19.04
    haITC502_4_Sensor_1_R                    : 84.7
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 21.9
    haITC502_5_Sensor_1_R                    : 90.9
    haITC502_5_Sensor_2_R                    : 82.05
    haITC502_5_Sensor_3_R                    : 265.3
    haITC502_6_Sensor_1_R                    : 98.2
    haITC502_6_Sensor_2_R                    : 81.96
    haITC502_6_Sensor_3_R                    : 28.4
    Right Arm Arm Collimator                 : 0.615137
    Left Arm Arm Collimator                   : 0.616943
    Wien angle                               : 51.3832
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 1151.4
    Wien field                               : 33.611
    Laser attenuation Hall A                 : 121
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : ON