    User name adev

    Log entry time 00:13:39 on March 12, 2001

    Entry number 58475

    keyword=End_of_Run_2813
    ****************************
     Run Number: 2813
    End of Run Comment:
    RunType=pion_prod,Tar=LD2-15cm,Rad=5,comment=coin10,mode=coincidence,Lmom=1.1130,Rmom=-2.799,Ene=3.399,Angle_R=18.582,Angle_L=53.172
    
    Time of run = 8.5277507 min
    Av. current (on 3x) = 24.310826 uA
    Av. current (on 1x) = 24.233432 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|   12.3994  |   12.4390  |   12.4576
    up-down    (mC)|   -0.0545  |   -0.0277  |   -0.0032
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 27442.049 Hz  |   1128799.5 /mC  |   76.228 Hz  |  14041137  |   360   |   1132404.6 /mC
        2      | 68727.846 Hz  |   2827046.9 /mC  |   47.728 Hz  |  35165636  |  1440   |   2836075.6 /mC
        3      | 10017.653 Hz  |    412065.5 /mC  |  166.961 Hz  |   5125683  |    60   |    413381.5 /mC
        4      | 43421.683 Hz  |   1786104.8 /mC  |   60.308 Hz  |  22217357  |   720   |   1791809.0 /mC
        5      | 863.29721 Hz  |     35510.8 /mC  |  863.297 Hz  |    441719  |     1   |     35624.2 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 853.12063 Hz  |     35092.2 /mC  |  853.121 Hz  | 436512.0  |     1   |     35204.3 /mC
        8    | 1024.0 Hz  |     42121.2 /mC  |    0.016 Hz  |    523945  | 65535   |     42255.7 /mC
        output                       981.693 Hz
    Av. deadtime from accepted triggers = 0.1804
    Av. deadtime from gated scalers = 0.1841
    Accepted triggers  = 502298.00000
    Rate of Left Arm Pulser for electronic DT  = 10.17658
    Rate of Right Arm Pulser for electronic DT  = 0.0
    Rate of Left Arm Pulser&trig for electronic DT  = 10.172671
    Rate of Right Arm Pulser&trig for electronic DT  = 0.0
    Left Arm Electronic DT  = 0.00038409833
    Right Arm Electronic DT  = -1
    Rate of Left Strobe  = 84756.866
    Rate of Right Arm Strobe  = 99524.236
        Signal     |    Charge   (C)   
       upstream    |    0.0123721     
       upstream 3x |    0.0124252     
       upstream 10x|    0.0124560     
      downstream   |    0.0124266   
     downstream 3x |    0.0124529   
     downstream 10x|    0.0124592    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 2813 at Mon Mar 12 00:13:26 EST 2001
    Right Arm D1 momentum                    : 2.799
    Right Arm arm angle                      : 18.5811
    Left Arm D1 momentum                      : 1.113
    Left Arm arm angle                        : 53.1719
    Tiefenbach Hall A energy                : 3399.2
    Right Arm arm mispointing (HPT)          : -1.61176
    Left Arm arm mispointing (HPT)            : 5.41991
    Right Arm Q1 power supply current        : 2104.73
    Right Arm Q1 momentum                    : 2.79908
    Right Arm Q1 gauss meter                 : -0.05228
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 1204.66
    Right Arm Q2 momentum                    : 2.79915
    Right Arm Q2 gauss meter                 : 0.6324
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 997.413
    Right Arm D1 momentum                    : 2.799
    Right Arm D1 NMR                         : 1.03867
    Right Arm Q3 power supply current        : 1113.74
    Right Arm Q3 momentum                    : 2.79898
    Right Arm Q3 gauss meter                 : 0.4995
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 837.13
    Left Arm Q1 momentum                      : 1.11271
    Left Arm Q1 gauss meter                   : 0.07156
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 479.109
    Left Arm Q2 momentum                      : 1.11265
    Left Arm Q2 gauss meter                   : -0.2529
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 371.548
    Left Arm D1 momentum                      : 1.113
    Left Arm D1 NMR                           : 0.412048
    Left Arm Q3 power supply current          : 443.145
    Left Arm Q3 momentum                      : 1.1131
    Left Arm Q3 gauss meter                   : 0.2213
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 24.1777
    Current on Unser monitor                : 30.2014
    Current on Upstream bcm                 : 24.1868
    Current on Downstream bcm               : 24.1687
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 24.3894
    MBSY1c Hall A Beam energy               : 3404.8
    MBSY1c magnet current (amp)             : 141.8
    MBSY1c Bdl                              : 849671
    MBSY3c Hall C Beam energy               : 885.574
    Tiefenbach Hall A energy                : 3399.2
    Tiefenbach Hall C energy                : 884.441
    Delta(E)/E width (MV_AI_DXWID)          : 1.20314
    IPM1C12.XPOS                            : -0.0132853
    IPM1H04A.XPOS                           : -0.132497
    IPM1H04A.YPOS                           : 0.480965
    IPM1H04B.XPOS                           : -0.00971369
    IPM1H04B.YPOS                           : -0.0216499
    Right Arm Arm Collimator                 : 0.615137
    Left Arm Arm Collimator                   : 0.616943
     HacR_HPM_LVDT:VALr                     : -1048
     HacR_VPM_LVDT:VALr                     : 122
     HacR_HPE1313A:0_Ch58                   : -0.521973
     HacR_HPE1313A:0_Ch55                   : 22.8516
     HacR_HPE1313A:0_Ch54                   : -0.825684
     HacR_alignROLL                         : -0.344718
     HacR_alignPITCH                        : -0.0325727
     HacR_alignHPT                          : -1.61179
     HacL_HPM_LVDT:VALr                     : -8187
     HacL_VPM_LVDT:VALr                     : -580
     HacL_HPE1313A:0_Ch58                   : -0.296387
     HacL_HPE1313A:0_Ch55                   : 23.584
     HacL_HPE1313A:0_Ch54                   : -0.390137
     HacL_alignROLL                         : -0.0152676
     HacL_alignPITCH                        : 0.0201495
     HacL_alignHPT                          : 5.42211
    haBDSPOS                                 : 3.10127e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 26.5
    haL3_Fan_frequency_R                     : 37
    haH2_P_Fill_Target_R                     : 19.52
    haH2_P_Exhaust_R                         : 20.29
    haH2_P_Fill_Bottle_R                     : 20.06
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -680
    haD2_P_Exhaust_R                         : 17.98
    haD2_P_Fill_Bottle_R                     : 37.22
    haD2_DP_Fill_Exhaust_R                   : 0.0744
    haSC200_6_Sensor_1_R                     : 241.46
    haSC200_6_Sensor_2_R                     : 27.4
    haSC200_6_Sensor_3_R                     : 38.19
    haSC200_6_Sensor_4_R                     : 40.78
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 83.81
    haITC502_1_Sensor_2_R                    : 83.11
    haITC502_1_Sensor_3_R                    : 77.11
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19.04
    haITC502_4_Sensor_1_R                    : 84.7
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 22
    haITC502_5_Sensor_1_R                    : 91.22
    haITC502_5_Sensor_2_R                    : 82.49
    haITC502_5_Sensor_3_R                    : 266.7
    haITC502_6_Sensor_1_R                    : 98.4
    haITC502_6_Sensor_2_R                    : 82.11
    haITC502_6_Sensor_3_R                    : 28.35
    Right Arm Arm Collimator                 : 0.615137
    Left Arm Arm Collimator                   : 0.616895
    Wien angle                               : 51.3832
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 1151.4
    Wien field                               : 33.611
    Laser attenuation Hall A                 : 185
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : ON