    User name adev

    Log entry time 02:42:35 on March 12, 2001

    Entry number 58499

    keyword=End_of_Run_2825
    ****************************
     Run Number: 2825
    End of Run Comment:
    RunType=pion_prod,Tar=LH2-15cm,Rad=6,comment=coin10,mode=coincidence,Lmom=1.1130,Rmom=-2.799,Ene=3.399,Angle_R=18.582,Angle_L=53.172
    
    Time of run = 10.196012 min
    Av. current (on 3x) = 14.743999 uA
    Av. current (on 1x) = 14.692836 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|    8.9885  |    9.0198  |    9.0372
    up-down    (mC)|   -0.0231  |   -0.0244  |   -0.0003
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 10189.037 Hz  |    691063.3 /mC  |   50.945 Hz  |   6233253  |   200   |    693469.8 /mC
        2      | 34351.139 Hz  |   2329838.6 /mC  |   17.176 Hz  |  21014678  |  2000   |   2337951.6 /mC
        3      | 3078.478 Hz  |    208795.3 /mC  |  102.616 Hz  |   1883292  |    30   |    209522.4 /mC
        4      | 21145.196 Hz  |   1434156.1 /mC  |   21.145 Hz  |  12935801  |  1000   |   1439150.1 /mC
        5      | 1111.7042 Hz  |     75400.5 /mC  | 1111.704 Hz  |    680097  |     1   |     75663.0 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 1101.5172 Hz  |     74709.5 /mC  | 1101.517 Hz  | 673865.0  |     1   |     74969.7 /mC
        8    | 1024.0 Hz  |     69452.0 /mC  |    0.016 Hz  |    626443  | 65535   |     69693.8 /mC
        output                      1019.399 Hz
    Av. deadtime from accepted triggers = 0.1916
    Av. deadtime from gated scalers = 0.1922
    Accepted triggers  = 623628.00000
    Rate of Left Arm Pulser for electronic DT  = 10.186989
    Rate of Right Arm Pulser for electronic DT  = 0.0
    Rate of Left Arm Pulser&trig for electronic DT  = 10.186989
    Rate of Right Arm Pulser&trig for electronic DT  = 0.0
    Left Arm Electronic DT  = 0.0
    Right Arm Electronic DT  = -1
    Rate of Left Strobe  = 38566.296
    Rate of Right Arm Strobe  = 43784.402
        Signal     |    Charge   (C)   
       upstream    |    0.0089769     
       upstream 3x |    0.0090076     
       upstream 10x|    0.0090370     
      downstream   |    0.0090000   
     downstream 3x |    0.0090320   
     downstream 10x|    0.0090373    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 2825 at Mon Mar 12 02:42:21 EST 2001
    Right Arm D1 momentum                    : 2.799
    Right Arm arm angle                      : 18.5811
    Left Arm D1 momentum                      : 1.113
    Left Arm arm angle                        : 53.1719
    Tiefenbach Hall A energy                : 3399.16
    Right Arm arm mispointing (HPT)          : -1.61151
    Left Arm arm mispointing (HPT)            : 5.41301
    Right Arm Q1 power supply current        : 2104.62
    Right Arm Q1 momentum                    : 2.79894
    Right Arm Q1 gauss meter                 : -0.05228
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 1204.53
    Right Arm Q2 momentum                    : 2.79884
    Right Arm Q2 gauss meter                 : 0.6324
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 997.403
    Right Arm D1 momentum                    : 2.799
    Right Arm D1 NMR                         : 1.03868
    Right Arm Q3 power supply current        : 1113.57
    Right Arm Q3 momentum                    : 2.79855
    Right Arm Q3 gauss meter                 : 0.4994
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 837.165
    Left Arm Q1 momentum                      : 1.11276
    Left Arm Q1 gauss meter                   : 0.07158
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 479.32
    Left Arm Q2 momentum                      : 1.11314
    Left Arm Q2 gauss meter                   : -0.2529
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 371.55
    Left Arm D1 momentum                      : 1.11301
    Left Arm D1 NMR                           : 0.412048
    Left Arm Q3 power supply current          : 443.155
    Left Arm Q3 momentum                      : 1.11312
    Left Arm Q3 gauss meter                   : 0.2212
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 14.7908
    Current on Unser monitor                : 22.2204
    Current on Upstream bcm                 : 14.7972
    Current on Downstream bcm               : 14.7845
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 14.9848
    MBSY1c Hall A Beam energy               : 3404.8
    MBSY1c magnet current (amp)             : 141.8
    MBSY1c Bdl                              : 849671
    MBSY3c Hall C Beam energy               : 885.574
    Tiefenbach Hall A energy                : 3399.16
    Tiefenbach Hall C energy                : 884.441
    Delta(E)/E width (MV_AI_DXWID)          : 1.18836
    IPM1C12.XPOS                            : -0.0075466
    IPM1H04A.XPOS                           : -0.127522
    IPM1H04A.YPOS                           : 0.488096
    IPM1H04B.XPOS                           : 0.00678352
    IPM1H04B.YPOS                           : -0.0114356
    Right Arm Arm Collimator                 : 0.615088
    Left Arm Arm Collimator                   : 0.616943
     HacR_HPM_LVDT:VALr                     : -1048
     HacR_VPM_LVDT:VALr                     : 139
     HacR_HPE1313A:0_Ch58                   : -0.522461
     HacR_HPE1313A:0_Ch55                   : 22.8027
     HacR_HPE1313A:0_Ch54                   : -0.825195
     HacR_alignROLL                         : -0.345762
     HacR_alignPITCH                        : -0.032057
     HacR_alignHPT                          : -1.61232
     HacL_HPM_LVDT:VALr                     : -8181
     HacL_VPM_LVDT:VALr                     : -553
     HacL_HPE1313A:0_Ch58                   : -0.292969
     HacL_HPE1313A:0_Ch55                   : 23.5352
     HacL_HPE1313A:0_Ch54                   : -0.387207
     HacL_alignROLL                         : -0.0126852
     HacL_alignPITCH                        : 0.0176007
     HacL_alignHPT                          : 5.41193
    haBDSPOS                                 : 4.643e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 66
    haL3_Fan_frequency_R                     : 37
    haH2_P_Fill_Target_R                     : 19.49
    haH2_P_Exhaust_R                         : 19.97
    haH2_P_Fill_Bottle_R                     : 20.04
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -640
    haD2_P_Exhaust_R                         : 17.99
    haD2_P_Fill_Bottle_R                     : 37.26
    haD2_DP_Fill_Exhaust_R                   : 0.0744
    haSC200_6_Sensor_1_R                     : 241.33
    haSC200_6_Sensor_2_R                     : 27.32
    haSC200_6_Sensor_3_R                     : 38.14
    haSC200_6_Sensor_4_R                     : 40.73
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 83.91
    haITC502_1_Sensor_2_R                    : 83.23
    haITC502_1_Sensor_3_R                    : 76.79
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 18.99
    haITC502_2_Sensor_3_R                    : 19.05
    haITC502_4_Sensor_1_R                    : 84.7
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 21.9
    haITC502_5_Sensor_1_R                    : 91.23
    haITC502_5_Sensor_2_R                    : 82.65
    haITC502_5_Sensor_3_R                    : 265.3
    haITC502_6_Sensor_1_R                    : 98.53
    haITC502_6_Sensor_2_R                    : 82.05
    haITC502_6_Sensor_3_R                    : 28.44
    Right Arm Arm Collimator                 : 0.615137
    Left Arm Arm Collimator                   : 0.616943
    Wien angle                               : 51.3832
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 1151.4
    Wien field                               : 33.611
    Laser attenuation Hall A                 : 149
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : ON