    User name adev

    Log entry time 03:12:28 on March 12, 2001

    Entry number 58502

    keyword=End_of_Run_2827
    ****************************
     Run Number: 2827
    End of Run Comment:
    RunType=pion_prod,Tar=LH2-15cm,Rad=out,comment=coin10,mode=coincidence,Lmom=1.1130,Rmom=-2.799,Ene=3.399,Angle_R=18.582,Angle_L=53.172
    
    Time of run = 14.669189 min
    Av. current (on 3x) = 14.692927 uA
    Av. current (on 1x) = 14.641913 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|   12.8871  |   12.9320  |   12.9569
    up-down    (mC)|   -0.0329  |   -0.0354  |   -0.0006
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 11422.49 Hz  |    777414.2 /mC  |   57.112 Hz  |  10053520  |   200   |    780122.8 /mC
        2      | 13277.646 Hz  |    903676.0 /mC  |    6.639 Hz  |  11686338  |  2000   |    906824.5 /mC
        3      | 2209.1723 Hz  |    150356.2 /mC  |   73.639 Hz  |   1944406  |    30   |    150880.0 /mC
        4      | 6303.0578 Hz  |    428985.8 /mC  |    6.303 Hz  |   5547645  |  1000   |    430480.5 /mC
        5      | 1360.8239 Hz  |     92617.6 /mC  | 1360.824 Hz  |   1197731  |     1   |     92940.3 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 1350.6427 Hz  |     91924.7 /mC  | 1350.643 Hz  | 1188770.0  |     1   |     92245.0 /mC
        8    | 1024.0 Hz  |     69693.4 /mC  |    0.016 Hz  |    901275  | 65535   |     69936.2 /mC
        output                      1139.995 Hz
    Av. deadtime from accepted triggers = 0.2151
    Av. deadtime from gated scalers = 0.2150
    Accepted triggers  = 1003368.00000
    Rate of Left Arm Pulser for electronic DT  = 10.181203
    Rate of Right Arm Pulser for electronic DT  = 0.0
    Rate of Left Arm Pulser&trig for electronic DT  = 10.181203
    Rate of Right Arm Pulser&trig for electronic DT  = 0.0
    Left Arm Electronic DT  = 0.0
    Right Arm Electronic DT  = -1
    Rate of Left Strobe  = 13510.368
    Rate of Right Arm Strobe  = 26744.773
        Signal     |    Charge   (C)   
       upstream    |    0.0128706     
       upstream 3x |    0.0129143     
       upstream 10x|    0.0129566     
      downstream   |    0.0129035   
     downstream 3x |    0.0129497   
     downstream 10x|    0.0129572    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 2827 at Mon Mar 12 03:12:16 EST 2001
    Right Arm D1 momentum                    : 2.799
    Right Arm arm angle                      : 18.5811
    Left Arm D1 momentum                      : 1.11301
    Left Arm arm angle                        : 53.172
    Tiefenbach Hall A energy                : 3399.18
    Right Arm arm mispointing (HPT)          : -1.61375
    Left Arm arm mispointing (HPT)            : 5.41035
    Right Arm Q1 power supply current        : 2104.62
    Right Arm Q1 momentum                    : 2.79894
    Right Arm Q1 gauss meter                 : -0.05228
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 1204.56
    Right Arm Q2 momentum                    : 2.79891
    Right Arm Q2 gauss meter                 : 0.6324
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 997.402
    Right Arm D1 momentum                    : 2.799
    Right Arm D1 NMR                         : 1.03867
    Right Arm Q3 power supply current        : 1114.01
    Right Arm Q3 momentum                    : 2.79965
    Right Arm Q3 gauss meter                 : 0.4995
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 837.06
    Left Arm Q1 momentum                      : 1.11262
    Left Arm Q1 gauss meter                   : 0.07157
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 479.345
    Left Arm Q2 momentum                      : 1.1132
    Left Arm Q2 gauss meter                   : -0.2529
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 371.55
    Left Arm D1 momentum                      : 1.11301
    Left Arm D1 NMR                           : 0.412049
    Left Arm Q3 power supply current          : 443.029
    Left Arm Q3 momentum                      : 1.11281
    Left Arm Q3 gauss meter                   : 0.2212
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 14.7861
    Current on Unser monitor                : 21.6037
    Current on Upstream bcm                 : 14.7859
    Current on Downstream bcm               : 14.7863
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 14.868
    MBSY1c Hall A Beam energy               : 3404.8
    MBSY1c magnet current (amp)             : 141.8
    MBSY1c Bdl                              : 849671
    MBSY3c Hall C Beam energy               : 885.574
    Tiefenbach Hall A energy                : 3399.18
    Tiefenbach Hall C energy                : 884.441
    Delta(E)/E width (MV_AI_DXWID)          : 1.19635
    IPM1C12.XPOS                            : 0.0136072
    IPM1H04A.XPOS                           : -0.12206
    IPM1H04A.YPOS                           : 0.533873
    IPM1H04B.XPOS                           : 0.0135446
    IPM1H04B.YPOS                           : 0.0329442
    Right Arm Arm Collimator                 : 0.615137
    Left Arm Arm Collimator                   : 0.616943
     HacR_HPM_LVDT:VALr                     : -1048
     HacR_VPM_LVDT:VALr                     : 147
     HacR_HPE1313A:0_Ch58                   : -0.522461
     HacR_HPE1313A:0_Ch55                   : 22.8027
     HacR_HPE1313A:0_Ch54                   : -0.825684
     HacR_alignROLL                         : -0.344776
     HacR_alignPITCH                        : -0.032057
     HacR_alignHPT                          : -1.61288
     HacL_HPM_LVDT:VALr                     : -8177
     HacL_VPM_LVDT:VALr                     : -545
     HacL_HPE1313A:0_Ch58                   : -0.293457
     HacL_HPE1313A:0_Ch55                   : 23.5352
     HacL_HPE1313A:0_Ch54                   : -0.387207
     HacL_alignROLL                         : -0.0123798
     HacL_alignPITCH                        : 0.0177423
     HacL_alignHPT                          : 5.40955
    haBDSPOS                                 : 4.643e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 69
    haL3_Fan_frequency_R                     : 37.5
    haH2_P_Fill_Target_R                     : 19.46
    haH2_P_Exhaust_R                         : 19.95
    haH2_P_Fill_Bottle_R                     : 20.04
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -720
    haD2_P_Exhaust_R                         : 17.96
    haD2_P_Fill_Bottle_R                     : 37.17
    haD2_DP_Fill_Exhaust_R                   : 0.0745
    haSC200_6_Sensor_1_R                     : 241.29
    haSC200_6_Sensor_2_R                     : 27.3
    haSC200_6_Sensor_3_R                     : 38.07
    haSC200_6_Sensor_4_R                     : 40.69
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 83.83
    haITC502_1_Sensor_2_R                    : 83.14
    haITC502_1_Sensor_3_R                    : 76.61
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 18.99
    haITC502_2_Sensor_3_R                    : 19.04
    haITC502_4_Sensor_1_R                    : 84.7
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 21.9
    haITC502_5_Sensor_1_R                    : 91.24
    haITC502_5_Sensor_2_R                    : 82.51
    haITC502_5_Sensor_3_R                    : 265.2
    haITC502_6_Sensor_1_R                    : 98.4
    haITC502_6_Sensor_2_R                    : 81.95
    haITC502_6_Sensor_3_R                    : 28.44
    Right Arm Arm Collimator                 : 0.615088
    Left Arm Arm Collimator                   : 0.616895
    Wien angle                               : 51.3832
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 1151.4
    Wien field                               : 33.611
    Laser attenuation Hall A                 : 149
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : ON