    User name adev

    Log entry time 04:01:27 on March 12, 2001

    Entry number 58510

    keyword=End_of_Run_2831
    ****************************
     Run Number: 2831
    End of Run Comment:
    RunType=pion_prod,Tar=LD2-15cm,Rad=4,comment=coin10,mode=coincidence,Lmom=1.1130,Rmom=-2.799,Ene=3.399,Angle_R=18.582,Angle_L=53.172
    
    Time of run = 9.1327312 min
    Av. current (on 3x) = 29.046806 uA
    Av. current (on 1x) = 28.956471 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|   15.8671  |   15.9166  |   15.9381
    up-down    (mC)|   -0.0860  |   -0.0419  |   -0.0135
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 33261.76 Hz  |   1145109.1 /mC  |   83.154 Hz  |  18226243  |   400   |   1148681.4 /mC
        2      | 71268.688 Hz  |   2453580.9 /mC  |   35.634 Hz  |  39052666  |  2000   |   2461235.3 /mC
        3      | 10854.977 Hz  |    373706.4 /mC  |  180.916 Hz  |   5948135  |    60   |    374872.2 /mC
        4      | 44051.596 Hz  |   1516572.8 /mC  |   44.052 Hz  |  24138683  |  1000   |   1521304.0 /mC
        5      | 1058.2285 Hz  |     36431.8 /mC  | 1058.228 Hz  |    579871  |     1   |     36545.5 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 1048.0453 Hz  |     36081.3 /mC  | 1048.045 Hz  | 574291.0  |     1   |     36193.8 /mC
        8    | 1024.0 Hz  |     35253.4 /mC  |    0.016 Hz  |    561115  | 65535   |     35363.4 /mC
        output                      1098.664 Hz
    Av. deadtime from accepted triggers = 0.2049
    Av. deadtime from gated scalers = 0.2076
    Accepted triggers  = 602028.00000
    Rate of Left Arm Pulser for electronic DT  = 10.183153
    Rate of Right Arm Pulser for electronic DT  = 0.0
    Rate of Left Arm Pulser&trig for electronic DT  = 10.181328
    Rate of Right Arm Pulser&trig for electronic DT  = 0.0
    Left Arm Electronic DT  = 0.00017921147
    Right Arm Electronic DT  = -1
    Rate of Left Strobe  = 86982.607
    Rate of Right Arm Strobe  = 109970.91
        Signal     |    Charge   (C)   
       upstream    |    0.0158241     
       upstream 3x |    0.0158956     
       upstream 10x|    0.0159313     
      downstream   |    0.0159101   
     downstream 3x |    0.0159375   
     downstream 10x|    0.0159448    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 2831 at Mon Mar 12 04:01:15 EST 2001
    Right Arm D1 momentum                    : 2.799
    Right Arm arm angle                      : 18.581
    Left Arm D1 momentum                      : 1.113
    Left Arm arm angle                        : 53.1719
    Tiefenbach Hall A energy                : 3399.18
    Right Arm arm mispointing (HPT)          : -1.59304
    Left Arm arm mispointing (HPT)            : 5.41364
    Right Arm Q1 power supply current        : 2104.55
    Right Arm Q1 momentum                    : 2.79885
    Right Arm Q1 gauss meter                 : -0.05229
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 1204.58
    Right Arm Q2 momentum                    : 2.79896
    Right Arm Q2 gauss meter                 : 0.6324
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 997.405
    Right Arm D1 momentum                    : 2.799
    Right Arm D1 NMR                         : 1.03868
    Right Arm Q3 power supply current        : 1113.58
    Right Arm Q3 momentum                    : 2.79859
    Right Arm Q3 gauss meter                 : 0.4994
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 837.165
    Left Arm Q1 momentum                      : 1.11276
    Left Arm Q1 gauss meter                   : 0.07159
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 479.163
    Left Arm Q2 momentum                      : 1.11278
    Left Arm Q2 gauss meter                   : -0.2529
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 371.548
    Left Arm D1 momentum                      : 1.113
    Left Arm D1 NMR                           : 0.412047
    Left Arm Q3 power supply current          : 443.252
    Left Arm Q3 momentum                      : 1.11337
    Left Arm Q3 gauss meter                   : 0.2213
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 29.1989
    Current on Unser monitor                : 36.0519
    Current on Upstream bcm                 : 29.0968
    Current on Downstream bcm               : 29.1531
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 29.3935
    MBSY1c Hall A Beam energy               : 3404.8
    MBSY1c magnet current (amp)             : 141.8
    MBSY1c Bdl                              : 849671
    MBSY3c Hall C Beam energy               : 885.574
    Tiefenbach Hall A energy                : 3399.18
    Tiefenbach Hall C energy                : 884.441
    Delta(E)/E width (MV_AI_DXWID)          : 1.15687
    IPM1C12.XPOS                            : 0.0035398
    IPM1H04A.XPOS                           : -0.130047
    IPM1H04A.YPOS                           : 0.481082
    IPM1H04B.XPOS                           : -0.00647161
    IPM1H04B.YPOS                           : -0.0190276
    Right Arm Arm Collimator                 : 0.615088
    Left Arm Arm Collimator                   : 0.616895
     HacR_HPM_LVDT:VALr                     : -1064
     HacR_VPM_LVDT:VALr                     : 145
     HacR_HPE1313A:0_Ch58                   : -0.521973
     HacR_HPE1313A:0_Ch55                   : 22.9004
     HacR_HPE1313A:0_Ch54                   : -0.824707
     HacR_alignROLL                         : -0.343732
     HacR_alignPITCH                        : -0.0325727
     HacR_alignHPT                          : -1.59444
     HacL_HPM_LVDT:VALr                     : -8181
     HacL_VPM_LVDT:VALr                     : -538
     HacL_HPE1313A:0_Ch58                   : -0.29248
     HacL_HPE1313A:0_Ch55                   : 23.6328
     HacL_HPE1313A:0_Ch54                   : -0.386719
     HacL_alignROLL                         : -0.012549
     HacL_alignPITCH                        : 0.0165856
     HacL_alignHPT                          : 5.41521
    haBDSPOS                                 : 3.10127e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 63
    haL3_Fan_frequency_R                     : 37
    haH2_P_Fill_Target_R                     : 19.38
    haH2_P_Exhaust_R                         : 19.88
    haH2_P_Fill_Bottle_R                     : 19.98
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -720
    haD2_P_Exhaust_R                         : 17.92
    haD2_P_Fill_Bottle_R                     : 37.14
    haD2_DP_Fill_Exhaust_R                   : 0.0743
    haSC200_6_Sensor_1_R                     : 241.68
    haSC200_6_Sensor_2_R                     : 27.55
    haSC200_6_Sensor_3_R                     : 38.37
    haSC200_6_Sensor_4_R                     : 40.89
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 83.58
    haITC502_1_Sensor_2_R                    : 82.87
    haITC502_1_Sensor_3_R                    : 77.39
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 18.99
    haITC502_2_Sensor_3_R                    : 19
    haITC502_4_Sensor_1_R                    : 84.8
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 22
    haITC502_5_Sensor_1_R                    : 91.04
    haITC502_5_Sensor_2_R                    : 82.05
    haITC502_5_Sensor_3_R                    : 266.9
    haITC502_6_Sensor_1_R                    : 98.51
    haITC502_6_Sensor_2_R                    : 82.38
    haITC502_6_Sensor_3_R                    : 28.32
    Right Arm Arm Collimator                 : 0.61499
    Left Arm Arm Collimator                   : 0.616895
    Wien angle                               : 51.3832
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 1151.4
    Wien field                               : 33.611
    Laser attenuation Hall A                 : 203
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : ON